#480 updated aux coolant logic
This commit is contained in:
parent
d45f19c8a6
commit
2b73196130
@ -72,6 +72,8 @@ local rs = {}
|
||||
|
||||
rs.IMATRIX_CHARGE_LOW = 0.05 -- activation threshold (less than) for F_MATRIX_LOW
|
||||
rs.IMATRIX_CHARGE_HIGH = 0.95 -- activation threshold (greater than) for F_MATRIX_HIGH
|
||||
rs.AUX_COOL_ENABLE = 0.60 -- actiation threshold (less than or equal) for U_AUX_COOL
|
||||
rs.AUX_COOL_DISABLE = 1.00 -- deactivation threshold (greater than or equal) for U_AUX_COOL
|
||||
|
||||
constants.RS_THRESHOLDS = rs
|
||||
|
||||
|
||||
@ -114,6 +114,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle, aux_coolant)
|
||||
damage_est_last = 0,
|
||||
waste_product = WASTE.PLUTONIUM, ---@type WASTE_PRODUCT
|
||||
status_text = { "UNKNOWN", "awaiting connection..." },
|
||||
enable_aux_cool = false,
|
||||
-- logic for alarms
|
||||
had_reactor = false,
|
||||
turbine_flow_stable = false,
|
||||
|
||||
@ -35,6 +35,7 @@ local FLOW_STABILITY_DELAY_MS = const.FLOW_STABILITY_DELAY_MS
|
||||
|
||||
local ANNUNC_LIMS = const.ANNUNCIATOR_LIMITS
|
||||
local ALARM_LIMS = const.ALARM_LIMITS
|
||||
local RS_THRESH = const.RS_THRESHOLDS
|
||||
|
||||
---@class unit_logic_extension
|
||||
local logic = {}
|
||||
@ -54,6 +55,10 @@ function logic.update_annunciator(self)
|
||||
-- variables for boiler, or reactor if no boilers used
|
||||
local total_boil_rate = 0.0
|
||||
|
||||
-- auxiliary coolant control
|
||||
local need_aux_cool = false
|
||||
local dis_aux_cool = true
|
||||
|
||||
--#region Reactor
|
||||
|
||||
annunc.AutoControl = self.auto_engaged
|
||||
@ -148,6 +153,9 @@ function logic.update_annunciator(self)
|
||||
-- if no boilers, use reactor heating rate to check for boil rate mismatch
|
||||
if num_boilers == 0 then
|
||||
total_boil_rate = plc_db.mek_status.heating_rate
|
||||
|
||||
need_aux_cool = plc_db.mek_status.ccool_fill <= RS_THRESH.AUX_COOL_ENABLE
|
||||
dis_aux_cool = plc_db.mek_status.ccool_fill >= RS_THRESH.AUX_COOL_DISABLE
|
||||
end
|
||||
else
|
||||
self.plc_cache.ok = false
|
||||
@ -215,6 +223,9 @@ function logic.update_annunciator(self)
|
||||
|
||||
annunc.BoilerOnline[idx] = true
|
||||
annunc.WaterLevelLow[idx] = boiler.tanks.water_fill < ANNUNC_LIMS.WaterLevelLow
|
||||
|
||||
need_aux_cool = need_aux_cool or (boiler.tanks.water_fill <= RS_THRESH.AUX_COOL_ENABLE)
|
||||
dis_aux_cool = dis_aux_cool and (boiler.tanks.water_fill >= RS_THRESH.AUX_COOL_DISABLE)
|
||||
end
|
||||
|
||||
-- check heating rate low
|
||||
@ -406,6 +417,12 @@ function logic.update_annunciator(self)
|
||||
|
||||
-- update auto control ready state for this unit
|
||||
self.db.control.ready = plc_ready and boilers_ready and turbines_ready
|
||||
|
||||
-- update auxiliary coolant command
|
||||
if plc_ready then
|
||||
self.enable_aux_cool = self.plc_i.get_db().mek_status.status and
|
||||
(self.enable_aux_cool or need_aux_cool) and not (dis_aux_cool and self.turbine_flow_stable)
|
||||
else self.enable_aux_cool = false end
|
||||
end
|
||||
|
||||
-- update an alarm state given conditions
|
||||
@ -953,12 +970,10 @@ function logic.handle_redstone(self)
|
||||
-----------------------
|
||||
|
||||
if self.aux_coolant then
|
||||
local enable_aux_cool = boiler_water_low or (annunc.CoolantLevelLow and self.num_boilers == 0)
|
||||
|
||||
if enable_aux_cool and not self.aux_cool_opened then
|
||||
if self.enable_aux_cool and (not self.aux_cool_opened) then
|
||||
log.info(util.c("UNIT ", self.r_id, " auxiliary coolant valve opened"))
|
||||
self.aux_cool_opened = true
|
||||
elseif self.aux_cool_opened and self.turbine_flow_stable and not enable_aux_cool then
|
||||
elseif (not self.enable_aux_cool) and self.aux_cool_opened then
|
||||
log.info(util.c("UNIT ", self.r_id, " auxiliary coolant valve closed"))
|
||||
self.aux_cool_opened = false
|
||||
end
|
||||
|
||||
Loading…
x
Reference in New Issue
Block a user