reworked computed status logic and handle dynamic tank data

This commit is contained in:
Mikayla 2024-12-10 04:31:53 +00:00
parent 49b545ba2c
commit 20bffec79f
4 changed files with 133 additions and 129 deletions

View File

@ -20,6 +20,13 @@ local ENERGY_UNITS = types.ENERGY_SCALE_UNITS
local TEMP_SCALE = types.TEMP_SCALE local TEMP_SCALE = types.TEMP_SCALE
local TEMP_UNITS = types.TEMP_SCALE_UNITS local TEMP_UNITS = types.TEMP_SCALE_UNITS
local RCT_STATE = types.REACTOR_STATE
local BLR_STATE = types.BOILER_STATE
local TRB_STATE = types.TURBINE_STATE
local TNK_STATE = types.TANK_STATE
local MTX_STATE = types.IMATRIX_STATE
local SPS_STATE = types.SPS_STATE
-- nominal RTT is ping (0ms to 10ms usually) + 500ms for CRD main loop tick -- nominal RTT is ping (0ms to 10ms usually) + 500ms for CRD main loop tick
local WARN_RTT = 1000 -- 2x as long as expected w/ 0 ping local WARN_RTT = 1000 -- 2x as long as expected w/ 0 ping
local HIGH_RTT = 1500 -- 3.33x as long as expected w/ 0 ping local HIGH_RTT = 1500 -- 3.33x as long as expected w/ 0 ping
@ -119,7 +126,6 @@ function iocontrol.init(conf, comms, temp_scale, energy_scale)
induction_ps_tbl = {}, ---@type psil[] induction_ps_tbl = {}, ---@type psil[]
induction_data_tbl = {}, ---@type imatrix_session_db[] induction_data_tbl = {}, ---@type imatrix_session_db[]
sps_status = 1,
sps_ps_tbl = {}, ---@type psil[] sps_ps_tbl = {}, ---@type psil[]
sps_data_tbl = {}, ---@type sps_session_db[] sps_data_tbl = {}, ---@type sps_session_db[]
@ -151,10 +157,6 @@ function iocontrol.init(conf, comms, temp_scale, energy_scale)
local entry = { local entry = {
unit_id = i, unit_id = i,
connected = false, connected = false,
rtu_hw = {
boilers = {}, ---@type { connected: boolean, faulted: boolean }[]
turbines = {} ---@type { connected: boolean, faulted: boolean }[]
},
num_boilers = 0, num_boilers = 0,
num_turbines = 0, num_turbines = 0,
@ -249,14 +251,12 @@ function iocontrol.init(conf, comms, temp_scale, energy_scale)
for _ = 1, conf.cooling.r_cool[i].BoilerCount do for _ = 1, conf.cooling.r_cool[i].BoilerCount do
table.insert(entry.boiler_ps_tbl, psil.create()) table.insert(entry.boiler_ps_tbl, psil.create())
table.insert(entry.boiler_data_tbl, {}) table.insert(entry.boiler_data_tbl, {})
table.insert(entry.rtu_hw.boilers, { connected = false, faulted = false })
end end
-- create turbine tables -- create turbine tables
for _ = 1, conf.cooling.r_cool[i].TurbineCount do for _ = 1, conf.cooling.r_cool[i].TurbineCount do
table.insert(entry.turbine_ps_tbl, psil.create()) table.insert(entry.turbine_ps_tbl, psil.create())
table.insert(entry.turbine_data_tbl, {}) table.insert(entry.turbine_data_tbl, {})
table.insert(entry.rtu_hw.turbines, { connected = false, faulted = false })
end end
-- create tank tables -- create tank tables
@ -629,10 +629,12 @@ function iocontrol.update_facility_status(status)
-- induction matricies statuses -- induction matricies statuses
if type(rtu_statuses.induction) == "table" then if type(rtu_statuses.induction) == "table" then
local matrix_status = MTX_STATE.OFFLINE
for id = 1, #fac.induction_ps_tbl do for id = 1, #fac.induction_ps_tbl do
if rtu_statuses.induction[id] == nil then if rtu_statuses.induction[id] == nil then
-- disconnected -- disconnected
fac.induction_ps_tbl[id].publish("computed_status", 1) fac.induction_ps_tbl[id].publish("computed_status", matrix_status)
end end
end end
@ -644,18 +646,20 @@ function iocontrol.update_facility_status(status)
local rtu_faulted = _record_multiblock_status(matrix, data, ps) local rtu_faulted = _record_multiblock_status(matrix, data, ps)
if rtu_faulted then if rtu_faulted then
ps.publish("computed_status", 3) -- faulted matrix_status = MTX_STATE.FAULT
elseif data.formed then elseif data.formed then
if data.tanks.energy_fill >= 0.99 then if data.tanks.energy_fill >= 0.99 then
ps.publish("computed_status", 6) -- full matrix_status = MTX_STATE.HIGH_CHARGE
elseif data.tanks.energy_fill <= 0.01 then elseif data.tanks.energy_fill <= 0.01 then
ps.publish("computed_status", 5) -- empty matrix_status = MTX_STATE.LOW_CHARGE
else else
ps.publish("computed_status", 4) -- on-line matrix_status = MTX_STATE.ONLINE
end end
else else
ps.publish("computed_status", 2) -- not formed matrix_status = MTX_STATE.UNFORMED
end end
ps.publish("computed_status", matrix_status)
else else
log.debug(util.c(log_header, "invalid induction matrix id ", id)) log.debug(util.c(log_header, "invalid induction matrix id ", id))
end end
@ -667,12 +671,12 @@ function iocontrol.update_facility_status(status)
-- SPS statuses -- SPS statuses
if type(rtu_statuses.sps) == "table" then if type(rtu_statuses.sps) == "table" then
local sps_status = 1 local sps_status = SPS_STATE.OFFLINE
for id = 1, #fac.sps_ps_tbl do for id = 1, #fac.sps_ps_tbl do
if rtu_statuses.sps[id] == nil then if rtu_statuses.sps[id] == nil then
-- disconnected -- disconnected
fac.sps_ps_tbl[id].publish("computed_status", 1) fac.sps_ps_tbl[id].publish("computed_status", sps_status)
end end
end end
@ -684,11 +688,11 @@ function iocontrol.update_facility_status(status)
local rtu_faulted = _record_multiblock_status(sps, data, ps) local rtu_faulted = _record_multiblock_status(sps, data, ps)
if rtu_faulted then if rtu_faulted then
sps_status = 3 -- faulted sps_status = SPS_STATE.FAULT
elseif data.formed then elseif data.formed then
-- active / idle -- active / idle
sps_status = util.trinary(data.state.process_rate > 0, 5, 4) sps_status = util.trinary(data.state.process_rate > 0, SPS_STATE.ACTIVE, SPS_STATE.IDLE)
else sps_status = 2 end -- not formed else sps_status = SPS_STATE.UNFORMED end
ps.publish("computed_status", sps_status) ps.publish("computed_status", sps_status)
@ -697,8 +701,6 @@ function iocontrol.update_facility_status(status)
log.debug(util.c(log_header, "invalid sps id ", id)) log.debug(util.c(log_header, "invalid sps id ", id))
end end
end end
io.facility.sps_status = sps_status
else else
log.debug(log_header .. "sps list not a table") log.debug(log_header .. "sps list not a table")
valid = false valid = false
@ -706,10 +708,12 @@ function iocontrol.update_facility_status(status)
-- dynamic tank statuses -- dynamic tank statuses
if type(rtu_statuses.tanks) == "table" then if type(rtu_statuses.tanks) == "table" then
local tank_status = TNK_STATE.OFFLINE
for id = 1, #fac.tank_ps_tbl do for id = 1, #fac.tank_ps_tbl do
if rtu_statuses.tanks[id] == nil then if rtu_statuses.tanks[id] == nil then
-- disconnected -- disconnected
fac.tank_ps_tbl[id].publish("computed_status", 1) fac.tank_ps_tbl[id].publish("computed_status", tank_status)
end end
end end
@ -721,18 +725,18 @@ function iocontrol.update_facility_status(status)
local rtu_faulted = _record_multiblock_status(tank, data, ps) local rtu_faulted = _record_multiblock_status(tank, data, ps)
if rtu_faulted then if rtu_faulted then
ps.publish("computed_status", 3) -- faulted tank_status = TNK_STATE.FAULT
elseif data.formed then elseif data.formed then
if data.tanks.fill >= 0.99 then if data.tanks.fill >= 0.99 then
ps.publish("computed_status", 6) -- full tank_status = TNK_STATE.HIGH_FILL
elseif data.tanks.fill < 0.20 then elseif data.tanks.fill < 0.20 then
ps.publish("computed_status", 5) -- low tank_status = TNK_STATE.LOW_FILL
else else
ps.publish("computed_status", 4) -- on-line tank_status = TNK_STATE.ONLINE
end end
else else tank_status = TNK_STATE.UNFORMED end
ps.publish("computed_status", 2) -- not formed
end ps.publish("computed_status", tank_status)
else else
log.debug(util.c(log_header, "invalid dynamic tank id ", id)) log.debug(util.c(log_header, "invalid dynamic tank id ", id))
end end
@ -832,9 +836,11 @@ function iocontrol.update_unit_statuses(statuses)
log.debug(log_header .. "reactor status not a table") log.debug(log_header .. "reactor status not a table")
end end
local computed_status = RCT_STATE.OFFLINE
if #reactor_status == 0 then if #reactor_status == 0 then
unit.connected = false unit.connected = false
unit.unit_ps.publish("computed_status", 1) -- disconnected unit.unit_ps.publish("computed_status", computed_status)
elseif #reactor_status == 3 then elseif #reactor_status == 3 then
local mek_status = reactor_status[1] local mek_status = reactor_status[1]
local rps_status = reactor_status[2] local rps_status = reactor_status[2]
@ -873,22 +879,23 @@ function iocontrol.update_unit_statuses(statuses)
burn_rate_sum = burn_rate_sum + burn_rate burn_rate_sum = burn_rate_sum + burn_rate
if unit.reactor_data.mek_status.status then if unit.reactor_data.mek_status.status then
unit.unit_ps.publish("computed_status", 5) -- running computed_status = RCT_STATE.ACTIVE
else else
if unit.reactor_data.no_reactor then if unit.reactor_data.no_reactor then
unit.unit_ps.publish("computed_status", 3) -- faulted computed_status = RCT_STATE.FAULT
elseif not unit.reactor_data.formed then elseif not unit.reactor_data.formed then
unit.unit_ps.publish("computed_status", 2) -- multiblock not formed computed_status = RCT_STATE.UNFORMED
elseif unit.reactor_data.rps_status.force_dis then elseif unit.reactor_data.rps_status.force_dis then
unit.unit_ps.publish("computed_status", 7) -- reactor force disabled computed_status = RCT_STATE.FORCE_DISABLED
elseif unit.reactor_data.rps_tripped and unit.reactor_data.rps_trip_cause ~= "manual" then elseif unit.reactor_data.rps_tripped and unit.reactor_data.rps_trip_cause ~= "manual" then
unit.unit_ps.publish("computed_status", 6) -- SCRAM computed_status = RCT_STATE.SCRAMMED
else else
unit.unit_ps.publish("computed_status", 4) -- disabled computed_status = RCT_STATE.DISABLED
end end
end end
unit.connected = true unit.connected = true
unit.unit_ps.publish("computed_status", computed_status)
else else
log.debug(log_header .. "reactor status length mismatch") log.debug(log_header .. "reactor status length mismatch")
valid = false valid = false
@ -902,13 +909,11 @@ function iocontrol.update_unit_statuses(statuses)
if type(rtu_statuses.boilers) == "table" then if type(rtu_statuses.boilers) == "table" then
local boil_sum = 0 local boil_sum = 0
for id = 1, #unit.boiler_ps_tbl do computed_status = BLR_STATE.OFFLINE
local connected = rtu_statuses.boilers[id] ~= nil
unit.rtu_hw.boilers[id].connected = connected
if not connected then for id = 1, #unit.boiler_ps_tbl do
-- disconnected if rtu_statuses.boilers[id] == nil then
unit.boiler_ps_tbl[id].publish("computed_status", 1) unit.boiler_ps_tbl[id].publish("computed_status", computed_status)
end end
end end
@ -918,21 +923,15 @@ function iocontrol.update_unit_statuses(statuses)
local ps = unit.boiler_ps_tbl[id] local ps = unit.boiler_ps_tbl[id]
local rtu_faulted = _record_multiblock_status(boiler, data, ps) local rtu_faulted = _record_multiblock_status(boiler, data, ps)
unit.rtu_hw.boilers[id].faulted = rtu_faulted
if rtu_faulted then if rtu_faulted then
ps.publish("computed_status", 3) -- faulted computed_status = BLR_STATE.FAULT
elseif data.formed then elseif data.formed then
boil_sum = boil_sum + data.state.boil_rate boil_sum = boil_sum + data.state.boil_rate
computed_status = util.trinary(data.state.boil_rate > 0, BLR_STATE.ACTIVE, BLR_STATE.IDLE)
else computed_status = BLR_STATE.UNFORMED end
if data.state.boil_rate > 0 then unit.boiler_ps_tbl[id].publish("computed_status", computed_status)
ps.publish("computed_status", 5) -- active
else
ps.publish("computed_status", 4) -- idle
end
else
ps.publish("computed_status", 2) -- not formed
end
else else
log.debug(util.c(log_header, "invalid boiler id ", id)) log.debug(util.c(log_header, "invalid boiler id ", id))
valid = false valid = false
@ -949,13 +948,11 @@ function iocontrol.update_unit_statuses(statuses)
if type(rtu_statuses.turbines) == "table" then if type(rtu_statuses.turbines) == "table" then
local flow_sum = 0 local flow_sum = 0
for id = 1, #unit.turbine_ps_tbl do computed_status = TRB_STATE.OFFLINE
local connected = rtu_statuses.turbines[id] ~= nil
unit.rtu_hw.turbines[id].connected = connected
if not connected then for id = 1, #unit.turbine_ps_tbl do
-- disconnected if rtu_statuses.turbines[id] == nil then
unit.turbine_ps_tbl[id].publish("computed_status", 1) unit.turbine_ps_tbl[id].publish("computed_status", computed_status)
end end
end end
@ -965,23 +962,22 @@ function iocontrol.update_unit_statuses(statuses)
local ps = unit.turbine_ps_tbl[id] local ps = unit.turbine_ps_tbl[id]
local rtu_faulted = _record_multiblock_status(turbine, data, ps) local rtu_faulted = _record_multiblock_status(turbine, data, ps)
unit.rtu_hw.turbines[id].faulted = rtu_faulted
if rtu_faulted then if rtu_faulted then
ps.publish("computed_status", 3) -- faulted computed_status = TRB_STATE.FAULT
elseif data.formed then elseif data.formed then
flow_sum = flow_sum + data.state.flow_rate flow_sum = flow_sum + data.state.flow_rate
if data.tanks.energy_fill >= 0.99 then if data.tanks.energy_fill >= 0.99 then
ps.publish("computed_status", 6) -- trip computed_status = TRB_STATE.TRIPPED
elseif data.state.flow_rate < 100 then elseif data.state.flow_rate < 100 then
ps.publish("computed_status", 4) -- idle computed_status = TRB_STATE.IDLE
else else
ps.publish("computed_status", 5) -- active computed_status = TRB_STATE.ACTIVE
end end
else else computed_status = TRB_STATE.UNFORMED end
ps.publish("computed_status", 2) -- not formed
end unit.turbine_ps_tbl[id].publish("computed_status", computed_status)
else else
log.debug(util.c(log_header, "invalid turbine id ", id)) log.debug(util.c(log_header, "invalid turbine id ", id))
valid = false valid = false
@ -996,10 +992,11 @@ function iocontrol.update_unit_statuses(statuses)
-- dynamic tank statuses -- dynamic tank statuses
if type(rtu_statuses.tanks) == "table" then if type(rtu_statuses.tanks) == "table" then
computed_status = TNK_STATE.OFFLINE
for id = 1, #unit.tank_ps_tbl do for id = 1, #unit.tank_ps_tbl do
if rtu_statuses.tanks[id] == nil then if rtu_statuses.tanks[id] == nil then
-- disconnected unit.tank_ps_tbl[id].publish("computed_status", computed_status)
unit.tank_ps_tbl[id].publish("computed_status", 1)
end end
end end
@ -1011,18 +1008,18 @@ function iocontrol.update_unit_statuses(statuses)
local rtu_faulted = _record_multiblock_status(tank, data, ps) local rtu_faulted = _record_multiblock_status(tank, data, ps)
if rtu_faulted then if rtu_faulted then
ps.publish("computed_status", 3) -- faulted computed_status = TNK_STATE.FAULT
elseif data.formed then elseif data.formed then
if data.tanks.fill >= 0.99 then if data.tanks.fill >= 0.99 then
ps.publish("computed_status", 6) -- full computed_status = TNK_STATE.HIGH_FILL
elseif data.tanks.fill < 0.20 then elseif data.tanks.fill < 0.20 then
ps.publish("computed_status", 5) -- low computed_status = TNK_STATE.LOW_FILL
else else
ps.publish("computed_status", 4) -- on-line computed_status = TNK_STATE.ONLINE
end end
else else computed_status = TNK_STATE.UNFORMED end
ps.publish("computed_status", 2) -- not formed
end unit.tank_ps_tbl[id].publish("computed_status", computed_status)
else else
log.debug(util.c(log_header, "invalid dynamic tank id ", id)) log.debug(util.c(log_header, "invalid dynamic tank id ", id))
valid = false valid = false

View File

@ -269,11 +269,17 @@ function pocket.new_session(id, s_addr, i_seq_num, in_queue, out_queue, timeout)
if pkt.length == 1 and type(pkt.data[1]) == "number" then if pkt.length == 1 and type(pkt.data[1]) == "number" then
local u = db.units[pkt.data[1]] local u = db.units[pkt.data[1]]
local statuses = { u.unit_ps.get("computed_status") }
for i = 1, #u.boiler_ps_tbl do table.insert(statuses, u.boiler_ps_tbl[i].get("computed_status")) end
for i = 1, #u.turbine_ps_tbl do table.insert(statuses, u.turbine_ps_tbl[i].get("computed_status")) end
for i = 1, #u.tank_ps_tbl do table.insert(statuses, u.tank_ps_tbl[i].get("computed_status")) end
if u then if u then
local data = { local data = {
u.unit_id, u.unit_id,
u.connected, u.connected,
u.rtu_hw, statuses,
u.a_group, u.a_group,
u.alarms, u.alarms,
u.annunciator, u.annunciator,
@ -375,7 +381,7 @@ function pocket.new_session(id, s_addr, i_seq_num, in_queue, out_queue, timeout)
proc.pu_fallback, proc.pu_fallback,
proc.sps_low_power, proc.sps_low_power,
fac.waste_stats, fac.waste_stats,
fac.sps_status, fac.sps_ps_tbl[1].get("computed_status") or types.SPS_STATE.OFFLINE,
process_rate process_rate
} }

View File

@ -196,8 +196,6 @@ function iocontrol.init_fac(conf)
local entry = { local entry = {
unit_id = i, unit_id = i,
connected = false, connected = false,
---@type { boilers: { connected: boolean, faulted: boolean }[], turbines: { connected: boolean, faulted: boolean }[] }
rtu_hw = {},
num_boilers = 0, num_boilers = 0,
num_turbines = 0, num_turbines = 0,

View File

@ -9,6 +9,10 @@ local util = require("scada-common.util")
local ALARM = types.ALARM local ALARM = types.ALARM
local ALARM_STATE = types.ALARM_STATE local ALARM_STATE = types.ALARM_STATE
local BLR_STATE = types.BOILER_STATE
local TRB_STATE = types.TURBINE_STATE
local TNK_STATE = types.TANK_STATE
local io ---@type pocket_ioctl local io ---@type pocket_ioctl
local iorx = {} ---@class iorx local iorx = {} ---@class iorx
@ -61,10 +65,12 @@ function iorx.record_unit_data(data)
local unit = io.units[data[1]] local unit = io.units[data[1]]
unit.connected = data[2] unit.connected = data[2]
unit.rtu_hw = data[3] local comp_statuses = data[3]
unit.a_group = data[4] unit.a_group = data[4]
unit.alarms = data[5] unit.alarms = data[5]
local next_c_stat = 1
unit.unit_ps.publish("auto_group_id", unit.a_group) unit.unit_ps.publish("auto_group_id", unit.a_group)
unit.unit_ps.publish("auto_group", types.AUTO_GROUP_NAMES[unit.a_group + 1]) unit.unit_ps.publish("auto_group", types.AUTO_GROUP_NAMES[unit.a_group + 1])
@ -152,43 +158,27 @@ function iorx.record_unit_data(data)
local control_status = 1 local control_status = 1
local reactor_status = 1 local reactor_status = 1
local reactor_state = 1
local rps_status = 1 local rps_status = 1
if unit.connected then if unit.connected then
-- update RPS status -- update RPS status
if unit.reactor_data.rps_tripped then if unit.reactor_data.rps_tripped then
control_status = 2 control_status = 2
rps_status = util.trinary(unit.reactor_data.rps_trip_cause == "manual", 3, 2)
if unit.reactor_data.rps_trip_cause == "manual" then
reactor_state = 4 -- disabled
rps_status = 3
else
reactor_state = 6 -- SCRAM
rps_status = 2
end
else else
rps_status = 4 rps_status = 4
reactor_state = 4
end end
reactor_status = 4 -- ok, until proven otherwise
-- update reactor/control status -- update reactor/control status
if unit.reactor_data.mek_status.status then if unit.reactor_data.mek_status.status then
reactor_status = 4
reactor_state = 5 -- running
control_status = util.trinary(unit.annunciator.AutoControl, 4, 3) control_status = util.trinary(unit.annunciator.AutoControl, 4, 3)
else else
if unit.reactor_data.no_reactor then if unit.reactor_data.no_reactor then
reactor_status = 2 reactor_status = 2
reactor_state = 3 -- faulted elseif (not unit.reactor_data.formed) or unit.reactor_data.rps_status.force_dis then
elseif not unit.reactor_data.formed then
reactor_status = 3 reactor_status = 3
reactor_state = 2 -- not formed
elseif unit.reactor_data.rps_status.force_dis then
reactor_status = 3
reactor_state = 7 -- force disabled
else
reactor_status = 4
end end
end end
@ -213,9 +203,11 @@ function iorx.record_unit_data(data)
unit.unit_ps.publish("U_ControlStatus", control_status) unit.unit_ps.publish("U_ControlStatus", control_status)
unit.unit_ps.publish("U_ReactorStatus", reactor_status) unit.unit_ps.publish("U_ReactorStatus", reactor_status)
unit.unit_ps.publish("U_ReactorStateStatus", reactor_state) unit.unit_ps.publish("U_ReactorStateStatus", comp_statuses[next_c_stat])
unit.unit_ps.publish("U_RPS", rps_status) unit.unit_ps.publish("U_RPS", rps_status)
next_c_stat = next_c_stat + 1
--#endregion --#endregion
--#region RTU Devices --#region RTU Devices
@ -225,32 +217,26 @@ function iorx.record_unit_data(data)
for id = 1, #unit.boiler_data_tbl do for id = 1, #unit.boiler_data_tbl do
local boiler = unit.boiler_data_tbl[id] local boiler = unit.boiler_data_tbl[id]
local ps = unit.boiler_ps_tbl[id] local ps = unit.boiler_ps_tbl[id]
local c_stat = comp_statuses[next_c_stat]
local boiler_status = 1 local boiler_status = 1
local computed_status = 1
if unit.rtu_hw.boilers[id].connected then if c_stat ~= BLR_STATE.OFFLINE then
if unit.rtu_hw.boilers[id].faulted then if c_stat == BLR_STATE.FAULT then
boiler_status = 3 boiler_status = 3
computed_status = 3 elseif c_stat ~= BLR_STATE.UNFORMED then
elseif boiler.formed then
boiler_status = 4 boiler_status = 4
if boiler.state.boil_rate > 0 then
computed_status = 5
else
computed_status = 4
end
else else
boiler_status = 2 boiler_status = 2
computed_status = 2
end end
_record_multiblock_status(unit.rtu_hw.boilers[id].faulted, boiler, ps) _record_multiblock_status(c_stat == BLR_STATE.FAULT, boiler, ps)
end end
ps.publish("BoilerStatus", boiler_status) ps.publish("BoilerStatus", boiler_status)
ps.publish("BoilerStateStatus", computed_status) ps.publish("BoilerStateStatus", c_stat)
next_c_stat = next_c_stat + 1
end end
unit.turbine_data_tbl = data[9] unit.turbine_data_tbl = data[9]
@ -258,38 +244,55 @@ function iorx.record_unit_data(data)
for id = 1, #unit.turbine_data_tbl do for id = 1, #unit.turbine_data_tbl do
local turbine = unit.turbine_data_tbl[id] local turbine = unit.turbine_data_tbl[id]
local ps = unit.turbine_ps_tbl[id] local ps = unit.turbine_ps_tbl[id]
local c_stat = comp_statuses[next_c_stat]
local turbine_status = 1 local turbine_status = 1
local computed_status = 1
if unit.rtu_hw.turbines[id].connected then if c_stat ~= TRB_STATE.OFFLINE then
if unit.rtu_hw.turbines[id].faulted then if c_stat == TRB_STATE.FAULT then
turbine_status = 3 turbine_status = 3
computed_status = 3
elseif turbine.formed then elseif turbine.formed then
turbine_status = 4 turbine_status = 4
if turbine.tanks.energy_fill >= 0.99 then
computed_status = 6
elseif turbine.state.flow_rate < 100 then
computed_status = 4
else
computed_status = 5
end
else else
turbine_status = 2 turbine_status = 2
computed_status = 2
end end
_record_multiblock_status(unit.rtu_hw.turbines[id].faulted, turbine, ps) _record_multiblock_status(c_stat == TRB_STATE.FAULT, turbine, ps)
end end
ps.publish("TurbineStatus", turbine_status) ps.publish("TurbineStatus", turbine_status)
ps.publish("TurbineStateStatus", computed_status) ps.publish("TurbineStateStatus", c_stat)
next_c_stat = next_c_stat + 1
end end
unit.tank_data_tbl = data[10] unit.tank_data_tbl = data[10]
for id = 1, #unit.tank_data_tbl do
local tank = unit.tank_data_tbl[id]
local ps = unit.tank_ps_tbl[id]
local c_stat = comp_statuses[next_c_stat]
local tank_status = 1
if c_stat ~= TNK_STATE.OFFLINE then
if c_stat == TNK_STATE.FAULT then
tank_status = 3
elseif tank.formed then
tank_status = 4
else
tank_status = 2
end
_record_multiblock_status(c_stat == TNK_STATE.FAULT, tank, ps)
end
ps.publish("DynamicTankStatus", tank_status)
ps.publish("DynamicTankStateStatus", c_stat)
next_c_stat = next_c_stat + 1
end
unit.last_rate_change_ms = data[11] unit.last_rate_change_ms = data[11]
unit.turbine_flow_stable = data[12] unit.turbine_flow_stable = data[12]