Merge pull request #609 from MikaylaFischler/480-auxiliarybackup-water-control
480 auxiliary backup water control
This commit is contained in:
commit
122fa1a7a7
@ -164,6 +164,7 @@ function iocontrol.init(conf, comms, temp_scale, energy_scale)
|
|||||||
num_turbines = 0,
|
num_turbines = 0,
|
||||||
num_snas = 0,
|
num_snas = 0,
|
||||||
has_tank = conf.cooling.r_cool[i].TankConnection,
|
has_tank = conf.cooling.r_cool[i].TankConnection,
|
||||||
|
aux_coolant = conf.cooling.aux_coolant[i],
|
||||||
|
|
||||||
status_lines = { "", "" },
|
status_lines = { "", "" },
|
||||||
|
|
||||||
@ -1214,7 +1215,7 @@ function iocontrol.update_unit_statuses(statuses)
|
|||||||
local valve_states = status[6]
|
local valve_states = status[6]
|
||||||
|
|
||||||
if type(valve_states) == "table" then
|
if type(valve_states) == "table" then
|
||||||
if #valve_states == 5 then
|
if #valve_states == 6 then
|
||||||
unit.unit_ps.publish("V_pu_conn", valve_states[1] > 0)
|
unit.unit_ps.publish("V_pu_conn", valve_states[1] > 0)
|
||||||
unit.unit_ps.publish("V_pu_state", valve_states[1] == 2)
|
unit.unit_ps.publish("V_pu_state", valve_states[1] == 2)
|
||||||
unit.unit_ps.publish("V_po_conn", valve_states[2] > 0)
|
unit.unit_ps.publish("V_po_conn", valve_states[2] > 0)
|
||||||
@ -1225,6 +1226,8 @@ function iocontrol.update_unit_statuses(statuses)
|
|||||||
unit.unit_ps.publish("V_am_state", valve_states[4] == 2)
|
unit.unit_ps.publish("V_am_state", valve_states[4] == 2)
|
||||||
unit.unit_ps.publish("V_emc_conn", valve_states[5] > 0)
|
unit.unit_ps.publish("V_emc_conn", valve_states[5] > 0)
|
||||||
unit.unit_ps.publish("V_emc_state", valve_states[5] == 2)
|
unit.unit_ps.publish("V_emc_state", valve_states[5] == 2)
|
||||||
|
unit.unit_ps.publish("V_aux_conn", valve_states[6] > 0)
|
||||||
|
unit.unit_ps.publish("V_aux_state", valve_states[6] == 2)
|
||||||
else
|
else
|
||||||
log.debug(log_header .. "valve states length mismatch")
|
log.debug(log_header .. "valve states length mismatch")
|
||||||
valid = false
|
valid = false
|
||||||
|
|||||||
@ -19,7 +19,7 @@ local renderer = require("coordinator.renderer")
|
|||||||
local sounder = require("coordinator.sounder")
|
local sounder = require("coordinator.sounder")
|
||||||
local threads = require("coordinator.threads")
|
local threads = require("coordinator.threads")
|
||||||
|
|
||||||
local COORDINATOR_VERSION = "v1.6.8"
|
local COORDINATOR_VERSION = "v1.6.9"
|
||||||
|
|
||||||
local CHUNK_LOAD_DELAY_S = 30.0
|
local CHUNK_LOAD_DELAY_S = 30.0
|
||||||
|
|
||||||
|
|||||||
@ -59,7 +59,7 @@ local function make(parent, x, y, wide, unit_id)
|
|||||||
local tank_conns = facility.tank_conns
|
local tank_conns = facility.tank_conns
|
||||||
local tank_types = facility.tank_fluid_types
|
local tank_types = facility.tank_fluid_types
|
||||||
|
|
||||||
local v_start = 1 + ((unit.unit_id - 1) * 5)
|
local v_start = 1 + ((unit.unit_id - 1) * 6)
|
||||||
local prv_start = 1 + ((unit.unit_id - 1) * 3)
|
local prv_start = 1 + ((unit.unit_id - 1) * 3)
|
||||||
local v_fields = { "pu", "po", "pl", "am" }
|
local v_fields = { "pu", "po", "pl", "am" }
|
||||||
local v_names = {
|
local v_names = {
|
||||||
@ -94,11 +94,19 @@ local function make(parent, x, y, wide, unit_id)
|
|||||||
if unit.num_boilers > 0 then
|
if unit.num_boilers > 0 then
|
||||||
table.insert(rc_pipes, pipe(0, 1, _wide(28, 19), 1, colors.lightBlue, true))
|
table.insert(rc_pipes, pipe(0, 1, _wide(28, 19), 1, colors.lightBlue, true))
|
||||||
table.insert(rc_pipes, pipe(0, 3, _wide(28, 19), 3, colors.orange, true))
|
table.insert(rc_pipes, pipe(0, 3, _wide(28, 19), 3, colors.orange, true))
|
||||||
table.insert(rc_pipes, pipe(_wide(46 ,39), 1, _wide(72,58), 1, colors.blue, true))
|
table.insert(rc_pipes, pipe(_wide(46, 39), 1, _wide(72, 58), 1, colors.blue, true))
|
||||||
table.insert(rc_pipes, pipe(_wide(46,39), 3, _wide(72,58), 3, colors.white, true))
|
table.insert(rc_pipes, pipe(_wide(46, 39), 3, _wide(72, 58), 3, colors.white, true))
|
||||||
|
|
||||||
|
if unit.aux_coolant then
|
||||||
|
table.insert(rc_pipes, pipe(_wide(51, 41), 0, _wide(51, 41), 1, colors.blue, true))
|
||||||
|
end
|
||||||
else
|
else
|
||||||
table.insert(rc_pipes, pipe(0, 1, _wide(72,58), 1, colors.blue, true))
|
table.insert(rc_pipes, pipe(0, 1, _wide(72, 58), 1, colors.blue, true))
|
||||||
table.insert(rc_pipes, pipe(0, 3, _wide(72,58), 3, colors.white, true))
|
table.insert(rc_pipes, pipe(0, 3, _wide(72, 58), 3, colors.white, true))
|
||||||
|
|
||||||
|
if unit.aux_coolant then
|
||||||
|
table.insert(rc_pipes, pipe(8, 0, 8, 1, colors.blue, true))
|
||||||
|
end
|
||||||
end
|
end
|
||||||
|
|
||||||
if unit.has_tank then
|
if unit.has_tank then
|
||||||
|
|||||||
@ -286,7 +286,7 @@ local function init(main)
|
|||||||
|
|
||||||
TextBox{parent=main,x=12,y=vy,text="\x10\x11",fg_bg=text_col,width=2}
|
TextBox{parent=main,x=12,y=vy,text="\x10\x11",fg_bg=text_col,width=2}
|
||||||
|
|
||||||
local conn = IndicatorLight{parent=main,x=9,y=vy+1,label=util.sprintf("PV%02d-EMC", i * 5),colors=style.ind_grn}
|
local conn = IndicatorLight{parent=main,x=9,y=vy+1,label=util.sprintf("PV%02d-EMC", (i * 6) - 1),colors=style.ind_grn}
|
||||||
local open = IndicatorLight{parent=main,x=9,y=vy+2,label="OPEN",colors=style.ind_wht}
|
local open = IndicatorLight{parent=main,x=9,y=vy+2,label="OPEN",colors=style.ind_wht}
|
||||||
|
|
||||||
conn.register(units[i].unit_ps, "V_emc_conn", conn.update)
|
conn.register(units[i].unit_ps, "V_emc_conn", conn.update)
|
||||||
@ -294,6 +294,33 @@ local function init(main)
|
|||||||
end
|
end
|
||||||
end
|
end
|
||||||
|
|
||||||
|
------------------------------
|
||||||
|
-- auxiliary coolant valves --
|
||||||
|
------------------------------
|
||||||
|
|
||||||
|
for i = 1, facility.num_units do
|
||||||
|
if units[i].aux_coolant then
|
||||||
|
local vx
|
||||||
|
local vy = 3 + y_ofs(i)
|
||||||
|
|
||||||
|
if #emcool_pipes == 0 then
|
||||||
|
vx = util.trinary(units[i].num_boilers == 0, 36, 79)
|
||||||
|
else
|
||||||
|
vx = util.trinary(units[i].num_boilers == 0, 58, 91)
|
||||||
|
end
|
||||||
|
|
||||||
|
PipeNetwork{parent=main,x=vx-6,y=vy,pipes={pipe(0,1,9,0,colors.blue,true)},bg=style.theme.bg}
|
||||||
|
|
||||||
|
TextBox{parent=main,x=vx,y=vy,text="\x10\x11",fg_bg=text_col,width=2}
|
||||||
|
|
||||||
|
local conn = IndicatorLight{parent=main,x=vx-3,y=vy+1,label=util.sprintf("PV%02d-AUX", i * 6),colors=style.ind_grn}
|
||||||
|
local open = IndicatorLight{parent=main,x=vx-3,y=vy+2,label="OPEN",colors=style.ind_wht}
|
||||||
|
|
||||||
|
conn.register(units[i].unit_ps, "V_aux_conn", conn.update)
|
||||||
|
open.register(units[i].unit_ps, "V_aux_state", open.update)
|
||||||
|
end
|
||||||
|
end
|
||||||
|
|
||||||
-------------------
|
-------------------
|
||||||
-- dynamic tanks --
|
-- dynamic tanks --
|
||||||
-------------------
|
-------------------
|
||||||
|
|||||||
@ -74,11 +74,12 @@ local PORT_DESC_MAP = {
|
|||||||
{ IO.R_PLC_FAULT, "RPS PLC Fault" },
|
{ IO.R_PLC_FAULT, "RPS PLC Fault" },
|
||||||
{ IO.R_PLC_TIMEOUT, "RPS Supervisor Timeout" },
|
{ IO.R_PLC_TIMEOUT, "RPS Supervisor Timeout" },
|
||||||
{ IO.U_ALARM, "Unit Alarm" },
|
{ IO.U_ALARM, "Unit Alarm" },
|
||||||
{ IO.U_EMER_COOL, "Unit Emergency Cool. Valve" }
|
{ IO.U_EMER_COOL, "Unit Emergency Cool. Valve" },
|
||||||
|
{ IO.U_AUX_COOL, "Unit Auxiliary Cool. Valve" }
|
||||||
}
|
}
|
||||||
|
|
||||||
-- designation (0 = facility, 1 = unit)
|
-- designation (0 = facility, 1 = unit)
|
||||||
local PORT_DSGN = { [-1] = 1, 0, 0, 1, 1, 1, 1, 0, 0, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 0, 0, 0 }
|
local PORT_DSGN = { [-1] = 1, 0, 0, 1, 1, 1, 1, 0, 0, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 0, 0, 0, 1 }
|
||||||
|
|
||||||
assert(#PORT_DESC_MAP == rsio.NUM_PORTS)
|
assert(#PORT_DESC_MAP == rsio.NUM_PORTS)
|
||||||
assert(#PORT_DSGN == rsio.NUM_PORTS)
|
assert(#PORT_DSGN == rsio.NUM_PORTS)
|
||||||
|
|||||||
@ -31,7 +31,7 @@ local sna_rtu = require("rtu.dev.sna_rtu")
|
|||||||
local sps_rtu = require("rtu.dev.sps_rtu")
|
local sps_rtu = require("rtu.dev.sps_rtu")
|
||||||
local turbinev_rtu = require("rtu.dev.turbinev_rtu")
|
local turbinev_rtu = require("rtu.dev.turbinev_rtu")
|
||||||
|
|
||||||
local RTU_VERSION = "v1.11.4"
|
local RTU_VERSION = "v1.11.5"
|
||||||
|
|
||||||
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
|
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
|
||||||
local RTU_HW_STATE = databus.RTU_HW_STATE
|
local RTU_HW_STATE = databus.RTU_HW_STATE
|
||||||
|
|||||||
@ -72,6 +72,8 @@ local rs = {}
|
|||||||
|
|
||||||
rs.IMATRIX_CHARGE_LOW = 0.05 -- activation threshold (less than) for F_MATRIX_LOW
|
rs.IMATRIX_CHARGE_LOW = 0.05 -- activation threshold (less than) for F_MATRIX_LOW
|
||||||
rs.IMATRIX_CHARGE_HIGH = 0.95 -- activation threshold (greater than) for F_MATRIX_HIGH
|
rs.IMATRIX_CHARGE_HIGH = 0.95 -- activation threshold (greater than) for F_MATRIX_HIGH
|
||||||
|
rs.AUX_COOL_ENABLE = 0.60 -- actiation threshold (less than or equal) for U_AUX_COOL
|
||||||
|
rs.AUX_COOL_DISABLE = 1.00 -- deactivation threshold (greater than or equal) for U_AUX_COOL
|
||||||
|
|
||||||
constants.RS_THRESHOLDS = rs
|
constants.RS_THRESHOLDS = rs
|
||||||
|
|
||||||
|
|||||||
@ -78,6 +78,7 @@ local IO_PORT = {
|
|||||||
-- unit outputs
|
-- unit outputs
|
||||||
U_ALARM = 25, -- active high, unit alarm
|
U_ALARM = 25, -- active high, unit alarm
|
||||||
U_EMER_COOL = 26, -- active low, emergency coolant control
|
U_EMER_COOL = 26, -- active low, emergency coolant control
|
||||||
|
U_AUX_COOL = 30, -- active low, auxiliary coolant control
|
||||||
|
|
||||||
-- analog outputs --
|
-- analog outputs --
|
||||||
|
|
||||||
@ -90,8 +91,8 @@ rsio.IO_DIR = IO_DIR
|
|||||||
rsio.IO_MODE = IO_MODE
|
rsio.IO_MODE = IO_MODE
|
||||||
rsio.IO = IO_PORT
|
rsio.IO = IO_PORT
|
||||||
|
|
||||||
rsio.NUM_PORTS = 29
|
rsio.NUM_PORTS = 30
|
||||||
rsio.NUM_DIG_PORTS = 28
|
rsio.NUM_DIG_PORTS = 29
|
||||||
rsio.NUM_ANA_PORTS = 1
|
rsio.NUM_ANA_PORTS = 1
|
||||||
|
|
||||||
-- self checks
|
-- self checks
|
||||||
@ -149,6 +150,7 @@ local MODES = {
|
|||||||
[IO.R_PLC_TIMEOUT] = IO_MODE.DIGITAL_OUT,
|
[IO.R_PLC_TIMEOUT] = IO_MODE.DIGITAL_OUT,
|
||||||
[IO.U_ALARM] = IO_MODE.DIGITAL_OUT,
|
[IO.U_ALARM] = IO_MODE.DIGITAL_OUT,
|
||||||
[IO.U_EMER_COOL] = IO_MODE.DIGITAL_OUT,
|
[IO.U_EMER_COOL] = IO_MODE.DIGITAL_OUT,
|
||||||
|
[IO.U_AUX_COOL] = IO_MODE.DIGITAL_OUT,
|
||||||
[IO.F_MATRIX_CHG] = IO_MODE.ANALOG_OUT
|
[IO.F_MATRIX_CHG] = IO_MODE.ANALOG_OUT
|
||||||
}
|
}
|
||||||
|
|
||||||
@ -208,10 +210,11 @@ local RS_DIO_MAP = {
|
|||||||
[IO.R_PLC_TIMEOUT] = { _in = _I_ACTIVE_HIGH, _out = _O_ACTIVE_HIGH, mode = IO_DIR.OUT },
|
[IO.R_PLC_TIMEOUT] = { _in = _I_ACTIVE_HIGH, _out = _O_ACTIVE_HIGH, mode = IO_DIR.OUT },
|
||||||
|
|
||||||
[IO.U_ALARM] = { _in = _I_ACTIVE_HIGH, _out = _O_ACTIVE_HIGH, mode = IO_DIR.OUT },
|
[IO.U_ALARM] = { _in = _I_ACTIVE_HIGH, _out = _O_ACTIVE_HIGH, mode = IO_DIR.OUT },
|
||||||
[IO.U_EMER_COOL] = { _in = _I_ACTIVE_LOW, _out = _O_ACTIVE_LOW, mode = IO_DIR.OUT }
|
[IO.U_EMER_COOL] = { _in = _I_ACTIVE_LOW, _out = _O_ACTIVE_LOW, mode = IO_DIR.OUT },
|
||||||
|
[IO.U_AUX_COOL] = { _in = _I_ACTIVE_LOW, _out = _O_ACTIVE_LOW, mode = IO_DIR.OUT }
|
||||||
}
|
}
|
||||||
|
|
||||||
assert(rsio.NUM_DIG_PORTS == #RS_DIO_MAP, "RS_DIO_MAP length incorrect")
|
assert(rsio.NUM_DIG_PORTS == util.table_len(RS_DIO_MAP), "RS_DIO_MAP length incorrect")
|
||||||
|
|
||||||
-- get the I/O direction of a port
|
-- get the I/O direction of a port
|
||||||
---@nodiscard
|
---@nodiscard
|
||||||
|
|||||||
@ -24,7 +24,7 @@ local t_pack = table.pack
|
|||||||
local util = {}
|
local util = {}
|
||||||
|
|
||||||
-- scada-common version
|
-- scada-common version
|
||||||
util.version = "1.4.10"
|
util.version = "1.4.12"
|
||||||
|
|
||||||
util.TICK_TIME_S = 0.05
|
util.TICK_TIME_S = 0.05
|
||||||
util.TICK_TIME_MS = 50
|
util.TICK_TIME_MS = 50
|
||||||
|
|||||||
@ -185,8 +185,9 @@ function facility.create(tool_ctl, main_pane, cfg_sys, fac_cfg, style)
|
|||||||
local fac_c_6 = Div{parent=fac_cfg,x=2,y=4,width=49}
|
local fac_c_6 = Div{parent=fac_cfg,x=2,y=4,width=49}
|
||||||
local fac_c_7 = Div{parent=fac_cfg,x=2,y=4,width=49}
|
local fac_c_7 = Div{parent=fac_cfg,x=2,y=4,width=49}
|
||||||
local fac_c_8 = Div{parent=fac_cfg,x=2,y=4,width=49}
|
local fac_c_8 = Div{parent=fac_cfg,x=2,y=4,width=49}
|
||||||
|
local fac_c_9 = Div{parent=fac_cfg,x=2,y=4,width=49}
|
||||||
|
|
||||||
local fac_pane = MultiPane{parent=fac_cfg,x=1,y=4,panes={fac_c_1,fac_c_2,fac_c_3,fac_c_4,fac_c_5,fac_c_6,fac_c_7, fac_c_8}}
|
local fac_pane = MultiPane{parent=fac_cfg,x=1,y=4,panes={fac_c_1,fac_c_2,fac_c_3,fac_c_4,fac_c_5,fac_c_6,fac_c_7,fac_c_8,fac_c_9}}
|
||||||
|
|
||||||
TextBox{parent=fac_cfg,x=1,y=2,text=" Facility Configuration",fg_bg=cpair(colors.black,colors.yellow)}
|
TextBox{parent=fac_cfg,x=1,y=2,text=" Facility Configuration",fg_bg=cpair(colors.black,colors.yellow)}
|
||||||
|
|
||||||
@ -205,10 +206,18 @@ function facility.create(tool_ctl, main_pane, cfg_sys, fac_cfg, style)
|
|||||||
nu_error.hide(true)
|
nu_error.hide(true)
|
||||||
tmp_cfg.UnitCount = count
|
tmp_cfg.UnitCount = count
|
||||||
|
|
||||||
local confs = tool_ctl.cooling_elems
|
local c_confs = tool_ctl.cooling_elems
|
||||||
if count >= 2 then confs[2].line.show() else confs[2].line.hide(true) end
|
local a_confs = tool_ctl.aux_cool_elems
|
||||||
if count >= 3 then confs[3].line.show() else confs[3].line.hide(true) end
|
|
||||||
if count == 4 then confs[4].line.show() else confs[4].line.hide(true) end
|
for i = 2, 4 do
|
||||||
|
if count >= i then
|
||||||
|
c_confs[i].line.show()
|
||||||
|
a_confs[i].line.show()
|
||||||
|
else
|
||||||
|
c_confs[i].line.hide(true)
|
||||||
|
a_confs[i].line.hide(true)
|
||||||
|
end
|
||||||
|
end
|
||||||
|
|
||||||
fac_pane.set_value(2)
|
fac_pane.set_value(2)
|
||||||
else nu_error.show() end
|
else nu_error.show() end
|
||||||
@ -285,6 +294,14 @@ function facility.create(tool_ctl, main_pane, cfg_sys, fac_cfg, style)
|
|||||||
else elem.div.hide(true) end
|
else elem.div.hide(true) end
|
||||||
end
|
end
|
||||||
|
|
||||||
|
if not any_has_tank then
|
||||||
|
tmp_cfg.FacilityTankMode = 0
|
||||||
|
tmp_cfg.FacilityTankDefs = {}
|
||||||
|
tmp_cfg.FacilityTankList = {}
|
||||||
|
tmp_cfg.FacilityTankConns = {}
|
||||||
|
tmp_cfg.TankFluidTypes = {}
|
||||||
|
end
|
||||||
|
|
||||||
if any_has_tank then fac_pane.set_value(3) else main_pane.set_value(3) end
|
if any_has_tank then fac_pane.set_value(3) else main_pane.set_value(3) end
|
||||||
end
|
end
|
||||||
end
|
end
|
||||||
@ -672,25 +689,48 @@ function facility.create(tool_ctl, main_pane, cfg_sys, fac_cfg, style)
|
|||||||
PushButton{parent=fac_c_7,x=1,y=14,text="\x1b Back",callback=back_from_fluids,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
PushButton{parent=fac_c_7,x=1,y=14,text="\x1b Back",callback=back_from_fluids,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||||
PushButton{parent=fac_c_7,x=44,y=14,text="Next \x1a",callback=submit_tank_fluids,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
PushButton{parent=fac_c_7,x=44,y=14,text="Next \x1a",callback=submit_tank_fluids,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||||
|
|
||||||
|
--#endregion
|
||||||
|
--#region Auxiliary Coolant
|
||||||
|
|
||||||
|
TextBox{parent=fac_c_8,height=5,text="Auxiliary water coolant can be enabled for units to provide extra water during turbine ramp-up. For water cooled reactors, this goes to the reactor. For sodium cooled reactors, water goes to the boiler."}
|
||||||
|
|
||||||
|
for i = 1, 4 do
|
||||||
|
local line = Div{parent=fac_c_8,x=1,y=7+i,height=1}
|
||||||
|
|
||||||
|
TextBox{parent=line,text="Unit "..i.." -",width=8}
|
||||||
|
local aux_cool = Checkbox{parent=line,x=10,y=1,label="Has Auxiliary Coolant",default=ini_cfg.AuxiliaryCoolant[i],box_fg_bg=cpair(colors.yellow,colors.black)}
|
||||||
|
|
||||||
|
tool_ctl.aux_cool_elems[i] = { line = line, enable = aux_cool }
|
||||||
|
end
|
||||||
|
|
||||||
|
local function submit_aux_cool()
|
||||||
|
tmp_cfg.AuxiliaryCoolant = {}
|
||||||
|
|
||||||
|
for i = 1, tmp_cfg.UnitCount do
|
||||||
|
tmp_cfg.AuxiliaryCoolant[i] = tool_ctl.aux_cool_elems[i].enable.get_value()
|
||||||
|
end
|
||||||
|
|
||||||
|
fac_pane.set_value(9)
|
||||||
|
end
|
||||||
|
|
||||||
|
PushButton{parent=fac_c_8,x=1,y=14,text="\x1b Back",callback=function()fac_pane.set_value(7)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||||
|
PushButton{parent=fac_c_8,x=44,y=14,text="Next \x1a",callback=submit_aux_cool,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||||
|
|
||||||
--#endregion
|
--#endregion
|
||||||
--#region Extended Idling
|
--#region Extended Idling
|
||||||
|
|
||||||
TextBox{parent=fac_c_8,height=6,text="Charge control provides automatic control to maintain an induction matrix charge level. In order to have smoother control, reactors that were activated will be held on at 0.01 mB/t for a short period before allowing them to turn off. This minimizes overshooting the charge target."}
|
TextBox{parent=fac_c_9,height=6,text="Charge control provides automatic control to maintain an induction matrix charge level. In order to have smoother control, reactors that were activated will be held on at 0.01 mB/t for a short period before allowing them to turn off. This minimizes overshooting the charge target."}
|
||||||
TextBox{parent=fac_c_8,y=8,height=3,text="You can extend this to a full minute to minimize reactors flickering on/off, but there may be more overshoot of the target."}
|
TextBox{parent=fac_c_9,y=8,height=3,text="You can extend this to a full minute to minimize reactors flickering on/off, but there may be more overshoot of the target."}
|
||||||
|
|
||||||
local ext_idling = Checkbox{parent=fac_c_8,x=1,y=12,label="Enable Extended Idling",default=ini_cfg.ExtChargeIdling,box_fg_bg=cpair(colors.yellow,colors.black)}
|
local ext_idling = Checkbox{parent=fac_c_9,x=1,y=12,label="Enable Extended Idling",default=ini_cfg.ExtChargeIdling,box_fg_bg=cpair(colors.yellow,colors.black)}
|
||||||
|
|
||||||
local function back_from_idling()
|
|
||||||
fac_pane.set_value(tri(tmp_cfg.FacilityTankMode == 0, 3, 7))
|
|
||||||
end
|
|
||||||
|
|
||||||
local function submit_idling()
|
local function submit_idling()
|
||||||
tmp_cfg.ExtChargeIdling = ext_idling.get_value()
|
tmp_cfg.ExtChargeIdling = ext_idling.get_value()
|
||||||
main_pane.set_value(3)
|
main_pane.set_value(3)
|
||||||
end
|
end
|
||||||
|
|
||||||
PushButton{parent=fac_c_8,x=1,y=14,text="\x1b Back",callback=back_from_idling,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
PushButton{parent=fac_c_9,x=1,y=14,text="\x1b Back",callback=function()fac_pane.set_value(8)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||||
PushButton{parent=fac_c_8,x=44,y=14,text="Next \x1a",callback=submit_idling,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
PushButton{parent=fac_c_9,x=44,y=14,text="Next \x1a",callback=submit_idling,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||||
|
|
||||||
--#endregion
|
--#endregion
|
||||||
|
|
||||||
|
|||||||
@ -402,6 +402,10 @@ function system.create(tool_ctl, main_pane, cfg_sys, divs, fac_pane, style, exit
|
|||||||
try_set(tool_ctl.tank_elems[i].tank_opt, ini_cfg.FacilityTankDefs[i])
|
try_set(tool_ctl.tank_elems[i].tank_opt, ini_cfg.FacilityTankDefs[i])
|
||||||
end
|
end
|
||||||
|
|
||||||
|
for i = 1, #ini_cfg.AuxiliaryCoolant do
|
||||||
|
try_set(tool_ctl.aux_cool_elems[i].enable, ini_cfg.AuxiliaryCoolant[i])
|
||||||
|
end
|
||||||
|
|
||||||
tool_ctl.en_fac_tanks.set_value(ini_cfg.FacilityTankMode > 0)
|
tool_ctl.en_fac_tanks.set_value(ini_cfg.FacilityTankMode > 0)
|
||||||
|
|
||||||
tool_ctl.view_cfg.enable()
|
tool_ctl.view_cfg.enable()
|
||||||
@ -588,7 +592,7 @@ function system.create(tool_ctl, main_pane, cfg_sys, divs, fac_pane, style, exit
|
|||||||
end
|
end
|
||||||
|
|
||||||
if val == "" then val = "no facility tanks" end
|
if val == "" then val = "no facility tanks" end
|
||||||
elseif f[1] == "FacilityTankMode" and raw == 0 then val = "0 (n/a, unit mode)"
|
elseif f[1] == "FacilityTankMode" and raw == 0 then val = "no facility tanks"
|
||||||
elseif f[1] == "FacilityTankDefs" and type(cfg.FacilityTankDefs) == "table" then
|
elseif f[1] == "FacilityTankDefs" and type(cfg.FacilityTankDefs) == "table" then
|
||||||
local tank_name_list = { table.unpack(cfg.FacilityTankList) } ---@type (string|integer)[]
|
local tank_name_list = { table.unpack(cfg.FacilityTankList) } ---@type (string|integer)[]
|
||||||
local next_f = 1
|
local next_f = 1
|
||||||
@ -647,6 +651,16 @@ function system.create(tool_ctl, main_pane, cfg_sys, divs, fac_pane, style, exit
|
|||||||
end
|
end
|
||||||
|
|
||||||
if val == "" then val = "no emergency coolant tanks" end
|
if val == "" then val = "no emergency coolant tanks" end
|
||||||
|
elseif f[1] == "AuxiliaryCoolant" then
|
||||||
|
val = ""
|
||||||
|
|
||||||
|
for idx = 1, #cfg.AuxiliaryCoolant do
|
||||||
|
if cfg.AuxiliaryCoolant[idx] then
|
||||||
|
val = val .. tri(val == "", "", "\n") .. util.sprintf(" \x07 auxiliary coolant for unit %d", idx)
|
||||||
|
end
|
||||||
|
end
|
||||||
|
|
||||||
|
if val == "" then val = "no auxiliary coolant" end
|
||||||
end
|
end
|
||||||
|
|
||||||
if not skip then
|
if not skip then
|
||||||
|
|||||||
@ -72,7 +72,8 @@ local tool_ctl = {
|
|||||||
load_legacy = nil, ---@type function
|
load_legacy = nil, ---@type function
|
||||||
|
|
||||||
cooling_elems = {}, ---@type { line: Div, turbines: NumberField, boilers: NumberField, tank: Checkbox }[]
|
cooling_elems = {}, ---@type { line: Div, turbines: NumberField, boilers: NumberField, tank: Checkbox }[]
|
||||||
tank_elems = {} ---@type { div: Div, tank_opt: Radio2D, no_tank: TextBox }[]
|
tank_elems = {}, ---@type { div: Div, tank_opt: Radio2D, no_tank: TextBox }[]
|
||||||
|
aux_cool_elems = {} ---@type { line: Div, enable: Checkbox }[]
|
||||||
}
|
}
|
||||||
|
|
||||||
---@class svr_config
|
---@class svr_config
|
||||||
@ -84,6 +85,7 @@ local tmp_cfg = {
|
|||||||
FacilityTankList = {}, ---@type integer[] list of tanks by slot (0 = none or covered by an above tank, 1 = unit tank, 2 = facility tank)
|
FacilityTankList = {}, ---@type integer[] list of tanks by slot (0 = none or covered by an above tank, 1 = unit tank, 2 = facility tank)
|
||||||
FacilityTankConns = {}, ---@type integer[] map of unit tank connections (indicies are units, values are tank indicies in the tank list)
|
FacilityTankConns = {}, ---@type integer[] map of unit tank connections (indicies are units, values are tank indicies in the tank list)
|
||||||
TankFluidTypes = {}, ---@type integer[] which type of fluid each tank in the tank list should be containing
|
TankFluidTypes = {}, ---@type integer[] which type of fluid each tank in the tank list should be containing
|
||||||
|
AuxiliaryCoolant = {}, ---@type boolean[] if a unit has auxiliary coolant
|
||||||
ExtChargeIdling = false,
|
ExtChargeIdling = false,
|
||||||
SVR_Channel = nil, ---@type integer
|
SVR_Channel = nil, ---@type integer
|
||||||
PLC_Channel = nil, ---@type integer
|
PLC_Channel = nil, ---@type integer
|
||||||
@ -117,6 +119,7 @@ local fields = {
|
|||||||
{ "FacilityTankList", "Facility Tank List", {} }, -- hidden
|
{ "FacilityTankList", "Facility Tank List", {} }, -- hidden
|
||||||
{ "FacilityTankConns", "Facility Tank Connections", {} }, -- hidden
|
{ "FacilityTankConns", "Facility Tank Connections", {} }, -- hidden
|
||||||
{ "TankFluidTypes", "Tank Fluid Types", {} },
|
{ "TankFluidTypes", "Tank Fluid Types", {} },
|
||||||
|
{ "AuxiliaryCoolant", "Auxiliary Water Coolant", {} },
|
||||||
{ "ExtChargeIdling", "Extended Charge Idling", false },
|
{ "ExtChargeIdling", "Extended Charge Idling", false },
|
||||||
{ "SVR_Channel", "SVR Channel", 16240 },
|
{ "SVR_Channel", "SVR Channel", 16240 },
|
||||||
{ "PLC_Channel", "PLC Channel", 16241 },
|
{ "PLC_Channel", "PLC Channel", 16241 },
|
||||||
|
|||||||
@ -64,7 +64,8 @@ function facility.new(config)
|
|||||||
fac_tank_defs = config.FacilityTankDefs,
|
fac_tank_defs = config.FacilityTankDefs,
|
||||||
fac_tank_list = config.FacilityTankList,
|
fac_tank_list = config.FacilityTankList,
|
||||||
fac_tank_conns = config.FacilityTankConns,
|
fac_tank_conns = config.FacilityTankConns,
|
||||||
tank_fluid_types = config.TankFluidTypes
|
tank_fluid_types = config.TankFluidTypes,
|
||||||
|
aux_coolant = config.AuxiliaryCoolant
|
||||||
},
|
},
|
||||||
-- rtus
|
-- rtus
|
||||||
rtu_gw_conn_count = 0,
|
rtu_gw_conn_count = 0,
|
||||||
@ -147,7 +148,7 @@ function facility.new(config)
|
|||||||
|
|
||||||
-- create units
|
-- create units
|
||||||
for i = 1, config.UnitCount do
|
for i = 1, config.UnitCount do
|
||||||
table.insert(self.units, unit.new(i, self.cooling_conf.r_cool[i].BoilerCount, self.cooling_conf.r_cool[i].TurbineCount, config.ExtChargeIdling))
|
table.insert(self.units, unit.new(i, self.cooling_conf.r_cool[i].BoilerCount, self.cooling_conf.r_cool[i].TurbineCount, config.ExtChargeIdling, self.cooling_conf.aux_coolant[i]))
|
||||||
table.insert(self.group_map, AUTO_GROUP.MANUAL)
|
table.insert(self.group_map, AUTO_GROUP.MANUAL)
|
||||||
table.insert(self.last_unit_states, false)
|
table.insert(self.last_unit_states, false)
|
||||||
end
|
end
|
||||||
|
|||||||
@ -10,6 +10,7 @@ local log = require("scada-common.log")
|
|||||||
local network = require("scada-common.network")
|
local network = require("scada-common.network")
|
||||||
local ppm = require("scada-common.ppm")
|
local ppm = require("scada-common.ppm")
|
||||||
local tcd = require("scada-common.tcd")
|
local tcd = require("scada-common.tcd")
|
||||||
|
local types = require("scada-common.types")
|
||||||
local util = require("scada-common.util")
|
local util = require("scada-common.util")
|
||||||
|
|
||||||
local core = require("graphics.core")
|
local core = require("graphics.core")
|
||||||
@ -22,7 +23,7 @@ local supervisor = require("supervisor.supervisor")
|
|||||||
|
|
||||||
local svsessions = require("supervisor.session.svsessions")
|
local svsessions = require("supervisor.session.svsessions")
|
||||||
|
|
||||||
local SUPERVISOR_VERSION = "v1.6.6"
|
local SUPERVISOR_VERSION = "v1.6.7"
|
||||||
|
|
||||||
local println = util.println
|
local println = util.println
|
||||||
local println_ts = util.println_ts
|
local println_ts = util.println_ts
|
||||||
@ -72,6 +73,21 @@ if config.FacilityTankMode > 0 then
|
|||||||
cfv.assert_type_int(def)
|
cfv.assert_type_int(def)
|
||||||
cfv.assert_range(def, 0, 2)
|
cfv.assert_range(def, 0, 2)
|
||||||
assert(cfv.valid(), "startup> invalid facility tank definition for reactor unit " .. i)
|
assert(cfv.valid(), "startup> invalid facility tank definition for reactor unit " .. i)
|
||||||
|
|
||||||
|
local entry = config.FacilityTankList[i]
|
||||||
|
cfv.assert_type_int(entry)
|
||||||
|
cfv.assert_range(entry, 0, 2)
|
||||||
|
assert(cfv.valid(), "startup> invalid facility tank list entry for tank " .. i)
|
||||||
|
|
||||||
|
local conn = config.FacilityTankConns[i]
|
||||||
|
cfv.assert_type_int(conn)
|
||||||
|
cfv.assert_range(conn, 0, #config.FacilityTankDefs)
|
||||||
|
assert(cfv.valid(), "startup> invalid facility tank connection for reactor unit " .. i)
|
||||||
|
|
||||||
|
local type = config.TankFluidTypes[i]
|
||||||
|
cfv.assert_type_int(type)
|
||||||
|
cfv.assert_range(type, 0, types.COOLANT_TYPE.SODIUM)
|
||||||
|
assert(cfv.valid(), "startup> invalid tank fluid type for tank " .. i)
|
||||||
end
|
end
|
||||||
end
|
end
|
||||||
|
|
||||||
|
|||||||
@ -44,6 +44,7 @@ function supervisor.load_config()
|
|||||||
config.FacilityTankList = settings.get("FacilityTankList")
|
config.FacilityTankList = settings.get("FacilityTankList")
|
||||||
config.FacilityTankConns = settings.get("FacilityTankConns")
|
config.FacilityTankConns = settings.get("FacilityTankConns")
|
||||||
config.TankFluidTypes = settings.get("TankFluidTypes")
|
config.TankFluidTypes = settings.get("TankFluidTypes")
|
||||||
|
config.AuxiliaryCoolant = settings.get("AuxiliaryCoolant")
|
||||||
config.ExtChargeIdling = settings.get("ExtChargeIdling")
|
config.ExtChargeIdling = settings.get("ExtChargeIdling")
|
||||||
|
|
||||||
config.SVR_Channel = settings.get("SVR_Channel")
|
config.SVR_Channel = settings.get("SVR_Channel")
|
||||||
@ -78,6 +79,7 @@ function supervisor.load_config()
|
|||||||
cfv.assert_type_table(config.FacilityTankList)
|
cfv.assert_type_table(config.FacilityTankList)
|
||||||
cfv.assert_type_table(config.FacilityTankConns)
|
cfv.assert_type_table(config.FacilityTankConns)
|
||||||
cfv.assert_type_table(config.TankFluidTypes)
|
cfv.assert_type_table(config.TankFluidTypes)
|
||||||
|
cfv.assert_type_table(config.AuxiliaryCoolant)
|
||||||
cfv.assert_range(config.FacilityTankMode, 0, 8)
|
cfv.assert_range(config.FacilityTankMode, 0, 8)
|
||||||
|
|
||||||
cfv.assert_type_bool(config.ExtChargeIdling)
|
cfv.assert_type_bool(config.ExtChargeIdling)
|
||||||
|
|||||||
@ -66,7 +66,8 @@ local unit = {}
|
|||||||
---@param num_boilers integer number of boilers expected
|
---@param num_boilers integer number of boilers expected
|
||||||
---@param num_turbines integer number of turbines expected
|
---@param num_turbines integer number of turbines expected
|
||||||
---@param ext_idle boolean extended idling mode
|
---@param ext_idle boolean extended idling mode
|
||||||
function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
---@param aux_coolant boolean if this unit has auxiliary coolant
|
||||||
|
function unit.new(reactor_id, num_boilers, num_turbines, ext_idle, aux_coolant)
|
||||||
-- time (ms) to idle for auto idling
|
-- time (ms) to idle for auto idling
|
||||||
local IDLE_TIME = util.trinary(ext_idle, 60000, 10000)
|
local IDLE_TIME = util.trinary(ext_idle, 60000, 10000)
|
||||||
|
|
||||||
@ -79,6 +80,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
|||||||
plc_i = nil, ---@type plc_session
|
plc_i = nil, ---@type plc_session
|
||||||
num_boilers = num_boilers,
|
num_boilers = num_boilers,
|
||||||
num_turbines = num_turbines,
|
num_turbines = num_turbines,
|
||||||
|
aux_coolant = aux_coolant,
|
||||||
types = { DT_KEYS = DT_KEYS, AISTATE = AISTATE },
|
types = { DT_KEYS = DT_KEYS, AISTATE = AISTATE },
|
||||||
-- rtus
|
-- rtus
|
||||||
rtu_list = {}, ---@type unit_session[][]
|
rtu_list = {}, ---@type unit_session[][]
|
||||||
@ -92,7 +94,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
|||||||
io_ctl = nil, ---@type rs_controller
|
io_ctl = nil, ---@type rs_controller
|
||||||
---@diagnostic disable-next-line: missing-fields
|
---@diagnostic disable-next-line: missing-fields
|
||||||
valves = {}, ---@type unit_valves
|
valves = {}, ---@type unit_valves
|
||||||
emcool_opened = false,
|
em_cool_opened = false,
|
||||||
|
aux_cool_opened = false,
|
||||||
-- auto control
|
-- auto control
|
||||||
auto_engaged = false,
|
auto_engaged = false,
|
||||||
auto_idle = false,
|
auto_idle = false,
|
||||||
@ -111,6 +114,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
|||||||
damage_est_last = 0,
|
damage_est_last = 0,
|
||||||
waste_product = WASTE.PLUTONIUM, ---@type WASTE_PRODUCT
|
waste_product = WASTE.PLUTONIUM, ---@type WASTE_PRODUCT
|
||||||
status_text = { "UNKNOWN", "awaiting connection..." },
|
status_text = { "UNKNOWN", "awaiting connection..." },
|
||||||
|
enable_aux_cool = false,
|
||||||
-- logic for alarms
|
-- logic for alarms
|
||||||
had_reactor = false,
|
had_reactor = false,
|
||||||
turbine_flow_stable = false,
|
turbine_flow_stable = false,
|
||||||
@ -373,6 +377,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
|||||||
local waste_po = _make_valve_iface(IO.WASTE_POPL)
|
local waste_po = _make_valve_iface(IO.WASTE_POPL)
|
||||||
local waste_sps = _make_valve_iface(IO.WASTE_AM)
|
local waste_sps = _make_valve_iface(IO.WASTE_AM)
|
||||||
local emer_cool = _make_valve_iface(IO.U_EMER_COOL)
|
local emer_cool = _make_valve_iface(IO.U_EMER_COOL)
|
||||||
|
local aux_cool = _make_valve_iface(IO.U_AUX_COOL)
|
||||||
|
|
||||||
---@class unit_valves
|
---@class unit_valves
|
||||||
self.valves = {
|
self.valves = {
|
||||||
@ -380,7 +385,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
|||||||
waste_sna = waste_sna,
|
waste_sna = waste_sna,
|
||||||
waste_po = waste_po,
|
waste_po = waste_po,
|
||||||
waste_sps = waste_sps,
|
waste_sps = waste_sps,
|
||||||
emer_cool = emer_cool
|
emer_cool = emer_cool,
|
||||||
|
aux_cool = aux_cool
|
||||||
}
|
}
|
||||||
|
|
||||||
-- route reactor waste for a given waste product
|
-- route reactor waste for a given waste product
|
||||||
@ -606,7 +612,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
|||||||
if #self.redstone > 0 then
|
if #self.redstone > 0 then
|
||||||
logic.handle_redstone(self)
|
logic.handle_redstone(self)
|
||||||
elseif not self.plc_cache.rps_trip then
|
elseif not self.plc_cache.rps_trip then
|
||||||
self.emcool_opened = false
|
self.em_cool_opened = false
|
||||||
end
|
end
|
||||||
end
|
end
|
||||||
|
|
||||||
@ -724,7 +730,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
|||||||
|
|
||||||
-- queue a command to clear timeout/auto-scram if set
|
-- queue a command to clear timeout/auto-scram if set
|
||||||
function public.auto_cond_rps_reset()
|
function public.auto_cond_rps_reset()
|
||||||
if self.plc_s ~= nil and self.plc_i ~= nil and (not self.auto_was_alarmed) and (not self.emcool_opened) then
|
if self.plc_s ~= nil and self.plc_i ~= nil and (not self.auto_was_alarmed) and (not self.em_cool_opened) then
|
||||||
local rps = self.plc_i.get_rps()
|
local rps = self.plc_i.get_rps()
|
||||||
if rps.timeout or rps.automatic then
|
if rps.timeout or rps.automatic then
|
||||||
self.plc_i.auto_lock(true) -- if it timed out/restarted, auto lock was lost, so re-lock it
|
self.plc_i.auto_lock(true) -- if it timed out/restarted, auto lock was lost, so re-lock it
|
||||||
@ -865,7 +871,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
|||||||
|
|
||||||
-- check if emergency coolant activation has been tripped
|
-- check if emergency coolant activation has been tripped
|
||||||
---@nodiscard
|
---@nodiscard
|
||||||
function public.is_emer_cool_tripped() return self.emcool_opened end
|
function public.is_emer_cool_tripped() return self.em_cool_opened end
|
||||||
|
|
||||||
-- get build properties of machines
|
-- get build properties of machines
|
||||||
--
|
--
|
||||||
@ -1059,7 +1065,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
|||||||
v.waste_sna.check(),
|
v.waste_sna.check(),
|
||||||
v.waste_po.check(),
|
v.waste_po.check(),
|
||||||
v.waste_sps.check(),
|
v.waste_sps.check(),
|
||||||
v.emer_cool.check()
|
v.emer_cool.check(),
|
||||||
|
v.aux_cool.check()
|
||||||
}
|
}
|
||||||
end
|
end
|
||||||
|
|
||||||
|
|||||||
@ -35,6 +35,7 @@ local FLOW_STABILITY_DELAY_MS = const.FLOW_STABILITY_DELAY_MS
|
|||||||
|
|
||||||
local ANNUNC_LIMS = const.ANNUNCIATOR_LIMITS
|
local ANNUNC_LIMS = const.ANNUNCIATOR_LIMITS
|
||||||
local ALARM_LIMS = const.ALARM_LIMITS
|
local ALARM_LIMS = const.ALARM_LIMITS
|
||||||
|
local RS_THRESH = const.RS_THRESHOLDS
|
||||||
|
|
||||||
---@class unit_logic_extension
|
---@class unit_logic_extension
|
||||||
local logic = {}
|
local logic = {}
|
||||||
@ -54,6 +55,10 @@ function logic.update_annunciator(self)
|
|||||||
-- variables for boiler, or reactor if no boilers used
|
-- variables for boiler, or reactor if no boilers used
|
||||||
local total_boil_rate = 0.0
|
local total_boil_rate = 0.0
|
||||||
|
|
||||||
|
-- auxiliary coolant control
|
||||||
|
local need_aux_cool = false
|
||||||
|
local dis_aux_cool = true
|
||||||
|
|
||||||
--#region Reactor
|
--#region Reactor
|
||||||
|
|
||||||
annunc.AutoControl = self.auto_engaged
|
annunc.AutoControl = self.auto_engaged
|
||||||
@ -148,6 +153,9 @@ function logic.update_annunciator(self)
|
|||||||
-- if no boilers, use reactor heating rate to check for boil rate mismatch
|
-- if no boilers, use reactor heating rate to check for boil rate mismatch
|
||||||
if num_boilers == 0 then
|
if num_boilers == 0 then
|
||||||
total_boil_rate = plc_db.mek_status.heating_rate
|
total_boil_rate = plc_db.mek_status.heating_rate
|
||||||
|
|
||||||
|
need_aux_cool = plc_db.mek_status.ccool_fill <= RS_THRESH.AUX_COOL_ENABLE
|
||||||
|
dis_aux_cool = plc_db.mek_status.ccool_fill >= RS_THRESH.AUX_COOL_DISABLE
|
||||||
end
|
end
|
||||||
else
|
else
|
||||||
self.plc_cache.ok = false
|
self.plc_cache.ok = false
|
||||||
@ -215,6 +223,9 @@ function logic.update_annunciator(self)
|
|||||||
|
|
||||||
annunc.BoilerOnline[idx] = true
|
annunc.BoilerOnline[idx] = true
|
||||||
annunc.WaterLevelLow[idx] = boiler.tanks.water_fill < ANNUNC_LIMS.WaterLevelLow
|
annunc.WaterLevelLow[idx] = boiler.tanks.water_fill < ANNUNC_LIMS.WaterLevelLow
|
||||||
|
|
||||||
|
need_aux_cool = need_aux_cool or (boiler.tanks.water_fill <= RS_THRESH.AUX_COOL_ENABLE)
|
||||||
|
dis_aux_cool = dis_aux_cool and (boiler.tanks.water_fill >= RS_THRESH.AUX_COOL_DISABLE)
|
||||||
end
|
end
|
||||||
|
|
||||||
-- check heating rate low
|
-- check heating rate low
|
||||||
@ -341,11 +352,11 @@ function logic.update_annunciator(self)
|
|||||||
end
|
end
|
||||||
|
|
||||||
if rotation_stable then
|
if rotation_stable then
|
||||||
log.debug(util.c("UNIT ", self.r_id, ": turbine ", idx, " reached rotational stability (", rotation, ")"))
|
log.debug(util.c("UNIT ", self.r_id, " turbine ", idx, " reached rotational stability (", rotation, ")"))
|
||||||
end
|
end
|
||||||
|
|
||||||
if flow_stable then
|
if flow_stable then
|
||||||
log.debug(util.c("UNIT ", self.r_id, ": turbine ", idx, " reached flow stability (", turbine.state.flow_rate, " mB/t)"))
|
log.debug(util.c("UNIT ", self.r_id, " turbine ", idx, " reached flow stability (", turbine.state.flow_rate, " mB/t)"))
|
||||||
end
|
end
|
||||||
|
|
||||||
turbines_stable = turbines_stable and (rotation_stable or flow_stable)
|
turbines_stable = turbines_stable and (rotation_stable or flow_stable)
|
||||||
@ -357,7 +368,7 @@ function logic.update_annunciator(self)
|
|||||||
|
|
||||||
turbines_stable = false
|
turbines_stable = false
|
||||||
|
|
||||||
log.debug(util.c("UNIT ", self.r_id, ": turbine ", idx, " reset stability (new rate ", turbine.state.steam_input_rate, " != ", last.input_rate," mB/t)"))
|
log.debug(util.c("UNIT ", self.r_id, " turbine ", idx, " reset stability (new rate ", turbine.state.steam_input_rate, " != ", last.input_rate," mB/t)"))
|
||||||
end
|
end
|
||||||
|
|
||||||
last.input_rate = turbine.state.steam_input_rate
|
last.input_rate = turbine.state.steam_input_rate
|
||||||
@ -406,6 +417,12 @@ function logic.update_annunciator(self)
|
|||||||
|
|
||||||
-- update auto control ready state for this unit
|
-- update auto control ready state for this unit
|
||||||
self.db.control.ready = plc_ready and boilers_ready and turbines_ready
|
self.db.control.ready = plc_ready and boilers_ready and turbines_ready
|
||||||
|
|
||||||
|
-- update auxiliary coolant command
|
||||||
|
if plc_ready then
|
||||||
|
self.enable_aux_cool = self.plc_i.get_db().mek_status.status and
|
||||||
|
(self.enable_aux_cool or need_aux_cool) and not (dis_aux_cool and self.turbine_flow_stable)
|
||||||
|
else self.enable_aux_cool = false end
|
||||||
end
|
end
|
||||||
|
|
||||||
-- update an alarm state given conditions
|
-- update an alarm state given conditions
|
||||||
@ -728,7 +745,7 @@ function logic.update_status_text(self)
|
|||||||
self.status_text = { "RCS TRANSIENT", "check coolant system" }
|
self.status_text = { "RCS TRANSIENT", "check coolant system" }
|
||||||
-- elseif is_active(self.alarms.RPSTransient) then
|
-- elseif is_active(self.alarms.RPSTransient) then
|
||||||
-- RPS status handled when checking reactor status
|
-- RPS status handled when checking reactor status
|
||||||
elseif self.emcool_opened then
|
elseif self.em_cool_opened then
|
||||||
self.status_text = { "EMERGENCY COOLANT OPENED", "reset RPS to close valve" }
|
self.status_text = { "EMERGENCY COOLANT OPENED", "reset RPS to close valve" }
|
||||||
-- connection dependent states
|
-- connection dependent states
|
||||||
elseif self.plc_i ~= nil then
|
elseif self.plc_i ~= nil then
|
||||||
@ -886,7 +903,7 @@ function logic.handle_redstone(self)
|
|||||||
(annunc.CoolantLevelLow or (boiler_water_low and rps.ex_hcool)) and
|
(annunc.CoolantLevelLow or (boiler_water_low and rps.ex_hcool)) and
|
||||||
is_active(self.alarms.ReactorOverTemp))
|
is_active(self.alarms.ReactorOverTemp))
|
||||||
|
|
||||||
if enable_emer_cool and not self.emcool_opened then
|
if enable_emer_cool and not self.em_cool_opened then
|
||||||
log.debug(util.c(">> Emergency Coolant Enable Detail Report (Unit ", self.r_id, ") <<"))
|
log.debug(util.c(">> Emergency Coolant Enable Detail Report (Unit ", self.r_id, ") <<"))
|
||||||
log.debug(util.c("| CoolantLevelLow[", annunc.CoolantLevelLow, "] CoolantLevelLowLow[", rps.low_cool, "] ExcessHeatedCoolant[", rps.ex_hcool, "]"))
|
log.debug(util.c("| CoolantLevelLow[", annunc.CoolantLevelLow, "] CoolantLevelLowLow[", rps.low_cool, "] ExcessHeatedCoolant[", rps.ex_hcool, "]"))
|
||||||
log.debug(util.c("| ReactorOverTemp[", AISTATE_NAMES[self.alarms.ReactorOverTemp.state], "]"))
|
log.debug(util.c("| ReactorOverTemp[", AISTATE_NAMES[self.alarms.ReactorOverTemp.state], "]"))
|
||||||
@ -910,13 +927,13 @@ function logic.handle_redstone(self)
|
|||||||
end
|
end
|
||||||
end
|
end
|
||||||
|
|
||||||
if annunc.EmergencyCoolant > 1 and self.emcool_opened then
|
if annunc.EmergencyCoolant > 1 and self.em_cool_opened then
|
||||||
log.info(util.c("UNIT ", self.r_id, " emergency coolant valve closed"))
|
log.info(util.c("UNIT ", self.r_id, " emergency coolant valve closed"))
|
||||||
log.info(util.c("UNIT ", self.r_id, " turbines set to not dump steam"))
|
log.info(util.c("UNIT ", self.r_id, " turbines set to not dump steam"))
|
||||||
end
|
end
|
||||||
|
|
||||||
self.emcool_opened = false
|
self.em_cool_opened = false
|
||||||
elseif enable_emer_cool or self.emcool_opened then
|
elseif enable_emer_cool or self.em_cool_opened then
|
||||||
-- set turbines to dump excess steam
|
-- set turbines to dump excess steam
|
||||||
for i = 1, #self.turbines do
|
for i = 1, #self.turbines do
|
||||||
local session = self.turbines[i]
|
local session = self.turbines[i]
|
||||||
@ -937,16 +954,33 @@ function logic.handle_redstone(self)
|
|||||||
end
|
end
|
||||||
end
|
end
|
||||||
|
|
||||||
if annunc.EmergencyCoolant > 1 and not self.emcool_opened then
|
if annunc.EmergencyCoolant > 1 and not self.em_cool_opened then
|
||||||
log.info(util.c("UNIT ", self.r_id, " emergency coolant valve opened"))
|
log.info(util.c("UNIT ", self.r_id, " emergency coolant valve opened"))
|
||||||
log.info(util.c("UNIT ", self.r_id, " turbines set to dump excess steam"))
|
log.info(util.c("UNIT ", self.r_id, " turbines set to dump excess steam"))
|
||||||
end
|
end
|
||||||
|
|
||||||
self.emcool_opened = true
|
self.em_cool_opened = true
|
||||||
end
|
end
|
||||||
|
|
||||||
-- set valve state always
|
-- set valve state always
|
||||||
if self.emcool_opened then self.valves.emer_cool.open() else self.valves.emer_cool.close() end
|
if self.em_cool_opened then self.valves.emer_cool.open() else self.valves.emer_cool.close() end
|
||||||
|
|
||||||
|
-----------------------
|
||||||
|
-- Auxiliary Coolant --
|
||||||
|
-----------------------
|
||||||
|
|
||||||
|
if self.aux_coolant then
|
||||||
|
if self.enable_aux_cool and (not self.aux_cool_opened) then
|
||||||
|
log.info(util.c("UNIT ", self.r_id, " auxiliary coolant valve opened"))
|
||||||
|
self.aux_cool_opened = true
|
||||||
|
elseif (not self.enable_aux_cool) and self.aux_cool_opened then
|
||||||
|
log.info(util.c("UNIT ", self.r_id, " auxiliary coolant valve closed"))
|
||||||
|
self.aux_cool_opened = false
|
||||||
|
end
|
||||||
|
|
||||||
|
-- set valve state always
|
||||||
|
if self.aux_cool_opened then self.valves.aux_cool.open() else self.valves.aux_cool.close() end
|
||||||
|
end
|
||||||
end
|
end
|
||||||
|
|
||||||
return logic
|
return logic
|
||||||
|
|||||||