additional supervisor config validations

This commit is contained in:
Mikayla Fischler 2025-02-25 14:52:05 -05:00
parent de41ee56aa
commit 7ab5ea710f
2 changed files with 17 additions and 0 deletions

View File

@ -299,6 +299,7 @@ function facility.create(tool_ctl, main_pane, cfg_sys, fac_cfg, style)
tmp_cfg.FacilityTankDefs = {} tmp_cfg.FacilityTankDefs = {}
tmp_cfg.FacilityTankList = {} tmp_cfg.FacilityTankList = {}
tmp_cfg.FacilityTankConns = {} tmp_cfg.FacilityTankConns = {}
tmp_cfg.TankFluidTypes = {}
end end
if any_has_tank then fac_pane.set_value(3) else main_pane.set_value(3) end if any_has_tank then fac_pane.set_value(3) else main_pane.set_value(3) end

View File

@ -10,6 +10,7 @@ local log = require("scada-common.log")
local network = require("scada-common.network") local network = require("scada-common.network")
local ppm = require("scada-common.ppm") local ppm = require("scada-common.ppm")
local tcd = require("scada-common.tcd") local tcd = require("scada-common.tcd")
local types = require("scada-common.types")
local util = require("scada-common.util") local util = require("scada-common.util")
local core = require("graphics.core") local core = require("graphics.core")
@ -72,6 +73,21 @@ if config.FacilityTankMode > 0 then
cfv.assert_type_int(def) cfv.assert_type_int(def)
cfv.assert_range(def, 0, 2) cfv.assert_range(def, 0, 2)
assert(cfv.valid(), "startup> invalid facility tank definition for reactor unit " .. i) assert(cfv.valid(), "startup> invalid facility tank definition for reactor unit " .. i)
local entry = config.FacilityTankList[i]
cfv.assert_type_int(entry)
cfv.assert_range(entry, 0, 2)
assert(cfv.valid(), "startup> invalid facility tank list entry for tank " .. i)
local conn = config.FacilityTankConns[i]
cfv.assert_type_int(conn)
cfv.assert_range(conn, 0, #config.FacilityTankDefs)
assert(cfv.valid(), "startup> invalid facility tank connection for reactor unit " .. i)
local type = config.TankFluidTypes[i]
cfv.assert_type_int(type)
cfv.assert_range(type, 0, types.COOLANT_TYPE.SODIUM)
assert(cfv.valid(), "startup> invalid tank fluid type for tank " .. i)
end end