Merge pull request #610 from MikaylaFischler/devel

2025.02.26 Release
This commit is contained in:
Mikayla 2025-02-26 18:52:56 -05:00 committed by GitHub
commit b1ad2084f2
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194
40 changed files with 705 additions and 244 deletions

View File

@ -550,7 +550,7 @@ function system.create(tool_ctl, main_pane, cfg_sys, divs, ext, style)
local c = util.trinary(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white)) local c = util.trinary(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white))
alternate = not alternate alternate = not alternate
if string.len(val) > val_max_w then if (string.len(val) > val_max_w) or string.find(val, "\n") then
local lines = util.strwrap(val, inner_width) local lines = util.strwrap(val, inner_width)
height = #lines + 1 height = #lines + 1
end end

View File

@ -380,6 +380,18 @@ function coordinator.comms(version, nic, sv_watchdog)
_send_sv(PROTOCOL.SCADA_MGMT, MGMT_TYPE.CLOSE, {}) _send_sv(PROTOCOL.SCADA_MGMT, MGMT_TYPE.CLOSE, {})
end end
-- send the resume ready state to the supervisor
---@param mode PROCESS process control mode
---@param burn_target number burn rate target
---@param charge_target number charge level target
---@param gen_target number generation rate target
---@param limits number[] unit burn rate limits
function public.send_ready(mode, burn_target, charge_target, gen_target, limits)
_send_sv(PROTOCOL.SCADA_CRDN, CRDN_TYPE.PROCESS_READY, {
mode, burn_target, charge_target, gen_target, limits
})
end
-- send a facility command -- send a facility command
---@param cmd FAC_COMMAND command ---@param cmd FAC_COMMAND command
---@param option any? optional option options for the optional options (like waste mode) ---@param option any? optional option options for the optional options (like waste mode)

View File

@ -164,6 +164,7 @@ function iocontrol.init(conf, comms, temp_scale, energy_scale)
num_turbines = 0, num_turbines = 0,
num_snas = 0, num_snas = 0,
has_tank = conf.cooling.r_cool[i].TankConnection, has_tank = conf.cooling.r_cool[i].TankConnection,
aux_coolant = conf.cooling.aux_coolant[i],
status_lines = { "", "" }, status_lines = { "", "" },
@ -1214,7 +1215,7 @@ function iocontrol.update_unit_statuses(statuses)
local valve_states = status[6] local valve_states = status[6]
if type(valve_states) == "table" then if type(valve_states) == "table" then
if #valve_states == 5 then if #valve_states == 6 then
unit.unit_ps.publish("V_pu_conn", valve_states[1] > 0) unit.unit_ps.publish("V_pu_conn", valve_states[1] > 0)
unit.unit_ps.publish("V_pu_state", valve_states[1] == 2) unit.unit_ps.publish("V_pu_state", valve_states[1] == 2)
unit.unit_ps.publish("V_po_conn", valve_states[2] > 0) unit.unit_ps.publish("V_po_conn", valve_states[2] > 0)
@ -1225,6 +1226,8 @@ function iocontrol.update_unit_statuses(statuses)
unit.unit_ps.publish("V_am_state", valve_states[4] == 2) unit.unit_ps.publish("V_am_state", valve_states[4] == 2)
unit.unit_ps.publish("V_emc_conn", valve_states[5] > 0) unit.unit_ps.publish("V_emc_conn", valve_states[5] > 0)
unit.unit_ps.publish("V_emc_state", valve_states[5] == 2) unit.unit_ps.publish("V_emc_state", valve_states[5] == 2)
unit.unit_ps.publish("V_aux_conn", valve_states[6] > 0)
unit.unit_ps.publish("V_aux_state", valve_states[6] == 2)
else else
log.debug(log_header .. "valve states length mismatch") log.debug(log_header .. "valve states length mismatch")
valid = false valid = false

View File

@ -139,6 +139,11 @@ function process.init(iocontrol, coord_comms)
log.info("PROCESS: loaded priority groups settings") log.info("PROCESS: loaded priority groups settings")
end end
-- report to the supervisor all initial configuration data has been sent
-- startup resume can occur if needed
local p = ctl_proc
pctl.comms.send_ready(p.mode, p.burn_target, p.charge_target, p.gen_target, p.limits)
end end
-- create a handle to process control for usage of commands that get acknowledgements -- create a handle to process control for usage of commands that get acknowledgements

View File

@ -137,7 +137,7 @@ function renderer.try_start_fp()
if not engine.fp_ready then if not engine.fp_ready then
-- show front panel view on terminal -- show front panel view on terminal
status, msg = pcall(function () status, msg = pcall(function ()
engine.ui.front_panel = DisplayBox{window=term.native(),fg_bg=style.fp.root} engine.ui.front_panel = DisplayBox{window=term.current(),fg_bg=style.fp.root}
panel_view(engine.ui.front_panel, #engine.monitors.unit_displays) panel_view(engine.ui.front_panel, #engine.monitors.unit_displays)
end) end)

View File

@ -19,7 +19,7 @@ local renderer = require("coordinator.renderer")
local sounder = require("coordinator.sounder") local sounder = require("coordinator.sounder")
local threads = require("coordinator.threads") local threads = require("coordinator.threads")
local COORDINATOR_VERSION = "v1.6.4" local COORDINATOR_VERSION = "v1.6.11"
local CHUNK_LOAD_DELAY_S = 30.0 local CHUNK_LOAD_DELAY_S = 30.0

View File

@ -28,6 +28,8 @@ local function init(parent, id)
local ps = iocontrol.get_db().fp.ps local ps = iocontrol.get_db().fp.ps
local term_w, _ = term.getSize()
-- root div -- root div
local root = Div{parent=parent,x=2,y=2,height=4,width=parent.get_width()-2} local root = Div{parent=parent,x=2,y=2,height=4,width=parent.get_width()-2}
local entry = Div{parent=root,x=2,y=1,height=3,fg_bg=s_hi_bright} local entry = Div{parent=root,x=2,y=1,height=3,fg_bg=s_hi_bright}
@ -43,9 +45,9 @@ local function init(parent, id)
local pkt_fw_v = TextBox{parent=entry,x=14,y=2,text=" ------- ",width=20,fg_bg=label_fg} local pkt_fw_v = TextBox{parent=entry,x=14,y=2,text=" ------- ",width=20,fg_bg=label_fg}
pkt_fw_v.register(ps, ps_prefix .. "fw", pkt_fw_v.set_value) pkt_fw_v.register(ps, ps_prefix .. "fw", pkt_fw_v.set_value)
TextBox{parent=entry,x=35,y=2,text="RTT:",width=4} TextBox{parent=entry,x=term_w-16,y=2,text="RTT:",width=4}
local pkt_rtt = DataIndicator{parent=entry,x=40,y=2,label="",unit="",format="%5d",value=0,width=5,fg_bg=label_fg} local pkt_rtt = DataIndicator{parent=entry,x=term_w-11,y=2,label="",unit="",format="%5d",value=0,width=5,fg_bg=label_fg}
TextBox{parent=entry,x=46,y=2,text="ms",width=4,fg_bg=label_fg} TextBox{parent=entry,x=term_w-5,y=2,text="ms",width=4,fg_bg=label_fg}
pkt_rtt.register(ps, ps_prefix .. "rtt", pkt_rtt.update) pkt_rtt.register(ps, ps_prefix .. "rtt", pkt_rtt.update)
pkt_rtt.register(ps, ps_prefix .. "rtt_color", pkt_rtt.recolor) pkt_rtt.register(ps, ps_prefix .. "rtt_color", pkt_rtt.recolor)

View File

@ -59,7 +59,7 @@ local function make(parent, x, y, wide, unit_id)
local tank_conns = facility.tank_conns local tank_conns = facility.tank_conns
local tank_types = facility.tank_fluid_types local tank_types = facility.tank_fluid_types
local v_start = 1 + ((unit.unit_id - 1) * 5) local v_start = 1 + ((unit.unit_id - 1) * 6)
local prv_start = 1 + ((unit.unit_id - 1) * 3) local prv_start = 1 + ((unit.unit_id - 1) * 3)
local v_fields = { "pu", "po", "pl", "am" } local v_fields = { "pu", "po", "pl", "am" }
local v_names = { local v_names = {
@ -96,9 +96,19 @@ local function make(parent, x, y, wide, unit_id)
table.insert(rc_pipes, pipe(0, 3, _wide(28, 19), 3, colors.orange, true)) table.insert(rc_pipes, pipe(0, 3, _wide(28, 19), 3, colors.orange, true))
table.insert(rc_pipes, pipe(_wide(46, 39), 1, _wide(72, 58), 1, colors.blue, true)) table.insert(rc_pipes, pipe(_wide(46, 39), 1, _wide(72, 58), 1, colors.blue, true))
table.insert(rc_pipes, pipe(_wide(46, 39), 3, _wide(72, 58), 3, colors.white, true)) table.insert(rc_pipes, pipe(_wide(46, 39), 3, _wide(72, 58), 3, colors.white, true))
if unit.aux_coolant then
local em_water = facility.tank_fluid_types[facility.tank_conns[unit_id]] == COOLANT_TYPE.WATER
local offset = util.trinary(unit.has_tank and em_water, 3, 0)
table.insert(rc_pipes, pipe(_wide(51, 41) + offset, 0, _wide(51, 41) + offset, 0, colors.blue, true))
end
else else
table.insert(rc_pipes, pipe(0, 1, _wide(72, 58), 1, colors.blue, true)) table.insert(rc_pipes, pipe(0, 1, _wide(72, 58), 1, colors.blue, true))
table.insert(rc_pipes, pipe(0, 3, _wide(72, 58), 3, colors.white, true)) table.insert(rc_pipes, pipe(0, 3, _wide(72, 58), 3, colors.white, true))
if unit.aux_coolant then
table.insert(rc_pipes, pipe(8, 0, 8, 0, colors.blue, true))
end
end end
if unit.has_tank then if unit.has_tank then
@ -222,17 +232,21 @@ local function make(parent, x, y, wide, unit_id)
_machine(_wide(116, 94), 6, "SPENT WASTE \x1b") _machine(_wide(116, 94), 6, "SPENT WASTE \x1b")
TextBox{parent=waste,x=_wide(30,25),y=3,text="SNAs [Po]",alignment=ALIGN.CENTER,width=19,fg_bg=wh_gray} TextBox{parent=waste,x=_wide(30,25),y=3,text="SNAs [Po]",alignment=ALIGN.CENTER,width=19,fg_bg=wh_gray}
local sna_po = Rectangle{parent=waste,x=_wide(30,25),y=4,border=border(1,colors.gray,true),width=19,height=7,thin=true,fg_bg=style.theme.highlight_box_bright} local sna_po = Rectangle{parent=waste,x=_wide(30,25),y=4,border=border(1,colors.gray,true),width=19,height=8,thin=true,fg_bg=style.theme.highlight_box_bright}
local sna_act = IndicatorLight{parent=sna_po,label="ACTIVE",colors=ind_grn} local sna_act = IndicatorLight{parent=sna_po,label="ACTIVE",colors=ind_grn}
local sna_cnt = DataIndicator{parent=sna_po,x=12,y=1,lu_colors=lu_c_d,label="CNT",unit="",format="%2d",value=0,width=7} local sna_cnt = DataIndicator{parent=sna_po,x=12,y=1,lu_colors=lu_c_d,label="CNT",unit="",format="%2d",value=0,width=7}
local sna_pk = DataIndicator{parent=sna_po,y=3,lu_colors=lu_c_d,label="PEAK",unit="mB/t",format="%7.2f",value=0,width=17} TextBox{parent=sna_po,y=3,text="PEAK\x1a",width=5,fg_bg=cpair(style.theme.label_dark,colors._INHERIT)}
local sna_max = DataIndicator{parent=sna_po,lu_colors=lu_c_d,label="MAX",unit="mB/t",format="%8.2f",value=0,width=17} TextBox{parent=sna_po,text="MAX \x1a",width=5,fg_bg=cpair(style.theme.label_dark,colors._INHERIT)}
local sna_in = DataIndicator{parent=sna_po,lu_colors=lu_c_d,label="IN",unit="mB/t",format="%9.2f",value=0,width=17} local sna_pk = DataIndicator{parent=sna_po,x=6,y=3,lu_colors=lu_c_d,label="",unit="mB/t",format="%7.2f",value=0,width=17}
local sna_max_o = DataIndicator{parent=sna_po,x=6,lu_colors=lu_c_d,label="",unit="mB/t",format="%7.2f",value=0,width=17}
local sna_max_i = DataIndicator{parent=sna_po,lu_colors=lu_c_d,label="\x1aMAX",unit="mB/t",format="%7.2f",value=0,width=17}
local sna_in = DataIndicator{parent=sna_po,lu_colors=lu_c_d,label="\x1aIN",unit="mB/t",format="%8.2f",value=0,width=17}
sna_act.register(unit.unit_ps, "po_rate", function (r) sna_act.update(r > 0) end) sna_act.register(unit.unit_ps, "po_rate", function (r) sna_act.update(r > 0) end)
sna_cnt.register(unit.unit_ps, "sna_count", sna_cnt.update) sna_cnt.register(unit.unit_ps, "sna_count", sna_cnt.update)
sna_pk.register(unit.unit_ps, "sna_peak_rate", sna_pk.update) sna_pk.register(unit.unit_ps, "sna_peak_rate", sna_pk.update)
sna_max.register(unit.unit_ps, "sna_max_rate", sna_max.update) sna_max_o.register(unit.unit_ps, "sna_max_rate", sna_max_o.update)
sna_max_i.register(unit.unit_ps, "sna_max_rate", function (r) sna_max_i.update(r * 10) end)
sna_in.register(unit.unit_ps, "sna_in", sna_in.update) sna_in.register(unit.unit_ps, "sna_in", sna_in.update)
return root return root

View File

@ -286,7 +286,7 @@ local function init(main)
TextBox{parent=main,x=12,y=vy,text="\x10\x11",fg_bg=text_col,width=2} TextBox{parent=main,x=12,y=vy,text="\x10\x11",fg_bg=text_col,width=2}
local conn = IndicatorLight{parent=main,x=9,y=vy+1,label=util.sprintf("PV%02d-EMC", i * 5),colors=style.ind_grn} local conn = IndicatorLight{parent=main,x=9,y=vy+1,label=util.sprintf("PV%02d-EMC", (i * 6) - 1),colors=style.ind_grn}
local open = IndicatorLight{parent=main,x=9,y=vy+2,label="OPEN",colors=style.ind_wht} local open = IndicatorLight{parent=main,x=9,y=vy+2,label="OPEN",colors=style.ind_wht}
conn.register(units[i].unit_ps, "V_emc_conn", conn.update) conn.register(units[i].unit_ps, "V_emc_conn", conn.update)
@ -294,6 +294,35 @@ local function init(main)
end end
end end
------------------------------
-- auxiliary coolant valves --
------------------------------
for i = 1, facility.num_units do
if units[i].aux_coolant then
local vx
local vy = 3 + y_ofs(i)
if #emcool_pipes == 0 then
vx = util.trinary(units[i].num_boilers == 0, 36, 79)
else
local em_water = tank_types[tank_conns[i]] == COOLANT_TYPE.WATER
vx = util.trinary(units[i].num_boilers == 0, 58, util.trinary(units[i].has_tank and em_water, 94, 91))
end
PipeNetwork{parent=main,x=vx-6,y=vy,pipes={pipe(0,1,9,0,colors.blue,true)},bg=style.theme.bg}
TextBox{parent=main,x=vx,y=vy,text="\x10\x11",fg_bg=text_col,width=2}
TextBox{parent=main,x=vx+5,y=vy,text="\x1b",fg_bg=cpair(colors.blue,text_col.bkg),width=1}
local conn = IndicatorLight{parent=main,x=vx-3,y=vy+1,label=util.sprintf("PV%02d-AUX", i * 6),colors=style.ind_grn}
local open = IndicatorLight{parent=main,x=vx-3,y=vy+2,label="OPEN",colors=style.ind_wht}
conn.register(units[i].unit_ps, "V_aux_conn", conn.update)
open.register(units[i].unit_ps, "V_aux_state", open.update)
end
end
------------------- -------------------
-- dynamic tanks -- -- dynamic tanks --
------------------- -------------------

View File

@ -39,6 +39,8 @@ local led_grn = style.led_grn
local function init(panel, num_units) local function init(panel, num_units)
local ps = iocontrol.get_db().fp.ps local ps = iocontrol.get_db().fp.ps
local term_w, term_h = term.getSize()
TextBox{parent=panel,y=1,text="SCADA COORDINATOR",alignment=ALIGN.CENTER,fg_bg=style.fp_theme.header} TextBox{parent=panel,y=1,text="SCADA COORDINATOR",alignment=ALIGN.CENTER,fg_bg=style.fp_theme.header}
local page_div = Div{parent=panel,x=1,y=3} local page_div = Div{parent=panel,x=1,y=3}
@ -61,7 +63,7 @@ local function init(panel, num_units)
local modem = LED{parent=system,label="MODEM",colors=led_grn} local modem = LED{parent=system,label="MODEM",colors=led_grn}
if not style.colorblind then if not style.colorblind then
local network = RGBLED{parent=system,label="NETWORK",colors={colors.green,colors.red,colors.orange,colors.yellow,style.fp_ind_bkg}} local network = RGBLED{parent=system,label="NETWORK",colors={colors.green,colors.red,colors.yellow,colors.orange,style.fp_ind_bkg}}
network.update(types.PANEL_LINK_STATE.DISCONNECTED) network.update(types.PANEL_LINK_STATE.DISCONNECTED)
network.register(ps, "link_state", network.update) network.register(ps, "link_state", network.update)
else else
@ -131,9 +133,9 @@ local function init(panel, num_units)
-- about footer -- about footer
-- --
local about = Div{parent=main_page,width=15,height=3,x=1,y=16,fg_bg=style.fp.disabled_fg} local about = Div{parent=main_page,width=15,height=2,y=term_h-3,fg_bg=style.fp.disabled_fg}
local fw_v = TextBox{parent=about,x=1,y=1,text="FW: v00.00.00"} local fw_v = TextBox{parent=about,text="FW: v00.00.00"}
local comms_v = TextBox{parent=about,x=1,y=2,text="NT: v00.00.00"} local comms_v = TextBox{parent=about,text="NT: v00.00.00"}
fw_v.register(ps, "version", function (version) fw_v.set_value(util.c("FW: ", version)) end) fw_v.register(ps, "version", function (version) fw_v.set_value(util.c("FW: ", version)) end)
comms_v.register(ps, "comms_version", function (version) comms_v.set_value(util.c("NT: v", version)) end) comms_v.register(ps, "comms_version", function (version) comms_v.set_value(util.c("NT: v", version)) end)
@ -145,7 +147,7 @@ local function init(panel, num_units)
-- API page -- API page
local api_page = Div{parent=page_div,x=1,y=1,hidden=true} local api_page = Div{parent=page_div,x=1,y=1,hidden=true}
local api_list = ListBox{parent=api_page,x=1,y=1,height=17,width=51,scroll_height=1000,fg_bg=style.fp.text_fg,nav_fg_bg=cpair(colors.gray,colors.lightGray),nav_active=cpair(colors.black,colors.gray)} local api_list = ListBox{parent=api_page,y=1,height=term_h-2,width=term_w,scroll_height=1000,fg_bg=style.fp.text_fg,nav_fg_bg=cpair(colors.gray,colors.lightGray),nav_active=cpair(colors.black,colors.gray)}
local _ = Div{parent=api_list,height=1} -- padding local _ = Div{parent=api_list,height=1} -- padding
-- assemble page panes -- assemble page panes

View File

@ -385,7 +385,7 @@ function system.create(tool_ctl, main_pane, cfg_sys, divs, style, exit)
local c = tri(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white)) local c = tri(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white))
alternate = not alternate alternate = not alternate
if string.len(val) > val_max_w then if (string.len(val) > val_max_w) or string.find(val, "\n") then
local lines = util.strwrap(val, inner_width) local lines = util.strwrap(val, inner_width)
height = #lines + 1 height = #lines + 1
end end

View File

@ -20,7 +20,7 @@ local pocket = require("pocket.pocket")
local renderer = require("pocket.renderer") local renderer = require("pocket.renderer")
local threads = require("pocket.threads") local threads = require("pocket.threads")
local POCKET_VERSION = "v0.13.0-beta" local POCKET_VERSION = "v0.13.1-beta"
local println = util.println local println = util.println
local println_ts = util.println_ts local println_ts = util.println_ts

View File

@ -592,7 +592,7 @@ function system.create(tool_ctl, main_pane, cfg_sys, divs, style, exit)
local c = util.trinary(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white)) local c = util.trinary(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white))
alternate = not alternate alternate = not alternate
if string.len(val) > val_max_w then if (string.len(val) > val_max_w) or string.find(val, "\n") then
local lines = util.strwrap(val, inner_width) local lines = util.strwrap(val, inner_width)
height = #lines + 1 height = #lines + 1
end end

View File

@ -40,6 +40,8 @@ local function init(panel)
local disabled_fg = style.fp.disabled_fg local disabled_fg = style.fp.disabled_fg
local term_w, term_h = term.getSize()
local header = TextBox{parent=panel,y=1,text="FISSION REACTOR PLC - UNIT ?",alignment=ALIGN.CENTER,fg_bg=style.theme.header} local header = TextBox{parent=panel,y=1,text="FISSION REACTOR PLC - UNIT ?",alignment=ALIGN.CENTER,fg_bg=style.theme.header}
header.register(databus.ps, "unit_id", function (id) header.set_value(util.c("FISSION REACTOR PLC - UNIT ", id)) end) header.register(databus.ps, "unit_id", function (id) header.set_value(util.c("FISSION REACTOR PLC - UNIT ", id)) end)
@ -60,7 +62,7 @@ local function init(panel)
local modem = LED{parent=system,label="MODEM",colors=ind_grn} local modem = LED{parent=system,label="MODEM",colors=ind_grn}
if not style.colorblind then if not style.colorblind then
local network = RGBLED{parent=system,label="NETWORK",colors={colors.green,colors.red,colors.orange,colors.yellow,style.ind_bkg}} local network = RGBLED{parent=system,label="NETWORK",colors={colors.green,colors.red,colors.yellow,colors.orange,style.ind_bkg}}
network.update(types.PANEL_LINK_STATE.DISCONNECTED) network.update(types.PANEL_LINK_STATE.DISCONNECTED)
network.register(databus.ps, "link_state", network.update) network.register(databus.ps, "link_state", network.update)
else else
@ -121,7 +123,7 @@ local function init(panel)
-- status & controls -- status & controls
-- --
local status = Div{parent=panel,width=19,height=18,x=17,y=3} local status = Div{parent=panel,width=term_w-32,height=18,x=17,y=3}
local active = LED{parent=status,x=2,width=12,label="RCT ACTIVE",colors=ind_grn} local active = LED{parent=status,x=2,width=12,label="RCT ACTIVE",colors=ind_grn}
@ -131,14 +133,15 @@ local function init(panel)
emer_cool.register(databus.ps, "emer_cool", emer_cool.update) emer_cool.register(databus.ps, "emer_cool", emer_cool.update)
end end
local status_trip_rct = Rectangle{parent=status,width=20,height=3,x=1,border=border(1,s_hi_box.bkg,true),even_inner=true} local status_trip_rct = Rectangle{parent=status,height=3,x=1,border=border(1,s_hi_box.bkg,true),even_inner=true}
local status_trip = Div{parent=status_trip_rct,width=18,height=1,fg_bg=s_hi_box} local status_trip = Div{parent=status_trip_rct,height=1,fg_bg=s_hi_box}
local scram = LED{parent=status_trip,width=10,label="RPS TRIP",colors=ind_red,flash=true,period=flasher.PERIOD.BLINK_250_MS} local scram = LED{parent=status_trip,width=10,label="RPS TRIP",colors=ind_red,flash=true,period=flasher.PERIOD.BLINK_250_MS}
local controls_rct = Rectangle{parent=status,width=17,height=3,x=1,border=border(1,s_hi_box.bkg,true),even_inner=true} local controls_rct = Rectangle{parent=status,width=status.get_width()-2,height=3,x=1,border=border(1,s_hi_box.bkg,true),even_inner=true}
local controls = Div{parent=controls_rct,width=15,height=1,fg_bg=s_hi_box} local controls = Div{parent=controls_rct,width=controls_rct.get_width()-2,height=1,fg_bg=s_hi_box}
PushButton{parent=controls,x=1,y=1,min_width=7,text="SCRAM",callback=databus.rps_scram,fg_bg=cpair(colors.black,colors.red),active_fg_bg=cpair(colors.black,colors.red_off)} local button_padding = math.floor((controls.get_width() - 14) / 3)
PushButton{parent=controls,x=9,y=1,min_width=7,text="RESET",callback=databus.rps_reset,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=cpair(colors.black,colors.yellow_off)} PushButton{parent=controls,x=button_padding+1,y=1,min_width=7,text="SCRAM",callback=databus.rps_scram,fg_bg=cpair(colors.black,colors.red),active_fg_bg=cpair(colors.black,colors.red_off)}
PushButton{parent=controls,x=(2*button_padding)+9,y=1,min_width=7,text="RESET",callback=databus.rps_reset,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=cpair(colors.black,colors.yellow_off)}
active.register(databus.ps, "reactor_active", active.update) active.register(databus.ps, "reactor_active", active.update)
scram.register(databus.ps, "rps_scram", scram.update) scram.register(databus.ps, "rps_scram", scram.update)
@ -147,9 +150,9 @@ local function init(panel)
-- about footer -- about footer
-- --
local about = Div{parent=panel,width=15,height=3,x=1,y=18,fg_bg=disabled_fg} local about = Div{parent=panel,width=15,height=2,y=term_h-1,fg_bg=disabled_fg}
local fw_v = TextBox{parent=about,x=1,y=1,text="FW: v00.00.00"} local fw_v = TextBox{parent=about,text="FW: v00.00.00"}
local comms_v = TextBox{parent=about,x=1,y=2,text="NT: v00.00.00"} local comms_v = TextBox{parent=about,text="NT: v00.00.00"}
fw_v.register(databus.ps, "version", function (version) fw_v.set_value(util.c("FW: ", version)) end) fw_v.register(databus.ps, "version", function (version) fw_v.set_value(util.c("FW: ", version)) end)
comms_v.register(databus.ps, "comms_version", function (version) comms_v.set_value(util.c("NT: v", version)) end) comms_v.register(databus.ps, "comms_version", function (version) comms_v.set_value(util.c("NT: v", version)) end)
@ -158,7 +161,7 @@ local function init(panel)
-- rps list -- rps list
-- --
local rps = Rectangle{parent=panel,width=16,height=16,x=36,y=3,border=border(1,s_hi_box.bkg),thin=true,fg_bg=s_hi_box} local rps = Rectangle{parent=panel,width=16,height=16,x=term_w-15,y=3,border=border(1,s_hi_box.bkg),thin=true,fg_bg=s_hi_box}
local rps_man = LED{parent=rps,label="MANUAL",colors=ind_red} local rps_man = LED{parent=rps,label="MANUAL",colors=ind_red}
local rps_auto = LED{parent=rps,label="AUTOMATIC",colors=ind_red} local rps_auto = LED{parent=rps,label="AUTOMATIC",colors=ind_red}
local rps_tmo = LED{parent=rps,label="TIMEOUT",colors=ind_red} local rps_tmo = LED{parent=rps,label="TIMEOUT",colors=ind_red}

View File

@ -23,8 +23,7 @@ local AUTO_ACK = comms.PLC_AUTO_ACK
local RPS_LIMITS = const.RPS_LIMITS local RPS_LIMITS = const.RPS_LIMITS
-- I sure hope the devs don't change this error message, not that it would have safety implications -- specific errors thrown when scram/start is used that still count as success
-- I wish they didn't change it to be like this
local PCALL_SCRAM_MSG = "Scram requires the reactor to be active." local PCALL_SCRAM_MSG = "Scram requires the reactor to be active."
local PCALL_START_MSG = "Reactor is already active." local PCALL_START_MSG = "Reactor is already active."

View File

@ -18,7 +18,7 @@ local plc = require("reactor-plc.plc")
local renderer = require("reactor-plc.renderer") local renderer = require("reactor-plc.renderer")
local threads = require("reactor-plc.threads") local threads = require("reactor-plc.threads")
local R_PLC_VERSION = "v1.8.14" local R_PLC_VERSION = "v1.8.19"
local println = util.println local println = util.println
local println_ts = util.println_ts local println_ts = util.println_ts
@ -169,12 +169,12 @@ local function main()
-- PLC init<br> -- PLC init<br>
--- EVENT_CONSUMER: this function consumes events --- EVENT_CONSUMER: this function consumes events
local function init() local function init()
-- just booting up, no fission allowed (neutrons stay put thanks) -- scram on boot if networked, otherwise leave the reactor be
if (not plc_state.no_reactor) and plc_state.reactor_formed and smem_dev.reactor.getStatus() then if __shared_memory.networked and (not plc_state.no_reactor) and plc_state.reactor_formed and smem_dev.reactor.getStatus() then
smem_dev.reactor.scram() smem_dev.reactor.scram()
end end
-- front panel time! -- setup front panel
if not renderer.ui_ready() then if not renderer.ui_ready() then
local message local message
plc_state.fp_ok, message = renderer.try_start_ui(config.FrontPanelTheme, config.ColorMode) plc_state.fp_ok, message = renderer.try_start_ui(config.FrontPanelTheme, config.ColorMode)

View File

@ -149,7 +149,7 @@ function peripherals.create(tool_ctl, main_pane, cfg_sys, peri_cfg, style)
reposition("This SNA is for reactor unit # .", 46, 1, 31, 4, 7) reposition("This SNA is for reactor unit # .", 46, 1, 31, 4, 7)
self.p_idx.hide() self.p_idx.hide()
self.p_assign_btn.hide(true) self.p_assign_btn.hide(true)
self.p_desc_ext.set_value("Before adding lots of SNAs: multiply the \"PEAK\" rate on the flow monitor (after connecting at least 1 SNA) by 10 to get the mB/t of waste that they can process. Enough SNAs to provide 2x to 3x of your max burn rate should be a good margin to catch up after night or cloudy weather. Too many devices (such as SNAs) on one RTU can cause lag.") self.p_desc_ext.set_value("Warning: too many devices on one RTU Gateway can cause lag. Note that 10x the \"PEAK\x1a\" rate on the flow monitor gives you the mB/t of waste that the SNA(s) can process. Enough SNAs to provide 2x to 3x of that unit's max burn rate should be a good margin to catch up after night or cloudy weather.")
elseif type == "dynamicValve" then elseif type == "dynamicValve" then
reposition("This is the below system's # dynamic tank.", 29, 4, 17, 6, 8) reposition("This is the below system's # dynamic tank.", 29, 4, 17, 6, 8)
self.p_assign_btn.show() self.p_assign_btn.show()

View File

@ -74,11 +74,12 @@ local PORT_DESC_MAP = {
{ IO.R_PLC_FAULT, "RPS PLC Fault" }, { IO.R_PLC_FAULT, "RPS PLC Fault" },
{ IO.R_PLC_TIMEOUT, "RPS Supervisor Timeout" }, { IO.R_PLC_TIMEOUT, "RPS Supervisor Timeout" },
{ IO.U_ALARM, "Unit Alarm" }, { IO.U_ALARM, "Unit Alarm" },
{ IO.U_EMER_COOL, "Unit Emergency Cool. Valve" } { IO.U_EMER_COOL, "Unit Emergency Cool. Valve" },
{ IO.U_AUX_COOL, "Unit Auxiliary Cool. Valve" }
} }
-- designation (0 = facility, 1 = unit) -- designation (0 = facility, 1 = unit)
local PORT_DSGN = { [-1] = 1, 0, 0, 1, 1, 1, 1, 0, 0, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 0, 0, 0 } local PORT_DSGN = { [-1] = 1, 0, 0, 1, 1, 1, 1, 0, 0, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 0, 0, 0, 1 }
assert(#PORT_DESC_MAP == rsio.NUM_PORTS) assert(#PORT_DESC_MAP == rsio.NUM_PORTS)
assert(#PORT_DSGN == rsio.NUM_PORTS) assert(#PORT_DSGN == rsio.NUM_PORTS)

View File

@ -646,7 +646,7 @@ function system.create(tool_ctl, main_pane, cfg_sys, divs, ext, style)
local c = tri(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white)) local c = tri(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white))
alternate = not alternate alternate = not alternate
if string.len(val) > val_max_w then if (string.len(val) > val_max_w) or string.find(val, "\n") then
local lines = util.strwrap(val, inner_width) local lines = util.strwrap(val, inner_width)
height = #lines + 1 height = #lines + 1
end end

View File

@ -35,13 +35,15 @@ local UNIT_TYPE_LABELS = { "UNKNOWN", "REDSTONE", "BOILER", "TURBINE", "DYNAMIC
local function init(panel, units) local function init(panel, units)
local disabled_fg = style.fp.disabled_fg local disabled_fg = style.fp.disabled_fg
local term_w, term_h = term.getSize()
TextBox{parent=panel,y=1,text="RTU GATEWAY",alignment=ALIGN.CENTER,fg_bg=style.theme.header} TextBox{parent=panel,y=1,text="RTU GATEWAY",alignment=ALIGN.CENTER,fg_bg=style.theme.header}
-- --
-- system indicators -- system indicators
-- --
local system = Div{parent=panel,width=14,height=18,x=2,y=3} local system = Div{parent=panel,width=14,height=term_h-5,x=2,y=3}
local on = LED{parent=system,label="STATUS",colors=cpair(colors.green,colors.red)} local on = LED{parent=system,label="STATUS",colors=cpair(colors.green,colors.red)}
local heartbeat = LED{parent=system,label="HEARTBEAT",colors=ind_grn} local heartbeat = LED{parent=system,label="HEARTBEAT",colors=ind_grn}
@ -53,7 +55,7 @@ local function init(panel, units)
local modem = LED{parent=system,label="MODEM",colors=ind_grn} local modem = LED{parent=system,label="MODEM",colors=ind_grn}
if not style.colorblind then if not style.colorblind then
local network = RGBLED{parent=system,label="NETWORK",colors={colors.green,colors.red,colors.orange,colors.yellow,style.ind_bkg}} local network = RGBLED{parent=system,label="NETWORK",colors={colors.green,colors.red,colors.yellow,colors.orange,style.ind_bkg}}
network.update(types.PANEL_LINK_STATE.DISCONNECTED) network.update(types.PANEL_LINK_STATE.DISCONNECTED)
network.register(databus.ps, "link_state", network.update) network.register(databus.ps, "link_state", network.update)
else else
@ -100,17 +102,17 @@ local function init(panel, units)
local comp_id = util.sprintf("(%d)", os.getComputerID()) local comp_id = util.sprintf("(%d)", os.getComputerID())
TextBox{parent=system,x=9,y=4,width=6,text=comp_id,fg_bg=disabled_fg} TextBox{parent=system,x=9,y=4,width=6,text=comp_id,fg_bg=disabled_fg}
TextBox{parent=system,x=1,y=14,text="SPEAKERS",width=8,fg_bg=style.fp.text_fg} TextBox{parent=system,y=term_h-5,text="SPEAKERS",width=8,fg_bg=style.fp.text_fg}
local speaker_count = DataIndicator{parent=system,x=10,y=14,label="",format="%3d",value=0,width=3,fg_bg=style.theme.field_box} local speaker_count = DataIndicator{parent=system,x=10,y=term_h-5,label="",format="%3d",value=0,width=3,fg_bg=style.theme.field_box}
speaker_count.register(databus.ps, "speaker_count", speaker_count.update) speaker_count.register(databus.ps, "speaker_count", speaker_count.update)
-- --
-- about label -- about label
-- --
local about = Div{parent=panel,width=15,height=3,x=1,y=18,fg_bg=disabled_fg} local about = Div{parent=panel,width=15,height=2,y=term_h-1,fg_bg=disabled_fg}
local fw_v = TextBox{parent=about,x=1,y=1,text="FW: v00.00.00"} local fw_v = TextBox{parent=about,text="FW: v00.00.00"}
local comms_v = TextBox{parent=about,x=1,y=2,text="NT: v00.00.00"} local comms_v = TextBox{parent=about,text="NT: v00.00.00"}
fw_v.register(databus.ps, "version", function (version) fw_v.set_value(util.c("FW: ", version)) end) fw_v.register(databus.ps, "version", function (version) fw_v.set_value(util.c("FW: ", version)) end)
comms_v.register(databus.ps, "comms_version", function (version) comms_v.set_value(util.c("NT: v", version)) end) comms_v.register(databus.ps, "comms_version", function (version) comms_v.set_value(util.c("NT: v", version)) end)
@ -119,10 +121,10 @@ local function init(panel, units)
-- unit status list -- unit status list
-- --
local threads = Div{parent=panel,width=8,height=18,x=17,y=3} local threads = Div{parent=panel,width=8,height=term_h-3,x=17,y=3}
-- display up to 16 units -- display as many units as we can with 1 line of padding above and below
local list_length = math.min(#units, 16) local list_length = math.min(#units, term_h - 3)
-- show routine statuses -- show routine statuses
for i = 1, list_length do for i = 1, list_length do
@ -131,7 +133,7 @@ local function init(panel, units)
rt_unit.register(databus.ps, "routine__unit_" .. i, rt_unit.update) rt_unit.register(databus.ps, "routine__unit_" .. i, rt_unit.update)
end end
local unit_hw_statuses = Div{parent=panel,height=18,x=25,y=3} local unit_hw_statuses = Div{parent=panel,height=term_h-3,x=25,y=3}
-- show hardware statuses -- show hardware statuses
for i = 1, list_length do for i = 1, list_length do
@ -150,7 +152,7 @@ local function init(panel, units)
-- assignment (unit # or facility) -- assignment (unit # or facility)
local for_unit = util.trinary(unit.reactor == 0, "\x1a FACIL ", "\x1a UNIT " .. unit.reactor) local for_unit = util.trinary(unit.reactor == 0, "\x1a FACIL ", "\x1a UNIT " .. unit.reactor)
TextBox{parent=unit_hw_statuses,y=i,x=19,text=for_unit,fg_bg=disabled_fg} TextBox{parent=unit_hw_statuses,y=i,x=term_w-32,text=for_unit,fg_bg=disabled_fg}
end end
end end

View File

@ -31,7 +31,7 @@ local sna_rtu = require("rtu.dev.sna_rtu")
local sps_rtu = require("rtu.dev.sps_rtu") local sps_rtu = require("rtu.dev.sps_rtu")
local turbinev_rtu = require("rtu.dev.turbinev_rtu") local turbinev_rtu = require("rtu.dev.turbinev_rtu")
local RTU_VERSION = "v1.11.0" local RTU_VERSION = "v1.11.6"
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local RTU_HW_STATE = databus.RTU_HW_STATE local RTU_HW_STATE = databus.RTU_HW_STATE

View File

@ -17,7 +17,7 @@ local max_distance = nil
local comms = {} local comms = {}
-- protocol/data versions (protocol/data independent changes tracked by util.lua version) -- protocol/data versions (protocol/data independent changes tracked by util.lua version)
comms.version = "3.0.4" comms.version = "3.0.5"
comms.api_version = "0.0.9" comms.api_version = "0.0.9"
---@enum PROTOCOL ---@enum PROTOCOL
@ -60,18 +60,19 @@ local MGMT_TYPE = {
---@enum CRDN_TYPE ---@enum CRDN_TYPE
local CRDN_TYPE = { local CRDN_TYPE = {
INITIAL_BUILDS = 0, -- initial, complete builds packet to the coordinator INITIAL_BUILDS = 0, -- initial, complete builds packet to the coordinator
FAC_BUILDS = 1, -- facility RTU builds PROCESS_READY = 1, -- process init is complete + last set of info for supervisor startup recovery
FAC_STATUS = 2, -- state of facility and facility devices FAC_BUILDS = 2, -- facility RTU builds
FAC_CMD = 3, -- faility command FAC_STATUS = 3, -- state of facility and facility devices
UNIT_BUILDS = 4, -- build of each reactor unit (reactor + RTUs) FAC_CMD = 4, -- faility command
UNIT_STATUSES = 5, -- state of each of the reactor units UNIT_BUILDS = 5, -- build of each reactor unit (reactor + RTUs)
UNIT_CMD = 6, -- command a reactor unit UNIT_STATUSES = 6, -- state of each of the reactor units
API_GET_FAC = 7, -- API: get the facility general data UNIT_CMD = 7, -- command a reactor unit
API_GET_FAC_DTL = 8, -- API: get (detailed) data for the facility app API_GET_FAC = 8, -- API: get the facility general data
API_GET_UNIT = 9, -- API: get reactor unit data API_GET_FAC_DTL = 9, -- API: get (detailed) data for the facility app
API_GET_CTRL = 10, -- API: get data for the control app API_GET_UNIT = 10, -- API: get reactor unit data
API_GET_PROC = 11, -- API: get data for the process app API_GET_CTRL = 11, -- API: get data for the control app
API_GET_WASTE = 12 -- API: get data for the waste app API_GET_PROC = 12, -- API: get data for the process app
API_GET_WASTE = 13 -- API: get data for the waste app
} }
---@enum ESTABLISH_ACK ---@enum ESTABLISH_ACK

View File

@ -72,6 +72,8 @@ local rs = {}
rs.IMATRIX_CHARGE_LOW = 0.05 -- activation threshold (less than) for F_MATRIX_LOW rs.IMATRIX_CHARGE_LOW = 0.05 -- activation threshold (less than) for F_MATRIX_LOW
rs.IMATRIX_CHARGE_HIGH = 0.95 -- activation threshold (greater than) for F_MATRIX_HIGH rs.IMATRIX_CHARGE_HIGH = 0.95 -- activation threshold (greater than) for F_MATRIX_HIGH
rs.AUX_COOL_ENABLE = 0.60 -- actiation threshold (less than or equal) for U_AUX_COOL
rs.AUX_COOL_DISABLE = 1.00 -- deactivation threshold (greater than or equal) for U_AUX_COOL
constants.RS_THRESHOLDS = rs constants.RS_THRESHOLDS = rs

View File

@ -78,6 +78,7 @@ local IO_PORT = {
-- unit outputs -- unit outputs
U_ALARM = 25, -- active high, unit alarm U_ALARM = 25, -- active high, unit alarm
U_EMER_COOL = 26, -- active low, emergency coolant control U_EMER_COOL = 26, -- active low, emergency coolant control
U_AUX_COOL = 30, -- active low, auxiliary coolant control
-- analog outputs -- -- analog outputs --
@ -90,8 +91,8 @@ rsio.IO_DIR = IO_DIR
rsio.IO_MODE = IO_MODE rsio.IO_MODE = IO_MODE
rsio.IO = IO_PORT rsio.IO = IO_PORT
rsio.NUM_PORTS = 29 rsio.NUM_PORTS = 30
rsio.NUM_DIG_PORTS = 28 rsio.NUM_DIG_PORTS = 29
rsio.NUM_ANA_PORTS = 1 rsio.NUM_ANA_PORTS = 1
-- self checks -- self checks
@ -149,6 +150,7 @@ local MODES = {
[IO.R_PLC_TIMEOUT] = IO_MODE.DIGITAL_OUT, [IO.R_PLC_TIMEOUT] = IO_MODE.DIGITAL_OUT,
[IO.U_ALARM] = IO_MODE.DIGITAL_OUT, [IO.U_ALARM] = IO_MODE.DIGITAL_OUT,
[IO.U_EMER_COOL] = IO_MODE.DIGITAL_OUT, [IO.U_EMER_COOL] = IO_MODE.DIGITAL_OUT,
[IO.U_AUX_COOL] = IO_MODE.DIGITAL_OUT,
[IO.F_MATRIX_CHG] = IO_MODE.ANALOG_OUT [IO.F_MATRIX_CHG] = IO_MODE.ANALOG_OUT
} }
@ -208,10 +210,11 @@ local RS_DIO_MAP = {
[IO.R_PLC_TIMEOUT] = { _in = _I_ACTIVE_HIGH, _out = _O_ACTIVE_HIGH, mode = IO_DIR.OUT }, [IO.R_PLC_TIMEOUT] = { _in = _I_ACTIVE_HIGH, _out = _O_ACTIVE_HIGH, mode = IO_DIR.OUT },
[IO.U_ALARM] = { _in = _I_ACTIVE_HIGH, _out = _O_ACTIVE_HIGH, mode = IO_DIR.OUT }, [IO.U_ALARM] = { _in = _I_ACTIVE_HIGH, _out = _O_ACTIVE_HIGH, mode = IO_DIR.OUT },
[IO.U_EMER_COOL] = { _in = _I_ACTIVE_LOW, _out = _O_ACTIVE_LOW, mode = IO_DIR.OUT } [IO.U_EMER_COOL] = { _in = _I_ACTIVE_LOW, _out = _O_ACTIVE_LOW, mode = IO_DIR.OUT },
[IO.U_AUX_COOL] = { _in = _I_ACTIVE_LOW, _out = _O_ACTIVE_LOW, mode = IO_DIR.OUT }
} }
assert(rsio.NUM_DIG_PORTS == #RS_DIO_MAP, "RS_DIO_MAP length incorrect") assert(rsio.NUM_DIG_PORTS == util.table_len(RS_DIO_MAP), "RS_DIO_MAP length incorrect")
-- get the I/O direction of a port -- get the I/O direction of a port
---@nodiscard ---@nodiscard

View File

@ -24,7 +24,7 @@ local t_pack = table.pack
local util = {} local util = {}
-- scada-common version -- scada-common version
util.version = "1.4.10" util.version = "1.4.12"
util.TICK_TIME_S = 0.05 util.TICK_TIME_S = 0.05
util.TICK_TIME_MS = 50 util.TICK_TIME_MS = 50

View File

@ -185,8 +185,9 @@ function facility.create(tool_ctl, main_pane, cfg_sys, fac_cfg, style)
local fac_c_6 = Div{parent=fac_cfg,x=2,y=4,width=49} local fac_c_6 = Div{parent=fac_cfg,x=2,y=4,width=49}
local fac_c_7 = Div{parent=fac_cfg,x=2,y=4,width=49} local fac_c_7 = Div{parent=fac_cfg,x=2,y=4,width=49}
local fac_c_8 = Div{parent=fac_cfg,x=2,y=4,width=49} local fac_c_8 = Div{parent=fac_cfg,x=2,y=4,width=49}
local fac_c_9 = Div{parent=fac_cfg,x=2,y=4,width=49}
local fac_pane = MultiPane{parent=fac_cfg,x=1,y=4,panes={fac_c_1,fac_c_2,fac_c_3,fac_c_4,fac_c_5,fac_c_6,fac_c_7, fac_c_8}} local fac_pane = MultiPane{parent=fac_cfg,x=1,y=4,panes={fac_c_1,fac_c_2,fac_c_3,fac_c_4,fac_c_5,fac_c_6,fac_c_7,fac_c_8,fac_c_9}}
TextBox{parent=fac_cfg,x=1,y=2,text=" Facility Configuration",fg_bg=cpair(colors.black,colors.yellow)} TextBox{parent=fac_cfg,x=1,y=2,text=" Facility Configuration",fg_bg=cpair(colors.black,colors.yellow)}
@ -205,10 +206,18 @@ function facility.create(tool_ctl, main_pane, cfg_sys, fac_cfg, style)
nu_error.hide(true) nu_error.hide(true)
tmp_cfg.UnitCount = count tmp_cfg.UnitCount = count
local confs = tool_ctl.cooling_elems local c_confs = tool_ctl.cooling_elems
if count >= 2 then confs[2].line.show() else confs[2].line.hide(true) end local a_confs = tool_ctl.aux_cool_elems
if count >= 3 then confs[3].line.show() else confs[3].line.hide(true) end
if count == 4 then confs[4].line.show() else confs[4].line.hide(true) end for i = 2, 4 do
if count >= i then
c_confs[i].line.show()
a_confs[i].line.show()
else
c_confs[i].line.hide(true)
a_confs[i].line.hide(true)
end
end
fac_pane.set_value(2) fac_pane.set_value(2)
else nu_error.show() end else nu_error.show() end
@ -285,6 +294,14 @@ function facility.create(tool_ctl, main_pane, cfg_sys, fac_cfg, style)
else elem.div.hide(true) end else elem.div.hide(true) end
end end
if not any_has_tank then
tmp_cfg.FacilityTankMode = 0
tmp_cfg.FacilityTankDefs = {}
tmp_cfg.FacilityTankList = {}
tmp_cfg.FacilityTankConns = {}
tmp_cfg.TankFluidTypes = {}
end
if any_has_tank then fac_pane.set_value(3) else main_pane.set_value(3) end if any_has_tank then fac_pane.set_value(3) else main_pane.set_value(3) end
end end
end end
@ -672,25 +689,48 @@ function facility.create(tool_ctl, main_pane, cfg_sys, fac_cfg, style)
PushButton{parent=fac_c_7,x=1,y=14,text="\x1b Back",callback=back_from_fluids,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg} PushButton{parent=fac_c_7,x=1,y=14,text="\x1b Back",callback=back_from_fluids,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
PushButton{parent=fac_c_7,x=44,y=14,text="Next \x1a",callback=submit_tank_fluids,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg} PushButton{parent=fac_c_7,x=44,y=14,text="Next \x1a",callback=submit_tank_fluids,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
--#endregion
--#region Auxiliary Coolant
TextBox{parent=fac_c_8,height=5,text="Auxiliary water coolant can be enabled for units to provide extra water during turbine ramp-up. For water cooled reactors, this goes to the reactor. For sodium cooled reactors, water goes to the boiler."}
for i = 1, 4 do
local line = Div{parent=fac_c_8,x=1,y=7+i,height=1}
TextBox{parent=line,text="Unit "..i.." -",width=8}
local aux_cool = Checkbox{parent=line,x=10,y=1,label="Has Auxiliary Coolant",default=ini_cfg.AuxiliaryCoolant[i],box_fg_bg=cpair(colors.yellow,colors.black)}
tool_ctl.aux_cool_elems[i] = { line = line, enable = aux_cool }
end
local function submit_aux_cool()
tmp_cfg.AuxiliaryCoolant = {}
for i = 1, tmp_cfg.UnitCount do
tmp_cfg.AuxiliaryCoolant[i] = tool_ctl.aux_cool_elems[i].enable.get_value()
end
fac_pane.set_value(9)
end
PushButton{parent=fac_c_8,x=1,y=14,text="\x1b Back",callback=function()fac_pane.set_value(7)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
PushButton{parent=fac_c_8,x=44,y=14,text="Next \x1a",callback=submit_aux_cool,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
--#endregion --#endregion
--#region Extended Idling --#region Extended Idling
TextBox{parent=fac_c_8,height=6,text="Charge control provides automatic control to maintain an induction matrix charge level. In order to have smoother control, reactors that were activated will be held on at 0.01 mB/t for a short period before allowing them to turn off. This minimizes overshooting the charge target."} TextBox{parent=fac_c_9,height=6,text="Charge control provides automatic control to maintain an induction matrix charge level. In order to have smoother control, reactors that were activated will be held on at 0.01 mB/t for a short period before allowing them to turn off. This minimizes overshooting the charge target."}
TextBox{parent=fac_c_8,y=8,height=3,text="You can extend this to a full minute to minimize reactors flickering on/off, but there may be more overshoot of the target."} TextBox{parent=fac_c_9,y=8,height=3,text="You can extend this to a full minute to minimize reactors flickering on/off, but there may be more overshoot of the target."}
local ext_idling = Checkbox{parent=fac_c_8,x=1,y=12,label="Enable Extended Idling",default=ini_cfg.ExtChargeIdling,box_fg_bg=cpair(colors.yellow,colors.black)} local ext_idling = Checkbox{parent=fac_c_9,x=1,y=12,label="Enable Extended Idling",default=ini_cfg.ExtChargeIdling,box_fg_bg=cpair(colors.yellow,colors.black)}
local function back_from_idling()
fac_pane.set_value(tri(tmp_cfg.FacilityTankMode == 0, 3, 7))
end
local function submit_idling() local function submit_idling()
tmp_cfg.ExtChargeIdling = ext_idling.get_value() tmp_cfg.ExtChargeIdling = ext_idling.get_value()
main_pane.set_value(3) main_pane.set_value(3)
end end
PushButton{parent=fac_c_8,x=1,y=14,text="\x1b Back",callback=back_from_idling,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg} PushButton{parent=fac_c_9,x=1,y=14,text="\x1b Back",callback=function()fac_pane.set_value(8)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
PushButton{parent=fac_c_8,x=44,y=14,text="Next \x1a",callback=submit_idling,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg} PushButton{parent=fac_c_9,x=44,y=14,text="Next \x1a",callback=submit_idling,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
--#endregion --#endregion

View File

@ -402,6 +402,10 @@ function system.create(tool_ctl, main_pane, cfg_sys, divs, fac_pane, style, exit
try_set(tool_ctl.tank_elems[i].tank_opt, ini_cfg.FacilityTankDefs[i]) try_set(tool_ctl.tank_elems[i].tank_opt, ini_cfg.FacilityTankDefs[i])
end end
for i = 1, #ini_cfg.AuxiliaryCoolant do
try_set(tool_ctl.aux_cool_elems[i].enable, ini_cfg.AuxiliaryCoolant[i])
end
tool_ctl.en_fac_tanks.set_value(ini_cfg.FacilityTankMode > 0) tool_ctl.en_fac_tanks.set_value(ini_cfg.FacilityTankMode > 0)
tool_ctl.view_cfg.enable() tool_ctl.view_cfg.enable()
@ -588,7 +592,7 @@ function system.create(tool_ctl, main_pane, cfg_sys, divs, fac_pane, style, exit
end end
if val == "" then val = "no facility tanks" end if val == "" then val = "no facility tanks" end
elseif f[1] == "FacilityTankMode" and raw == 0 then val = "0 (n/a, unit mode)" elseif f[1] == "FacilityTankMode" and raw == 0 then val = "no facility tanks"
elseif f[1] == "FacilityTankDefs" and type(cfg.FacilityTankDefs) == "table" then elseif f[1] == "FacilityTankDefs" and type(cfg.FacilityTankDefs) == "table" then
local tank_name_list = { table.unpack(cfg.FacilityTankList) } ---@type (string|integer)[] local tank_name_list = { table.unpack(cfg.FacilityTankList) } ---@type (string|integer)[]
local next_f = 1 local next_f = 1
@ -625,6 +629,13 @@ function system.create(tool_ctl, main_pane, cfg_sys, divs, fac_pane, style, exit
val = "" val = ""
local count = 0
for idx = 1, #tank_list do
if tank_list[idx] > 0 then count = count + 1 end
end
local bullet = tri(count < 2, "", " \x07 ")
for idx = 1, #tank_list do for idx = 1, #tank_list do
local prefix = "?" local prefix = "?"
local fluid = "water" local fluid = "water"
@ -642,11 +653,28 @@ function system.create(tool_ctl, main_pane, cfg_sys, divs, fac_pane, style, exit
fluid = "sodium" fluid = "sodium"
end end
val = val .. tri(val == "", "", "\n") .. util.sprintf(" \x07 tank %s - %s", prefix, fluid) val = val .. tri(val == "", "", "\n") .. util.sprintf(bullet .. "tank %s - %s", prefix, fluid)
end end
end end
if val == "" then val = "no emergency coolant tanks" end if val == "" then val = "no emergency coolant tanks" end
elseif f[1] == "AuxiliaryCoolant" then
val = ""
local count = 0
for idx = 1, #cfg.AuxiliaryCoolant do
if cfg.AuxiliaryCoolant[idx] then count = count + 1 end
end
local bullet = tri(count < 2, "", " \x07 ")
for idx = 1, #cfg.AuxiliaryCoolant do
if cfg.AuxiliaryCoolant[idx] then
val = val .. tri(val == "", "", "\n") .. util.sprintf(bullet .. "unit %d", idx)
end
end
if val == "" then val = "no auxiliary coolant" end
end end
if not skip then if not skip then
@ -655,7 +683,7 @@ function system.create(tool_ctl, main_pane, cfg_sys, divs, fac_pane, style, exit
local c = tri(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white)) local c = tri(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white))
alternate = not alternate alternate = not alternate
if string.len(val) > val_max_w then if (string.len(val) > val_max_w) or string.find(val, "\n") then
local lines = util.strwrap(val, inner_width) local lines = util.strwrap(val, inner_width)
height = #lines + 1 height = #lines + 1
end end

View File

@ -72,7 +72,8 @@ local tool_ctl = {
load_legacy = nil, ---@type function load_legacy = nil, ---@type function
cooling_elems = {}, ---@type { line: Div, turbines: NumberField, boilers: NumberField, tank: Checkbox }[] cooling_elems = {}, ---@type { line: Div, turbines: NumberField, boilers: NumberField, tank: Checkbox }[]
tank_elems = {} ---@type { div: Div, tank_opt: Radio2D, no_tank: TextBox }[] tank_elems = {}, ---@type { div: Div, tank_opt: Radio2D, no_tank: TextBox }[]
aux_cool_elems = {} ---@type { line: Div, enable: Checkbox }[]
} }
---@class svr_config ---@class svr_config
@ -84,6 +85,7 @@ local tmp_cfg = {
FacilityTankList = {}, ---@type integer[] list of tanks by slot (0 = none or covered by an above tank, 1 = unit tank, 2 = facility tank) FacilityTankList = {}, ---@type integer[] list of tanks by slot (0 = none or covered by an above tank, 1 = unit tank, 2 = facility tank)
FacilityTankConns = {}, ---@type integer[] map of unit tank connections (indicies are units, values are tank indicies in the tank list) FacilityTankConns = {}, ---@type integer[] map of unit tank connections (indicies are units, values are tank indicies in the tank list)
TankFluidTypes = {}, ---@type integer[] which type of fluid each tank in the tank list should be containing TankFluidTypes = {}, ---@type integer[] which type of fluid each tank in the tank list should be containing
AuxiliaryCoolant = {}, ---@type boolean[] if a unit has auxiliary coolant
ExtChargeIdling = false, ExtChargeIdling = false,
SVR_Channel = nil, ---@type integer SVR_Channel = nil, ---@type integer
PLC_Channel = nil, ---@type integer PLC_Channel = nil, ---@type integer
@ -117,6 +119,7 @@ local fields = {
{ "FacilityTankList", "Facility Tank List", {} }, -- hidden { "FacilityTankList", "Facility Tank List", {} }, -- hidden
{ "FacilityTankConns", "Facility Tank Connections", {} }, -- hidden { "FacilityTankConns", "Facility Tank Connections", {} }, -- hidden
{ "TankFluidTypes", "Tank Fluid Types", {} }, { "TankFluidTypes", "Tank Fluid Types", {} },
{ "AuxiliaryCoolant", "Auxiliary Water Coolant", {} },
{ "ExtChargeIdling", "Extended Charge Idling", false }, { "ExtChargeIdling", "Extended Charge Idling", false },
{ "SVR_Channel", "SVR Channel", 16240 }, { "SVR_Channel", "SVR Channel", 16240 },
{ "PLC_Channel", "PLC Channel", 16241 }, { "PLC_Channel", "PLC Channel", 16241 },

View File

@ -31,6 +31,17 @@ local START_STATUS = {
BLADE_MISMATCH = 2 BLADE_MISMATCH = 2
} }
---@enum RECOVERY_STATE
local RCV_STATE = {
INACTIVE = 0,
PRIMED = 1,
RUNNING = 2,
STOPPED = 3
}
local CHARGE_SCALER = 1000000 -- convert MFE to FE
local GEN_SCALER = 1000 -- convert kFE to FE
---@class facility_management ---@class facility_management
local facility = {} local facility = {}
@ -41,7 +52,7 @@ function facility.new(config)
---@class _facility_self ---@class _facility_self
local self = { local self = {
units = {}, ---@type reactor_unit[] units = {}, ---@type reactor_unit[]
types = { AUTO_SCRAM = AUTO_SCRAM, START_STATUS = START_STATUS }, types = { AUTO_SCRAM = AUTO_SCRAM, START_STATUS = START_STATUS, RCV_STATE = RCV_STATE },
status_text = { "START UP", "initializing..." }, status_text = { "START UP", "initializing..." },
all_sys_ok = false, all_sys_ok = false,
allow_testing = false, allow_testing = false,
@ -53,7 +64,8 @@ function facility.new(config)
fac_tank_defs = config.FacilityTankDefs, fac_tank_defs = config.FacilityTankDefs,
fac_tank_list = config.FacilityTankList, fac_tank_list = config.FacilityTankList,
fac_tank_conns = config.FacilityTankConns, fac_tank_conns = config.FacilityTankConns,
tank_fluid_types = config.TankFluidTypes tank_fluid_types = config.TankFluidTypes,
aux_coolant = config.AuxiliaryCoolant
}, },
-- rtus -- rtus
rtu_gw_conn_count = 0, rtu_gw_conn_count = 0,
@ -66,12 +78,15 @@ function facility.new(config)
-- redstone I/O control -- redstone I/O control
io_ctl = nil, ---@type rs_controller io_ctl = nil, ---@type rs_controller
-- process control -- process control
recovery = RCV_STATE.INACTIVE, ---@type RECOVERY_STATE
recovery_boot_state = nil, ---@type sv_boot_state|nil
last_unit_states = {}, ---@type boolean[]
units_ready = false, units_ready = false,
mode = PROCESS.INACTIVE, mode = PROCESS.INACTIVE, ---@type PROCESS
last_mode = PROCESS.INACTIVE, last_mode = PROCESS.INACTIVE, ---@type PROCESS
return_mode = PROCESS.INACTIVE, return_mode = PROCESS.INACTIVE, ---@type PROCESS
mode_set = PROCESS.MAX_BURN, mode_set = PROCESS.MAX_BURN, ---@type PROCESS
start_fail = START_STATUS.OK, start_fail = START_STATUS.OK, ---@type START_STATUS
max_burn_combined = 0.0, -- maximum burn rate to clamp at max_burn_combined = 0.0, -- maximum burn rate to clamp at
burn_target = 0.1, -- burn rate target for aggregate burn mode burn_target = 0.1, -- burn rate target for aggregate burn mode
charge_setpoint = 0, -- FE charge target setpoint charge_setpoint = 0, -- FE charge target setpoint
@ -101,8 +116,8 @@ function facility.new(config)
last_error = 0.0, last_error = 0.0,
last_time = 0.0, last_time = 0.0,
-- waste processing -- waste processing
waste_product = WASTE.PLUTONIUM, waste_product = WASTE.PLUTONIUM, ---@type WASTE_PRODUCT
current_waste_product = WASTE.PLUTONIUM, current_waste_product = WASTE.PLUTONIUM, ---@type WASTE_PRODUCT
pu_fallback = false, pu_fallback = false,
sps_low_power = false, sps_low_power = false,
disabled_sps = false, disabled_sps = false,
@ -126,14 +141,16 @@ function facility.new(config)
imtx_faulted_times = { 0, 0, 0 } imtx_faulted_times = { 0, 0, 0 }
} }
--#region SETUP
-- provide self to facility update functions -- provide self to facility update functions
local f_update = fac_update(self) local f_update = fac_update(self)
-- create units -- create units
for i = 1, config.UnitCount do for i = 1, config.UnitCount do
table.insert(self.units, table.insert(self.units, unit.new(i, self.cooling_conf.r_cool[i].BoilerCount, self.cooling_conf.r_cool[i].TurbineCount, config.ExtChargeIdling, self.cooling_conf.aux_coolant[i]))
unit.new(i, self.cooling_conf.r_cool[i].BoilerCount, self.cooling_conf.r_cool[i].TurbineCount, config.ExtChargeIdling))
table.insert(self.group_map, AUTO_GROUP.MANUAL) table.insert(self.group_map, AUTO_GROUP.MANUAL)
table.insert(self.last_unit_states, false)
end end
-- list for RTU session management -- list for RTU session management
@ -149,6 +166,70 @@ function facility.new(config)
table.insert(self.test_tone_states, false) table.insert(self.test_tone_states, false)
end end
-- init next boot state
settings.set("LastProcessState", PROCESS.INACTIVE)
settings.set("LastUnitStates", self.last_unit_states)
if not settings.save("/supervisor.settings") then
log.warning("FAC: failed to save initial control state into supervisor settings file")
end
--#endregion
-- PRIVATE FUNCTIONS --
-- check an auto process control configuration and save it if its valid (does not start the process)
---@param auto_cfg start_auto_config configuration
---@return boolean ready, number[] unit_limits
local function _auto_check_and_save(auto_cfg)
local ready = false
-- load up current limits
local limits = {}
for i = 1, config.UnitCount do
limits[i] = self.units[i].get_control_inf().lim_br100 * 100
end
-- only allow changes if not running
if self.mode == PROCESS.INACTIVE then
if (type(auto_cfg.mode) == "number") and (auto_cfg.mode > PROCESS.INACTIVE) and (auto_cfg.mode <= PROCESS.GEN_RATE) then
self.mode_set = auto_cfg.mode
end
if (type(auto_cfg.burn_target) == "number") and auto_cfg.burn_target >= 0.1 then
self.burn_target = auto_cfg.burn_target
end
if (type(auto_cfg.charge_target) == "number") and auto_cfg.charge_target >= 0 then
self.charge_setpoint = auto_cfg.charge_target * CHARGE_SCALER
end
if (type(auto_cfg.gen_target) == "number") and auto_cfg.gen_target >= 0 then
self.gen_rate_setpoint = auto_cfg.gen_target * GEN_SCALER
end
if (type(auto_cfg.limits) == "table") and (#auto_cfg.limits == config.UnitCount) then
for i = 1, config.UnitCount do
local limit = auto_cfg.limits[i]
if (type(limit) == "number") and (limit >= 0.1) then
limits[i] = limit
self.units[i].set_burn_limit(limit)
end
end
end
ready = self.mode_set > 0
if ((self.mode_set == PROCESS.CHARGE) and (self.charge_setpoint <= 0)) or
((self.mode_set == PROCESS.GEN_RATE) and (self.gen_rate_setpoint <= 0)) or
((self.mode_set == PROCESS.BURN_RATE) and (self.burn_target < 0.1)) then
ready = false
end
end
return ready, limits
end
-- PUBLIC FUNCTIONS -- -- PUBLIC FUNCTIONS --
---@class facility ---@class facility
@ -239,6 +320,9 @@ function facility.new(config)
-- update (iterate) the facility management -- update (iterate) the facility management
function public.update() function public.update()
-- run reboot recovery routine if needed
f_update.boot_recovery()
-- run process control and evaluate automatic SCRAM -- run process control and evaluate automatic SCRAM
f_update.pre_auto() f_update.pre_auto()
f_update.auto_control(config.ExtChargeIdling) f_update.auto_control(config.ExtChargeIdling)
@ -267,6 +351,50 @@ function facility.new(config)
--#endregion --#endregion
--#region Startup Recovery
-- on exit, use this to clear the boot state so we don't resume when exiting cleanly
function public.clear_boot_state()
settings.unset("LastProcessState")
settings.unset("LastUnitStates")
if not settings.save("/supervisor.settings") then
log.warning("facility.clear_boot_state(): failed to save supervisor settings file")
else
log.debug("FAC: cleared boot state on exit")
end
end
-- initialize facility resume boot recovery
---@param state sv_boot_state|nil
function public.boot_recovery_init(state)
if self.recovery == RCV_STATE.INACTIVE and state then
self.recovery_boot_state = state
self.recovery = RCV_STATE.PRIMED
log.info("FAC: startup resume ready")
end
end
-- attempt facility resume boot recovery
---@param auto_cfg start_auto_config configuration
function public.boot_recovery_start(auto_cfg)
if self.recovery == RCV_STATE.PRIMED then
self.recovery = util.trinary(_auto_check_and_save(auto_cfg), RCV_STATE.RUNNING, RCV_STATE.STOPPED)
log.info(util.c("FAC: startup resume ", util.trinary(self.recovery == RCV_STATE.RUNNING, "started", "failed")))
else self.recovery = RCV_STATE.STOPPED end
end
-- used on certain coordinator commands to end reboot recovery (remain in current operational state)
function public.cancel_recovery()
if self.recovery == RCV_STATE.RUNNING then
self.recovery = RCV_STATE.STOPPED
self.recovery_boot_state = nil
log.info("FAC: process startup resume cancelled by user operation")
end
end
--#endregion
--#region Commands --#region Commands
-- SCRAM all reactor units -- SCRAM all reactor units
@ -290,59 +418,13 @@ function facility.new(config)
function public.auto_stop() self.mode = PROCESS.INACTIVE end function public.auto_stop() self.mode = PROCESS.INACTIVE end
-- set automatic control configuration and start the process -- set automatic control configuration and start the process
---@param auto_cfg sys_auto_config configuration ---@param auto_cfg start_auto_config configuration
---@return table response ready state (successfully started) and current configuration (after updating) ---@return table response ready state (successfully started) and current configuration (after updating)
function public.auto_start(auto_cfg) function public.auto_start(auto_cfg)
local charge_scaler = 1000000 -- convert MFE to FE local ready, limits = _auto_check_and_save(auto_cfg)
local gen_scaler = 1000 -- convert kFE to FE
local ready = false
-- load up current limits if ready and self.units_ready then
local limits = {} self.mode = self.mode_set
for i = 1, config.UnitCount do
limits[i] = self.units[i].get_control_inf().lim_br100 * 100
end
-- only allow changes if not running
if self.mode == PROCESS.INACTIVE then
if (type(auto_cfg.mode) == "number") and (auto_cfg.mode > PROCESS.INACTIVE) and (auto_cfg.mode <= PROCESS.GEN_RATE) then
self.mode_set = auto_cfg.mode
end
if (type(auto_cfg.burn_target) == "number") and auto_cfg.burn_target >= 0.1 then
self.burn_target = auto_cfg.burn_target
end
if (type(auto_cfg.charge_target) == "number") and auto_cfg.charge_target >= 0 then
self.charge_setpoint = auto_cfg.charge_target * charge_scaler
end
if (type(auto_cfg.gen_target) == "number") and auto_cfg.gen_target >= 0 then
self.gen_rate_setpoint = auto_cfg.gen_target * gen_scaler
end
if (type(auto_cfg.limits) == "table") and (#auto_cfg.limits == config.UnitCount) then
for i = 1, config.UnitCount do
local limit = auto_cfg.limits[i]
if (type(limit) == "number") and (limit >= 0.1) then
limits[i] = limit
self.units[i].set_burn_limit(limit)
end
end
end
ready = self.mode_set > 0
if ((self.mode_set == PROCESS.CHARGE) and (self.charge_setpoint <= 0)) or
((self.mode_set == PROCESS.GEN_RATE) and (self.gen_rate_setpoint <= 0)) or
((self.mode_set == PROCESS.BURN_RATE) and (self.burn_target < 0.1)) then
ready = false
end
ready = ready and self.units_ready
if ready then self.mode = self.mode_set end
end end
log.debug(util.c("FAC: process start ", util.trinary(ready, "accepted", "rejected"))) log.debug(util.c("FAC: process start ", util.trinary(ready, "accepted", "rejected")))
@ -351,8 +433,8 @@ function facility.new(config)
ready, ready,
self.mode_set, self.mode_set,
self.burn_target, self.burn_target,
self.charge_setpoint / charge_scaler, self.charge_setpoint / CHARGE_SCALER,
self.gen_rate_setpoint / gen_scaler, self.gen_rate_setpoint / GEN_SCALER,
limits limits
} }
end end

View File

@ -5,6 +5,9 @@ local rsio = require("scada-common.rsio")
local types = require("scada-common.types") local types = require("scada-common.types")
local util = require("scada-common.util") local util = require("scada-common.util")
local plc = require("supervisor.session.plc")
local svsessions = require("supervisor.session.svsessions")
local qtypes = require("supervisor.session.rtu.qtypes") local qtypes = require("supervisor.session.rtu.qtypes")
local TONE = audio.TONE local TONE = audio.TONE
@ -12,6 +15,7 @@ local TONE = audio.TONE
local ALARM = types.ALARM local ALARM = types.ALARM
local PRIO = types.ALARM_PRIORITY local PRIO = types.ALARM_PRIORITY
local ALARM_STATE = types.ALARM_STATE local ALARM_STATE = types.ALARM_STATE
local AUTO_GROUP = types.AUTO_GROUP
local CONTAINER_MODE = types.CONTAINER_MODE local CONTAINER_MODE = types.CONTAINER_MODE
local PROCESS = types.PROCESS local PROCESS = types.PROCESS
local PROCESS_NAMES = types.PROCESS_NAMES local PROCESS_NAMES = types.PROCESS_NAMES
@ -131,6 +135,54 @@ end
--#region PUBLIC FUNCTIONS --#region PUBLIC FUNCTIONS
-- run reboot recovery routine if needed
function update.boot_recovery()
local RCV_STATE = self.types.RCV_STATE
-- attempt reboot recovery if in progress
if self.recovery == RCV_STATE.RUNNING then
local was_inactive = self.recovery_boot_state.mode == PROCESS.INACTIVE or self.recovery_boot_state.mode == PROCESS.SYSTEM_ALARM_IDLE
-- try to start auto control
if self.recovery_boot_state.mode ~= nil and self.units_ready then
if not was_inactive then
self.mode = self.mode_set
log.info("FAC: process startup resume initiated")
end
self.recovery_boot_state.mode = nil
end
local recovered = self.recovery_boot_state.mode == nil or was_inactive
-- restore manual control reactors
for i = 1, #self.units do
local u = self.units[i]
if self.recovery_boot_state.unit_states[i] and self.group_map[i] == AUTO_GROUP.MANUAL then
recovered = false
if u.get_control_inf().ready then
local plc_s = svsessions.get_reactor_session(i)
if plc_s ~= nil then
plc_s.in_queue.push_command(plc.PLC_S_CMDS.ENABLE)
log.info("FAC: startup resume enabling manually controlled reactor unit #" .. i)
-- only execute once
self.recovery_boot_state.unit_states[i] = nil
end
end
end
end
if recovered then
self.recovery = RCV_STATE.STOPPED
self.recovery_boot_state = nil
log.info("FAC: startup resume sequence completed")
end
end
end
-- automatic control pre-update logic -- automatic control pre-update logic
function update.pre_auto() function update.pre_auto()
-- unlink RTU sessions if they are closed -- unlink RTU sessions if they are closed
@ -243,6 +295,11 @@ function update.auto_control(ExtChargeIdling)
log.debug(util.c("FAC: state changed from ", PROCESS_NAMES[self.last_mode + 1], " to ", PROCESS_NAMES[self.mode + 1])) log.debug(util.c("FAC: state changed from ", PROCESS_NAMES[self.last_mode + 1], " to ", PROCESS_NAMES[self.mode + 1]))
settings.set("LastProcessState", self.mode)
if not settings.save("/supervisor.settings") then
log.warning("facility_update.auto_control(): failed to save supervisor settings file")
end
if (self.last_mode == PROCESS.INACTIVE) or (self.last_mode == PROCESS.GEN_RATE_FAULT_IDLE) then if (self.last_mode == PROCESS.INACTIVE) or (self.last_mode == PROCESS.GEN_RATE_FAULT_IDLE) then
self.start_fail = START_STATUS.OK self.start_fail = START_STATUS.OK
@ -642,15 +699,16 @@ function update.auto_safety()
self.ascram_reason = AUTO_SCRAM.NONE self.ascram_reason = AUTO_SCRAM.NONE
-- reset PLC RPS trips if we should -- reset PLC RPS trips if we should
for i = 1, #self.units do for i = 1, #self.prio_defs do
local u = self.units[i] for _, u in pairs(self.prio_defs[i]) do
u.auto_cond_rps_reset() u.auto_cond_rps_reset()
end end
end end
end end
end end
end
-- update last mode and set next mode -- update last mode, set next mode, and update saved state as needed
function update.post_auto() function update.post_auto()
self.last_mode = self.mode self.last_mode = self.mode
self.mode = next_mode self.mode = next_mode
@ -792,6 +850,7 @@ end
function update.unit_mgmt() function update.unit_mgmt()
local insufficent_po_rate = false local insufficent_po_rate = false
local need_emcool = false local need_emcool = false
local write_state = false
for i = 1, #self.units do for i = 1, #self.units do
local u = self.units[i] local u = self.units[i]
@ -807,6 +866,21 @@ function update.unit_mgmt()
if (self.cooling_conf.fac_tank_mode > 0) and u.is_emer_cool_tripped() and (self.cooling_conf.fac_tank_defs[i] == 2) then if (self.cooling_conf.fac_tank_mode > 0) and u.is_emer_cool_tripped() and (self.cooling_conf.fac_tank_defs[i] == 2) then
need_emcool = true need_emcool = true
end end
-- check for enabled state changes to save
if self.last_unit_states[i] ~= u.is_reactor_enabled() then
self.last_unit_states[i] = u.is_reactor_enabled()
write_state = true
end
end
-- record unit control states
if write_state then
settings.set("LastUnitStates", self.last_unit_states)
if not settings.save("/supervisor.settings") then
log.warning("facility_update.unit_mgmt(): failed to save supervisor settings file")
end
end end
-- update waste product -- update waste product

View File

@ -25,6 +25,8 @@ local function init(parent, id)
local label_fg = style.fp.label_fg local label_fg = style.fp.label_fg
local term_w, _ = term.getSize()
-- root div -- root div
local root = Div{parent=parent,x=2,y=2,height=4,width=parent.get_width()-2} local root = Div{parent=parent,x=2,y=2,height=4,width=parent.get_width()-2}
local entry = Div{parent=root,x=2,y=1,height=3,fg_bg=style.theme.highlight_box_bright} local entry = Div{parent=root,x=2,y=1,height=3,fg_bg=style.theme.highlight_box_bright}
@ -40,9 +42,9 @@ local function init(parent, id)
local pdg_fw_v = TextBox{parent=entry,x=14,y=2,text=" ------- ",width=20,fg_bg=label_fg} local pdg_fw_v = TextBox{parent=entry,x=14,y=2,text=" ------- ",width=20,fg_bg=label_fg}
pdg_fw_v.register(databus.ps, ps_prefix .. "fw", pdg_fw_v.set_value) pdg_fw_v.register(databus.ps, ps_prefix .. "fw", pdg_fw_v.set_value)
TextBox{parent=entry,x=35,y=2,text="RTT:",width=4} TextBox{parent=entry,x=term_w-16,y=2,text="RTT:",width=4}
local pdg_rtt = DataIndicator{parent=entry,x=40,y=2,label="",unit="",format="%5d",value=0,width=5,fg_bg=label_fg} local pdg_rtt = DataIndicator{parent=entry,x=term_w-11,y=2,label="",unit="",format="%5d",value=0,width=5,fg_bg=label_fg}
TextBox{parent=entry,x=46,y=2,text="ms",width=4,fg_bg=label_fg} TextBox{parent=entry,x=term_w-5,y=2,text="ms",width=4,fg_bg=label_fg}
pdg_rtt.register(databus.ps, ps_prefix .. "rtt", pdg_rtt.update) pdg_rtt.register(databus.ps, ps_prefix .. "rtt", pdg_rtt.update)
pdg_rtt.register(databus.ps, ps_prefix .. "rtt_color", pdg_rtt.recolor) pdg_rtt.register(databus.ps, ps_prefix .. "rtt_color", pdg_rtt.recolor)

View File

@ -25,6 +25,8 @@ local function init(parent, id)
local label_fg = style.fp.label_fg local label_fg = style.fp.label_fg
local term_w, _ = term.getSize()
-- root div -- root div
local root = Div{parent=parent,x=2,y=2,height=4,width=parent.get_width()-2} local root = Div{parent=parent,x=2,y=2,height=4,width=parent.get_width()-2}
local entry = Div{parent=root,x=2,y=1,height=3,fg_bg=style.theme.highlight_box_bright} local entry = Div{parent=root,x=2,y=1,height=3,fg_bg=style.theme.highlight_box_bright}
@ -40,13 +42,13 @@ local function init(parent, id)
local unit_count = DataIndicator{parent=entry,x=17,y=2,label="",unit="",format="%2d",value=0,width=2,fg_bg=style.fp.label_d_fg} local unit_count = DataIndicator{parent=entry,x=17,y=2,label="",unit="",format="%2d",value=0,width=2,fg_bg=style.fp.label_d_fg}
unit_count.register(databus.ps, ps_prefix .. "units", unit_count.set_value) unit_count.register(databus.ps, ps_prefix .. "units", unit_count.set_value)
TextBox{parent=entry,x=21,y=2,text="FW:",width=3} TextBox{parent=entry,x=term_w-30,y=2,text="FW:",width=3}
local rtu_fw_v = TextBox{parent=entry,x=25,y=2,text=" ------- ",width=9,fg_bg=label_fg} local rtu_fw_v = TextBox{parent=entry,x=term_w-26,y=2,text=" ------- ",width=9,fg_bg=label_fg}
rtu_fw_v.register(databus.ps, ps_prefix .. "fw", rtu_fw_v.set_value) rtu_fw_v.register(databus.ps, ps_prefix .. "fw", rtu_fw_v.set_value)
TextBox{parent=entry,x=36,y=2,text="RTT:",width=4} TextBox{parent=entry,x=term_w-15,y=2,text="RTT:",width=4}
local rtu_rtt = DataIndicator{parent=entry,x=40,y=2,label="",unit="",format="%5d",value=0,width=5,fg_bg=label_fg} local rtu_rtt = DataIndicator{parent=entry,x=term_w-11,y=2,label="",unit="",format="%5d",value=0,width=5,fg_bg=label_fg}
TextBox{parent=entry,x=46,y=2,text="ms",width=4,fg_bg=label_fg} TextBox{parent=entry,x=term_w-5,y=2,text="ms",width=4,fg_bg=label_fg}
rtu_rtt.register(databus.ps, ps_prefix .. "rtt", rtu_rtt.update) rtu_rtt.register(databus.ps, ps_prefix .. "rtt", rtu_rtt.update)
rtu_rtt.register(databus.ps, ps_prefix .. "rtt_color", rtu_rtt.recolor) rtu_rtt.register(databus.ps, ps_prefix .. "rtt_color", rtu_rtt.recolor)

View File

@ -41,6 +41,8 @@ local function init(panel)
local label_fg = style.fp.label_fg local label_fg = style.fp.label_fg
local label_d_fg = style.fp.label_d_fg local label_d_fg = style.fp.label_d_fg
local term_w, term_h = term.getSize()
TextBox{parent=panel,y=1,text="SCADA SUPERVISOR",alignment=ALIGN.CENTER,fg_bg=style.theme.header} TextBox{parent=panel,y=1,text="SCADA SUPERVISOR",alignment=ALIGN.CENTER,fg_bg=style.theme.header}
local page_div = Div{parent=panel,x=1,y=3} local page_div = Div{parent=panel,x=1,y=3}
@ -73,9 +75,9 @@ local function init(panel)
-- about footer -- about footer
-- --
local about = Div{parent=main_page,width=15,height=3,x=1,y=16,fg_bg=style.fp.disabled_fg} local about = Div{parent=main_page,width=15,height=2,y=term_h-3,fg_bg=style.fp.disabled_fg}
local fw_v = TextBox{parent=about,x=1,y=1,text="FW: v00.00.00"} local fw_v = TextBox{parent=about,text="FW: v00.00.00"}
local comms_v = TextBox{parent=about,x=1,y=2,text="NT: v00.00.00"} local comms_v = TextBox{parent=about,text="NT: v00.00.00"}
fw_v.register(databus.ps, "version", function (version) fw_v.set_value(util.c("FW: ", version)) end) fw_v.register(databus.ps, "version", function (version) fw_v.set_value(util.c("FW: ", version)) end)
comms_v.register(databus.ps, "comms_version", function (version) comms_v.set_value(util.c("NT: v", version)) end) comms_v.register(databus.ps, "comms_version", function (version) comms_v.set_value(util.c("NT: v", version)) end)
@ -87,7 +89,7 @@ local function init(panel)
-- plc sessions page -- plc sessions page
local plc_page = Div{parent=page_div,x=1,y=1,hidden=true} local plc_page = Div{parent=page_div,x=1,y=1,hidden=true}
local plc_list = Div{parent=plc_page,x=2,y=2,width=49} local plc_list = Div{parent=plc_page,x=2,y=2,width=term_w-2}
for i = 1, supervisor.config.UnitCount do for i = 1, supervisor.config.UnitCount do
local ps_prefix = "plc_" .. i .. "_" local ps_prefix = "plc_" .. i .. "_"
@ -103,13 +105,13 @@ local function init(panel)
local plc_addr = TextBox{parent=plc_entry,x=17,y=2,text=" --- ",width=5,fg_bg=label_d_fg} local plc_addr = TextBox{parent=plc_entry,x=17,y=2,text=" --- ",width=5,fg_bg=label_d_fg}
plc_addr.register(databus.ps, ps_prefix .. "addr", plc_addr.set_value) plc_addr.register(databus.ps, ps_prefix .. "addr", plc_addr.set_value)
TextBox{parent=plc_entry,x=23,y=2,text="FW:",width=3} TextBox{parent=plc_entry,x=term_w-28,y=2,text="FW:",width=3}
local plc_fw_v = TextBox{parent=plc_entry,x=27,y=2,text=" ------- ",width=9,fg_bg=label_fg} local plc_fw_v = TextBox{parent=plc_entry,x=term_w-24,y=2,text=" ------- ",width=9,fg_bg=label_fg}
plc_fw_v.register(databus.ps, ps_prefix .. "fw", plc_fw_v.set_value) plc_fw_v.register(databus.ps, ps_prefix .. "fw", plc_fw_v.set_value)
TextBox{parent=plc_entry,x=37,y=2,text="RTT:",width=4} TextBox{parent=plc_entry,x=term_w-14,y=2,text="RTT:",width=4}
local plc_rtt = DataIndicator{parent=plc_entry,x=42,y=2,label="",unit="",format="%4d",value=0,width=4,fg_bg=label_fg} local plc_rtt = DataIndicator{parent=plc_entry,x=term_w-9,y=2,label="",unit="",format="%4d",value=0,width=4,fg_bg=label_fg}
TextBox{parent=plc_entry,x=47,y=2,text="ms",width=4,fg_bg=label_fg} TextBox{parent=plc_entry,x=term_w-4,y=2,text="ms",width=4,fg_bg=label_fg}
plc_rtt.register(databus.ps, ps_prefix .. "rtt", plc_rtt.update) plc_rtt.register(databus.ps, ps_prefix .. "rtt", plc_rtt.update)
plc_rtt.register(databus.ps, ps_prefix .. "rtt_color", plc_rtt.recolor) plc_rtt.register(databus.ps, ps_prefix .. "rtt_color", plc_rtt.recolor)
@ -119,13 +121,13 @@ local function init(panel)
-- rtu sessions page -- rtu sessions page
local rtu_page = Div{parent=page_div,x=1,y=1,hidden=true} local rtu_page = Div{parent=page_div,x=1,y=1,hidden=true}
local rtu_list = ListBox{parent=rtu_page,x=1,y=1,height=17,width=51,scroll_height=1000,fg_bg=cpair(colors.black,colors.ivory),nav_fg_bg=cpair(colors.gray,colors.lightGray),nav_active=cpair(colors.black,colors.gray)} local rtu_list = ListBox{parent=rtu_page,y=1,height=term_h-2,width=term_w,scroll_height=1000,fg_bg=cpair(colors.black,colors.ivory),nav_fg_bg=cpair(colors.gray,colors.lightGray),nav_active=cpair(colors.black,colors.gray)}
local _ = Div{parent=rtu_list,height=1} -- padding local _ = Div{parent=rtu_list,height=1} -- padding
-- coordinator session page -- coordinator session page
local crd_page = Div{parent=page_div,x=1,y=1,hidden=true} local crd_page = Div{parent=page_div,x=1,y=1,hidden=true}
local crd_box = Div{parent=crd_page,x=2,y=2,width=49,height=4,fg_bg=s_hi_bright} local crd_box = Div{parent=crd_page,x=2,y=2,width=term_w-2,height=4,fg_bg=s_hi_bright}
local crd_conn = LED{parent=crd_box,x=2,y=2,label="CONNECTION",colors=cpair(colors.green_hc,colors.green_off)} local crd_conn = LED{parent=crd_box,x=2,y=2,label="CONNECTION",colors=cpair(colors.green_hc,colors.green_off)}
crd_conn.register(databus.ps, "crd_conn", crd_conn.update) crd_conn.register(databus.ps, "crd_conn", crd_conn.update)
@ -138,27 +140,27 @@ local function init(panel)
local crd_fw_v = TextBox{parent=crd_box,x=26,y=2,text=" ------- ",width=9,fg_bg=label_fg} local crd_fw_v = TextBox{parent=crd_box,x=26,y=2,text=" ------- ",width=9,fg_bg=label_fg}
crd_fw_v.register(databus.ps, "crd_fw", crd_fw_v.set_value) crd_fw_v.register(databus.ps, "crd_fw", crd_fw_v.set_value)
TextBox{parent=crd_box,x=36,y=2,text="RTT:",width=4} TextBox{parent=crd_box,x=term_w-15,y=2,text="RTT:",width=4}
local crd_rtt = DataIndicator{parent=crd_box,x=41,y=2,label="",unit="",format="%5d",value=0,width=5,fg_bg=label_fg} local crd_rtt = DataIndicator{parent=crd_box,x=term_w-10,y=2,label="",unit="",format="%5d",value=0,width=5,fg_bg=label_fg}
TextBox{parent=crd_box,x=47,y=2,text="ms",width=4,fg_bg=label_fg} TextBox{parent=crd_box,x=term_w-4,y=2,text="ms",width=4,fg_bg=label_fg}
crd_rtt.register(databus.ps, "crd_rtt", crd_rtt.update) crd_rtt.register(databus.ps, "crd_rtt", crd_rtt.update)
crd_rtt.register(databus.ps, "crd_rtt_color", crd_rtt.recolor) crd_rtt.register(databus.ps, "crd_rtt_color", crd_rtt.recolor)
-- pocket sessions page -- pocket sessions page
local pkt_page = Div{parent=page_div,x=1,y=1,hidden=true} local pkt_page = Div{parent=page_div,y=1,hidden=true}
local pdg_list = ListBox{parent=pkt_page,x=1,y=1,height=17,width=51,scroll_height=1000,fg_bg=style.fp.text_fg,nav_fg_bg=cpair(colors.gray,colors.lightGray),nav_active=cpair(colors.black,colors.gray)} local pdg_list = ListBox{parent=pkt_page,y=1,height=term_h-2,width=term_w,scroll_height=1000,fg_bg=style.fp.text_fg,nav_fg_bg=cpair(colors.gray,colors.lightGray),nav_active=cpair(colors.black,colors.gray)}
local _ = Div{parent=pdg_list,height=1} -- padding local _ = Div{parent=pdg_list,height=1} -- padding
-- RTU device ID check/diagnostics page -- RTU device ID check/diagnostics page
local chk_page = Div{parent=page_div,x=1,y=1,hidden=true} local chk_page = Div{parent=page_div,y=1,hidden=true}
local chk_list = ListBox{parent=chk_page,x=1,y=1,height=17,width=51,scroll_height=1000,fg_bg=style.fp.text_fg,nav_fg_bg=cpair(colors.gray,colors.lightGray),nav_active=cpair(colors.black,colors.gray)} local chk_list = ListBox{parent=chk_page,y=1,height=term_h-2,width=term_w,scroll_height=1000,fg_bg=style.fp.text_fg,nav_fg_bg=cpair(colors.gray,colors.lightGray),nav_active=cpair(colors.black,colors.gray)}
local _ = Div{parent=chk_list,height=1} -- padding local _ = Div{parent=chk_list,height=1} -- padding
-- info page -- info page
local info_page = Div{parent=page_div,x=1,y=1,hidden=true} local info_page = Div{parent=page_div,y=1,hidden=true}
local info = Div{parent=info_page,height=6,x=2,y=2} local info = Div{parent=info_page,height=6,x=2,y=2}
TextBox{parent=info,text="SVR \x1a Supervisor Status"} TextBox{parent=info,text="SVR \x1a Supervisor Status"}
@ -168,7 +170,7 @@ local function init(panel)
TextBox{parent=info,text="PKT \x1a Pocket Connections"} TextBox{parent=info,text="PKT \x1a Pocket Connections"}
TextBox{parent=info,text="DEV \x1a RTU Device/Configuration Alerts"} TextBox{parent=info,text="DEV \x1a RTU Device/Configuration Alerts"}
local notes = Div{parent=info_page,width=49,height=8,x=2,y=9,fg_bg=style.fp.disabled_fg} local notes = Div{parent=info_page,width=term_w-2,height=8,x=2,y=9,fg_bg=style.fp.disabled_fg}
TextBox{parent=notes,text="The DEV tab will show missing devices and devices that connected with incorrect information. Missing entries will indicate how the configuration should be, duplicate entries will indicate what is a duplicate, and out-of-range entries will indicate the invalid entry. An out-of-range example is a #2 turbine when you should only have 1 turbine for that unit."} TextBox{parent=notes,text="The DEV tab will show missing devices and devices that connected with incorrect information. Missing entries will indicate how the configuration should be, duplicate entries will indicate what is a duplicate, and out-of-range entries will indicate the invalid entry. An out-of-range example is a #2 turbine when you should only have 1 turbine for that unit."}

View File

@ -234,6 +234,23 @@ function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, tim
if pkt.type == CRDN_TYPE.INITIAL_BUILDS then if pkt.type == CRDN_TYPE.INITIAL_BUILDS then
-- acknowledgement to coordinator receiving builds -- acknowledgement to coordinator receiving builds
self.acks.builds = true self.acks.builds = true
elseif pkt.type == CRDN_TYPE.PROCESS_READY then
if pkt.length == 5 then
-- coordinator has sent all initial process data, power-on recovery is now possible
---@type start_auto_config
local config = {
mode = pkt.data[1],
burn_target = pkt.data[2],
charge_target = pkt.data[3],
gen_target = pkt.data[4],
limits = pkt.data[5]
}
facility.boot_recovery_start(config)
else
log.debug(log_tag .. "CRDN process ready packet length mismatch")
end
elseif pkt.type == CRDN_TYPE.FAC_BUILDS then elseif pkt.type == CRDN_TYPE.FAC_BUILDS then
-- acknowledgement to coordinator receiving builds -- acknowledgement to coordinator receiving builds
self.acks.fac_builds = true self.acks.fac_builds = true
@ -243,8 +260,11 @@ function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, tim
if cmd == FAC_COMMAND.SCRAM_ALL then if cmd == FAC_COMMAND.SCRAM_ALL then
facility.scram_all() facility.scram_all()
facility.cancel_recovery()
_send(CRDN_TYPE.FAC_CMD, { cmd, true }) _send(CRDN_TYPE.FAC_CMD, { cmd, true })
elseif cmd == FAC_COMMAND.STOP then elseif cmd == FAC_COMMAND.STOP then
facility.cancel_recovery()
local was_active = facility.auto_is_active() local was_active = facility.auto_is_active()
if was_active then if was_active then
@ -253,15 +273,16 @@ function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, tim
_send(CRDN_TYPE.FAC_CMD, { cmd, was_active }) _send(CRDN_TYPE.FAC_CMD, { cmd, was_active })
elseif cmd == FAC_COMMAND.START then elseif cmd == FAC_COMMAND.START then
facility.cancel_recovery()
if pkt.length == 6 then if pkt.length == 6 then
---@type sys_auto_config ---@class start_auto_config
---@diagnostic disable-next-line: missing-fields
local config = { local config = {
mode = pkt.data[2], mode = pkt.data[2], ---@type PROCESS
burn_target = pkt.data[3], burn_target = pkt.data[3], ---@type number
charge_target = pkt.data[4], charge_target = pkt.data[4], ---@type number
gen_target = pkt.data[5], gen_target = pkt.data[5], ---@type number
limits = pkt.data[6] limits = pkt.data[6] ---@type number[]
} }
_send(CRDN_TYPE.FAC_CMD, { cmd, table.unpack(facility.auto_start(config)) }) _send(CRDN_TYPE.FAC_CMD, { cmd, table.unpack(facility.auto_start(config)) })
@ -313,8 +334,11 @@ function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, tim
local manual = facility.get_group(uid) == AUTO_GROUP.MANUAL local manual = facility.get_group(uid) == AUTO_GROUP.MANUAL
if cmd == UNIT_COMMAND.SCRAM then if cmd == UNIT_COMMAND.SCRAM then
facility.cancel_recovery()
out_queue.push_data(SV_Q_DATA.SCRAM, data) out_queue.push_data(SV_Q_DATA.SCRAM, data)
elseif cmd == UNIT_COMMAND.START then elseif cmd == UNIT_COMMAND.START then
facility.cancel_recovery()
if manual then if manual then
out_queue.push_data(SV_Q_DATA.START, data) out_queue.push_data(SV_Q_DATA.START, data)
else else
@ -324,6 +348,8 @@ function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, tim
elseif cmd == UNIT_COMMAND.RESET_RPS then elseif cmd == UNIT_COMMAND.RESET_RPS then
out_queue.push_data(SV_Q_DATA.RESET_RPS, data) out_queue.push_data(SV_Q_DATA.RESET_RPS, data)
elseif cmd == UNIT_COMMAND.SET_BURN then elseif cmd == UNIT_COMMAND.SET_BURN then
facility.cancel_recovery()
if pkt.length == 3 then if pkt.length == 3 then
if manual then if manual then
out_queue.push_data(SV_Q_DATA.SET_BURN, data) out_queue.push_data(SV_Q_DATA.SET_BURN, data)
@ -354,6 +380,8 @@ function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, tim
log.debug(log_tag .. "CRDN unit command reset alarm missing alarm id") log.debug(log_tag .. "CRDN unit command reset alarm missing alarm id")
end end
elseif cmd == UNIT_COMMAND.SET_GROUP then elseif cmd == UNIT_COMMAND.SET_GROUP then
facility.cancel_recovery()
if (pkt.length == 3) and (type(pkt.data[3]) == "number") and if (pkt.length == 3) and (type(pkt.data[3]) == "number") and
(pkt.data[3] >= AUTO_GROUP.MANUAL) and (pkt.data[3] <= AUTO_GROUP.BACKUP) then (pkt.data[3] >= AUTO_GROUP.MANUAL) and (pkt.data[3] <= AUTO_GROUP.BACKUP) then
facility.set_group(unit.get_id(), pkt.data[3]) facility.set_group(unit.get_id(), pkt.data[3])

View File

@ -53,15 +53,15 @@ local PERIODICS = {
---@param in_queue mqueue in message queue ---@param in_queue mqueue in message queue
---@param out_queue mqueue out message queue ---@param out_queue mqueue out message queue
---@param timeout number communications timeout ---@param timeout number communications timeout
---@param initial_reset boolean[] initial PLC reset on timeout flags, indexed by reactor_id
---@param fp_ok boolean if the front panel UI is running ---@param fp_ok boolean if the front panel UI is running
function plc.new_session(id, s_addr, i_seq_num, reactor_id, in_queue, out_queue, timeout, fp_ok) function plc.new_session(id, s_addr, i_seq_num, reactor_id, in_queue, out_queue, timeout, initial_reset, fp_ok)
-- print a log message to the terminal as long as the UI isn't running -- print a log message to the terminal as long as the UI isn't running
local function println(message) if not fp_ok then util.println_ts(message) end end local function println(message) if not fp_ok then util.println_ts(message) end end
local log_tag = "plc_session(" .. id .. "): " local log_tag = "plc_session(" .. id .. "): "
local self = { local self = {
commanded_state = false,
commanded_burn_rate = 0.0, commanded_burn_rate = 0.0,
auto_cmd_token = 0, auto_cmd_token = 0,
ramping_rate = false, ramping_rate = false,
@ -72,6 +72,7 @@ function plc.new_session(id, s_addr, i_seq_num, reactor_id, in_queue, out_queue,
connected = true, connected = true,
received_struct = false, received_struct = false,
received_status_cache = false, received_status_cache = false,
received_rps_status = false,
conn_watchdog = util.new_watchdog(timeout), conn_watchdog = util.new_watchdog(timeout),
last_rtt = 0, last_rtt = 0,
-- periodic messages -- periodic messages
@ -381,6 +382,16 @@ function plc.new_session(id, s_addr, i_seq_num, reactor_id, in_queue, out_queue,
local status = pcall(_copy_rps_status, pkt.data) local status = pcall(_copy_rps_status, pkt.data)
if status then if status then
-- copied in RPS status data OK -- copied in RPS status data OK
self.received_rps_status = true
-- try initial reset if needed
if initial_reset[reactor_id] then
initial_reset[reactor_id] = false
if self.sDB.rps_trip_cause == "timeout" then
_send(RPLC_TYPE.RPS_AUTO_RESET, {})
log.debug(log_tag .. "initial RPS reset on timeout status sent")
end
end
else else
-- error copying RPS status data -- error copying RPS status data
log.error(log_tag .. "failed to parse RPS status packet data") log.error(log_tag .. "failed to parse RPS status packet data")
@ -394,6 +405,16 @@ function plc.new_session(id, s_addr, i_seq_num, reactor_id, in_queue, out_queue,
local status = pcall(_copy_rps_status, { true, table.unpack(pkt.data) }) local status = pcall(_copy_rps_status, { true, table.unpack(pkt.data) })
if status then if status then
-- copied in RPS status data OK -- copied in RPS status data OK
self.received_rps_status = true
-- try initial reset if needed
if initial_reset[reactor_id] then
initial_reset[reactor_id] = false
if self.sDB.rps_trip_cause == "timeout" then
_send(RPLC_TYPE.RPS_AUTO_RESET, {})
log.debug(log_tag .. "initial RPS reset on timeout alarm sent")
end
end
else else
-- error copying RPS status data -- error copying RPS status data
log.error(log_tag .. "failed to parse RPS alarm status data") log.error(log_tag .. "failed to parse RPS alarm status data")
@ -487,6 +508,10 @@ function plc.new_session(id, s_addr, i_seq_num, reactor_id, in_queue, out_queue,
---@nodiscard ---@nodiscard
function public.get_db() return self.sDB end function public.get_db() return self.sDB end
-- check if the reactor structure, status, and RPS status have been received
---@nodiscard
function public.check_received_all_data() return self.received_struct and self.received_status_cache and self.received_rps_status end
-- check if ramping is completed by first verifying auto command token ack -- check if ramping is completed by first verifying auto command token ack
---@nodiscard ---@nodiscard
function public.is_ramp_complete() function public.is_ramp_complete()

View File

@ -45,6 +45,7 @@ local self = {
fp_ok = false, fp_ok = false,
config = nil, ---@type svr_config config = nil, ---@type svr_config
facility = nil, ---@type facility|nil facility = nil, ---@type facility|nil
plc_ini_reset = {},
-- lists of connected sessions -- lists of connected sessions
---@diagnostic disable: missing-fields ---@diagnostic disable: missing-fields
sessions = { sessions = {
@ -391,6 +392,7 @@ function svsessions.init(nic, fp_ok, config, facility)
conns.tanks[1] = true conns.tanks[1] = true
end end
self.plc_ini_reset[i] = true
self.dev_dbg.connected.units[i] = conns self.dev_dbg.connected.units[i] = conns
end end
end end
@ -486,7 +488,7 @@ function svsessions.establish_plc_session(source_addr, i_seq_num, for_reactor, v
local id = self.next_ids.plc local id = self.next_ids.plc
plc_s.instance = plc.new_session(id, source_addr, i_seq_num, for_reactor, plc_s.in_queue, plc_s.out_queue, self.config.PLC_Timeout, self.fp_ok) plc_s.instance = plc.new_session(id, source_addr, i_seq_num, for_reactor, plc_s.in_queue, plc_s.out_queue, self.config.PLC_Timeout, self.plc_ini_reset, self.fp_ok)
table.insert(self.sessions.plc, plc_s) table.insert(self.sessions.plc, plc_s)
local units = self.facility.get_units() local units = self.facility.get_units()

View File

@ -10,6 +10,7 @@ local log = require("scada-common.log")
local network = require("scada-common.network") local network = require("scada-common.network")
local ppm = require("scada-common.ppm") local ppm = require("scada-common.ppm")
local tcd = require("scada-common.tcd") local tcd = require("scada-common.tcd")
local types = require("scada-common.types")
local util = require("scada-common.util") local util = require("scada-common.util")
local core = require("graphics.core") local core = require("graphics.core")
@ -22,7 +23,7 @@ local supervisor = require("supervisor.supervisor")
local svsessions = require("supervisor.session.svsessions") local svsessions = require("supervisor.session.svsessions")
local SUPERVISOR_VERSION = "v1.6.2" local SUPERVISOR_VERSION = "v1.6.8"
local println = util.println local println = util.println
local println_ts = util.println_ts local println_ts = util.println_ts
@ -72,6 +73,21 @@ if config.FacilityTankMode > 0 then
cfv.assert_type_int(def) cfv.assert_type_int(def)
cfv.assert_range(def, 0, 2) cfv.assert_range(def, 0, 2)
assert(cfv.valid(), "startup> invalid facility tank definition for reactor unit " .. i) assert(cfv.valid(), "startup> invalid facility tank definition for reactor unit " .. i)
local entry = config.FacilityTankList[i]
cfv.assert_type_int(entry)
cfv.assert_range(entry, 0, 2)
assert(cfv.valid(), "startup> invalid facility tank list entry for tank " .. i)
local conn = config.FacilityTankConns[i]
cfv.assert_type_int(conn)
cfv.assert_range(conn, 0, #config.FacilityTankDefs)
assert(cfv.valid(), "startup> invalid facility tank connection for reactor unit " .. i)
local type = config.TankFluidTypes[i]
cfv.assert_type_int(type)
cfv.assert_range(type, 0, types.COOLANT_TYPE.SODIUM)
assert(cfv.valid(), "startup> invalid tank fluid type for tank " .. i)
end end
end end
@ -147,6 +163,9 @@ local function main()
-- halve the rate heartbeat LED flash -- halve the rate heartbeat LED flash
local heartbeat_toggle = true local heartbeat_toggle = true
-- init startup recovery
sv_facility.boot_recovery_init(supervisor.boot_state)
-- event loop -- event loop
while true do while true do
local event, param1, param2, param3, param4, param5 = util.pull_event() local event, param1, param2, param3, param4, param5 = util.pull_event()
@ -237,6 +256,8 @@ local function main()
end end
end end
sv_facility.clear_boot_state()
renderer.close_ui() renderer.close_ui()
util.println_ts("exited") util.println_ts("exited")

View File

@ -19,10 +19,24 @@ local config = {}
supervisor.config = config supervisor.config = config
-- load the supervisor configuration -- control state from last unexpected shutdown
supervisor.boot_state = nil ---@type sv_boot_state|nil
-- load the supervisor configuration and startup state
function supervisor.load_config() function supervisor.load_config()
if not settings.load("/supervisor.settings") then return false end if not settings.load("/supervisor.settings") then return false end
---@class sv_boot_state
local boot_state = {
mode = settings.get("LastProcessState"), ---@type PROCESS
unit_states = settings.get("LastUnitStates") ---@type boolean[]
}
-- only record boot state if likely valid
if type(boot_state.mode) == "number" and type(boot_state.unit_states) == "table" then
supervisor.boot_state = boot_state
end
config.UnitCount = settings.get("UnitCount") config.UnitCount = settings.get("UnitCount")
config.CoolingConfig = settings.get("CoolingConfig") config.CoolingConfig = settings.get("CoolingConfig")
config.FacilityTankMode = settings.get("FacilityTankMode") config.FacilityTankMode = settings.get("FacilityTankMode")
@ -30,6 +44,7 @@ function supervisor.load_config()
config.FacilityTankList = settings.get("FacilityTankList") config.FacilityTankList = settings.get("FacilityTankList")
config.FacilityTankConns = settings.get("FacilityTankConns") config.FacilityTankConns = settings.get("FacilityTankConns")
config.TankFluidTypes = settings.get("TankFluidTypes") config.TankFluidTypes = settings.get("TankFluidTypes")
config.AuxiliaryCoolant = settings.get("AuxiliaryCoolant")
config.ExtChargeIdling = settings.get("ExtChargeIdling") config.ExtChargeIdling = settings.get("ExtChargeIdling")
config.SVR_Channel = settings.get("SVR_Channel") config.SVR_Channel = settings.get("SVR_Channel")
@ -64,6 +79,7 @@ function supervisor.load_config()
cfv.assert_type_table(config.FacilityTankList) cfv.assert_type_table(config.FacilityTankList)
cfv.assert_type_table(config.FacilityTankConns) cfv.assert_type_table(config.FacilityTankConns)
cfv.assert_type_table(config.TankFluidTypes) cfv.assert_type_table(config.TankFluidTypes)
cfv.assert_type_table(config.AuxiliaryCoolant)
cfv.assert_range(config.FacilityTankMode, 0, 8) cfv.assert_range(config.FacilityTankMode, 0, 8)
cfv.assert_type_bool(config.ExtChargeIdling) cfv.assert_type_bool(config.ExtChargeIdling)
@ -246,6 +262,17 @@ function supervisor.comms(_version, nic, fp_ok, facility)
-- PLC linking request -- PLC linking request
if packet.length == 4 and type(packet.data[4]) == "number" then if packet.length == 4 and type(packet.data[4]) == "number" then
local reactor_id = packet.data[4] local reactor_id = packet.data[4]
-- check ID validity
if reactor_id < 1 or reactor_id > config.UnitCount then
-- reactor index out of range
if last_ack ~= ESTABLISH_ACK.DENY then
log.warning(util.c("PLC_ESTABLISH: denied assignment ", reactor_id, " outside of configured unit count ", config.UnitCount))
end
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
else
-- try to establish the session
local plc_id = svsessions.establish_plc_session(src_addr, i_seq_num, reactor_id, firmware_v) local plc_id = svsessions.establish_plc_session(src_addr, i_seq_num, reactor_id, firmware_v)
if plc_id == false then if plc_id == false then
@ -261,6 +288,7 @@ function supervisor.comms(_version, nic, fp_ok, facility)
log.info(util.c("PLC_ESTABLISH: PLC (", firmware_v, ") [@", src_addr, "] reactor unit ", reactor_id, " PLC connected with session ID ", plc_id)) log.info(util.c("PLC_ESTABLISH: PLC (", firmware_v, ") [@", src_addr, "] reactor unit ", reactor_id, " PLC connected with session ID ", plc_id))
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW) _send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
end end
end
else else
log.debug("PLC_ESTABLISH: packet length mismatch/bad parameter type") log.debug("PLC_ESTABLISH: packet length mismatch/bad parameter type")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY) _send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)

View File

@ -66,7 +66,8 @@ local unit = {}
---@param num_boilers integer number of boilers expected ---@param num_boilers integer number of boilers expected
---@param num_turbines integer number of turbines expected ---@param num_turbines integer number of turbines expected
---@param ext_idle boolean extended idling mode ---@param ext_idle boolean extended idling mode
function unit.new(reactor_id, num_boilers, num_turbines, ext_idle) ---@param aux_coolant boolean if this unit has auxiliary coolant
function unit.new(reactor_id, num_boilers, num_turbines, ext_idle, aux_coolant)
-- time (ms) to idle for auto idling -- time (ms) to idle for auto idling
local IDLE_TIME = util.trinary(ext_idle, 60000, 10000) local IDLE_TIME = util.trinary(ext_idle, 60000, 10000)
@ -79,6 +80,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
plc_i = nil, ---@type plc_session plc_i = nil, ---@type plc_session
num_boilers = num_boilers, num_boilers = num_boilers,
num_turbines = num_turbines, num_turbines = num_turbines,
aux_coolant = aux_coolant,
types = { DT_KEYS = DT_KEYS, AISTATE = AISTATE }, types = { DT_KEYS = DT_KEYS, AISTATE = AISTATE },
-- rtus -- rtus
rtu_list = {}, ---@type unit_session[][] rtu_list = {}, ---@type unit_session[][]
@ -92,7 +94,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
io_ctl = nil, ---@type rs_controller io_ctl = nil, ---@type rs_controller
---@diagnostic disable-next-line: missing-fields ---@diagnostic disable-next-line: missing-fields
valves = {}, ---@type unit_valves valves = {}, ---@type unit_valves
emcool_opened = false, em_cool_opened = false,
aux_cool_opened = false,
-- auto control -- auto control
auto_engaged = false, auto_engaged = false,
auto_idle = false, auto_idle = false,
@ -111,6 +114,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
damage_est_last = 0, damage_est_last = 0,
waste_product = WASTE.PLUTONIUM, ---@type WASTE_PRODUCT waste_product = WASTE.PLUTONIUM, ---@type WASTE_PRODUCT
status_text = { "UNKNOWN", "awaiting connection..." }, status_text = { "UNKNOWN", "awaiting connection..." },
enable_aux_cool = false,
-- logic for alarms -- logic for alarms
had_reactor = false, had_reactor = false,
turbine_flow_stable = false, turbine_flow_stable = false,
@ -373,6 +377,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
local waste_po = _make_valve_iface(IO.WASTE_POPL) local waste_po = _make_valve_iface(IO.WASTE_POPL)
local waste_sps = _make_valve_iface(IO.WASTE_AM) local waste_sps = _make_valve_iface(IO.WASTE_AM)
local emer_cool = _make_valve_iface(IO.U_EMER_COOL) local emer_cool = _make_valve_iface(IO.U_EMER_COOL)
local aux_cool = _make_valve_iface(IO.U_AUX_COOL)
---@class unit_valves ---@class unit_valves
self.valves = { self.valves = {
@ -380,7 +385,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
waste_sna = waste_sna, waste_sna = waste_sna,
waste_po = waste_po, waste_po = waste_po,
waste_sps = waste_sps, waste_sps = waste_sps,
emer_cool = emer_cool emer_cool = emer_cool,
aux_cool = aux_cool
} }
-- route reactor waste for a given waste product -- route reactor waste for a given waste product
@ -606,7 +612,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
if #self.redstone > 0 then if #self.redstone > 0 then
logic.handle_redstone(self) logic.handle_redstone(self)
elseif not self.plc_cache.rps_trip then elseif not self.plc_cache.rps_trip then
self.emcool_opened = false self.em_cool_opened = false
end end
end end
@ -724,7 +730,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
-- queue a command to clear timeout/auto-scram if set -- queue a command to clear timeout/auto-scram if set
function public.auto_cond_rps_reset() function public.auto_cond_rps_reset()
if self.plc_s ~= nil and self.plc_i ~= nil and (not self.auto_was_alarmed) and (not self.emcool_opened) then if self.plc_s ~= nil and self.plc_i ~= nil and (not self.auto_was_alarmed) and (not self.em_cool_opened) then
local rps = self.plc_i.get_rps() local rps = self.plc_i.get_rps()
if rps.timeout or rps.automatic then if rps.timeout or rps.automatic then
self.plc_i.auto_lock(true) -- if it timed out/restarted, auto lock was lost, so re-lock it self.plc_i.auto_lock(true) -- if it timed out/restarted, auto lock was lost, so re-lock it
@ -840,6 +846,12 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
return false return false
end end
-- check the active state of the reactor (if connected)
---@nodiscard
function public.is_reactor_enabled()
if self.plc_i ~= nil then return self.plc_i.get_status().status else return false end
end
-- check if the reactor is connected, is stopped, the RPS is not tripped, and no alarms are active -- check if the reactor is connected, is stopped, the RPS is not tripped, and no alarms are active
---@nodiscard ---@nodiscard
function public.is_safe_idle() function public.is_safe_idle()
@ -859,7 +871,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
-- check if emergency coolant activation has been tripped -- check if emergency coolant activation has been tripped
---@nodiscard ---@nodiscard
function public.is_emer_cool_tripped() return self.emcool_opened end function public.is_emer_cool_tripped() return self.em_cool_opened end
-- get build properties of machines -- get build properties of machines
-- --
@ -1053,7 +1065,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
v.waste_sna.check(), v.waste_sna.check(),
v.waste_po.check(), v.waste_po.check(),
v.waste_sps.check(), v.waste_sps.check(),
v.emer_cool.check() v.emer_cool.check(),
v.aux_cool.check()
} }
end end

View File

@ -35,6 +35,7 @@ local FLOW_STABILITY_DELAY_MS = const.FLOW_STABILITY_DELAY_MS
local ANNUNC_LIMS = const.ANNUNCIATOR_LIMITS local ANNUNC_LIMS = const.ANNUNCIATOR_LIMITS
local ALARM_LIMS = const.ALARM_LIMITS local ALARM_LIMS = const.ALARM_LIMITS
local RS_THRESH = const.RS_THRESHOLDS
---@class unit_logic_extension ---@class unit_logic_extension
local logic = {} local logic = {}
@ -54,6 +55,10 @@ function logic.update_annunciator(self)
-- variables for boiler, or reactor if no boilers used -- variables for boiler, or reactor if no boilers used
local total_boil_rate = 0.0 local total_boil_rate = 0.0
-- auxiliary coolant control
local need_aux_cool = false
local dis_aux_cool = true
--#region Reactor --#region Reactor
annunc.AutoControl = self.auto_engaged annunc.AutoControl = self.auto_engaged
@ -67,11 +72,10 @@ function logic.update_annunciator(self)
local plc_db = self.plc_i.get_db() local plc_db = self.plc_i.get_db()
-- update ready state -- update ready state
-- - can't be tripped -- - must be connected to a formed reactor
-- - must have received status at least once -- - can't have a tripped RPS
-- - must have received struct at least once -- - must have received status, struct, and RPS status at least once
plc_ready = plc_db.formed and (not plc_db.no_reactor) and (not plc_db.rps_tripped) and plc_ready = plc_db.formed and (not plc_db.no_reactor) and (not plc_db.rps_tripped) and self.plc_i.check_received_all_data()
(next(self.plc_i.get_status()) ~= nil) and (next(self.plc_i.get_struct()) ~= nil)
-- update auto control limit -- update auto control limit
if (plc_db.mek_struct.max_burn > 0) and ((self.db.control.lim_br100 / 100) > plc_db.mek_struct.max_burn) then if (plc_db.mek_struct.max_burn > 0) and ((self.db.control.lim_br100 / 100) > plc_db.mek_struct.max_burn) then
@ -149,6 +153,9 @@ function logic.update_annunciator(self)
-- if no boilers, use reactor heating rate to check for boil rate mismatch -- if no boilers, use reactor heating rate to check for boil rate mismatch
if num_boilers == 0 then if num_boilers == 0 then
total_boil_rate = plc_db.mek_status.heating_rate total_boil_rate = plc_db.mek_status.heating_rate
need_aux_cool = plc_db.mek_status.ccool_fill <= RS_THRESH.AUX_COOL_ENABLE
dis_aux_cool = plc_db.mek_status.ccool_fill >= RS_THRESH.AUX_COOL_DISABLE
end end
else else
self.plc_cache.ok = false self.plc_cache.ok = false
@ -216,6 +223,9 @@ function logic.update_annunciator(self)
annunc.BoilerOnline[idx] = true annunc.BoilerOnline[idx] = true
annunc.WaterLevelLow[idx] = boiler.tanks.water_fill < ANNUNC_LIMS.WaterLevelLow annunc.WaterLevelLow[idx] = boiler.tanks.water_fill < ANNUNC_LIMS.WaterLevelLow
need_aux_cool = need_aux_cool or (boiler.tanks.water_fill <= RS_THRESH.AUX_COOL_ENABLE)
dis_aux_cool = dis_aux_cool and (boiler.tanks.water_fill >= RS_THRESH.AUX_COOL_DISABLE)
end end
-- check heating rate low -- check heating rate low
@ -342,11 +352,11 @@ function logic.update_annunciator(self)
end end
if rotation_stable then if rotation_stable then
log.debug(util.c("UNIT ", self.r_id, ": turbine ", idx, " reached rotational stability (", rotation, ")")) log.debug(util.c("UNIT ", self.r_id, " turbine ", idx, " reached rotational stability (", rotation, ")"))
end end
if flow_stable then if flow_stable then
log.debug(util.c("UNIT ", self.r_id, ": turbine ", idx, " reached flow stability (", turbine.state.flow_rate, " mB/t)")) log.debug(util.c("UNIT ", self.r_id, " turbine ", idx, " reached flow stability (", turbine.state.flow_rate, " mB/t)"))
end end
turbines_stable = turbines_stable and (rotation_stable or flow_stable) turbines_stable = turbines_stable and (rotation_stable or flow_stable)
@ -358,7 +368,7 @@ function logic.update_annunciator(self)
turbines_stable = false turbines_stable = false
log.debug(util.c("UNIT ", self.r_id, ": turbine ", idx, " reset stability (new rate ", turbine.state.steam_input_rate, " != ", last.input_rate," mB/t)")) log.debug(util.c("UNIT ", self.r_id, " turbine ", idx, " reset stability (new rate ", turbine.state.steam_input_rate, " != ", last.input_rate," mB/t)"))
end end
last.input_rate = turbine.state.steam_input_rate last.input_rate = turbine.state.steam_input_rate
@ -407,6 +417,12 @@ function logic.update_annunciator(self)
-- update auto control ready state for this unit -- update auto control ready state for this unit
self.db.control.ready = plc_ready and boilers_ready and turbines_ready self.db.control.ready = plc_ready and boilers_ready and turbines_ready
-- update auxiliary coolant command
if plc_ready then
self.enable_aux_cool = self.plc_i.get_db().mek_status.status and
(self.enable_aux_cool or need_aux_cool) and not (dis_aux_cool and self.turbine_flow_stable)
else self.enable_aux_cool = false end
end end
-- update an alarm state given conditions -- update an alarm state given conditions
@ -729,7 +745,7 @@ function logic.update_status_text(self)
self.status_text = { "RCS TRANSIENT", "check coolant system" } self.status_text = { "RCS TRANSIENT", "check coolant system" }
-- elseif is_active(self.alarms.RPSTransient) then -- elseif is_active(self.alarms.RPSTransient) then
-- RPS status handled when checking reactor status -- RPS status handled when checking reactor status
elseif self.emcool_opened then elseif self.em_cool_opened then
self.status_text = { "EMERGENCY COOLANT OPENED", "reset RPS to close valve" } self.status_text = { "EMERGENCY COOLANT OPENED", "reset RPS to close valve" }
-- connection dependent states -- connection dependent states
elseif self.plc_i ~= nil then elseif self.plc_i ~= nil then
@ -887,7 +903,7 @@ function logic.handle_redstone(self)
(annunc.CoolantLevelLow or (boiler_water_low and rps.ex_hcool)) and (annunc.CoolantLevelLow or (boiler_water_low and rps.ex_hcool)) and
is_active(self.alarms.ReactorOverTemp)) is_active(self.alarms.ReactorOverTemp))
if enable_emer_cool and not self.emcool_opened then if enable_emer_cool and not self.em_cool_opened then
log.debug(util.c(">> Emergency Coolant Enable Detail Report (Unit ", self.r_id, ") <<")) log.debug(util.c(">> Emergency Coolant Enable Detail Report (Unit ", self.r_id, ") <<"))
log.debug(util.c("| CoolantLevelLow[", annunc.CoolantLevelLow, "] CoolantLevelLowLow[", rps.low_cool, "] ExcessHeatedCoolant[", rps.ex_hcool, "]")) log.debug(util.c("| CoolantLevelLow[", annunc.CoolantLevelLow, "] CoolantLevelLowLow[", rps.low_cool, "] ExcessHeatedCoolant[", rps.ex_hcool, "]"))
log.debug(util.c("| ReactorOverTemp[", AISTATE_NAMES[self.alarms.ReactorOverTemp.state], "]")) log.debug(util.c("| ReactorOverTemp[", AISTATE_NAMES[self.alarms.ReactorOverTemp.state], "]"))
@ -911,13 +927,13 @@ function logic.handle_redstone(self)
end end
end end
if annunc.EmergencyCoolant > 1 and self.emcool_opened then if annunc.EmergencyCoolant > 1 and self.em_cool_opened then
log.info(util.c("UNIT ", self.r_id, " emergency coolant valve closed")) log.info(util.c("UNIT ", self.r_id, " emergency coolant valve closed"))
log.info(util.c("UNIT ", self.r_id, " turbines set to not dump steam")) log.info(util.c("UNIT ", self.r_id, " turbines set to not dump steam"))
end end
self.emcool_opened = false self.em_cool_opened = false
elseif enable_emer_cool or self.emcool_opened then elseif enable_emer_cool or self.em_cool_opened then
-- set turbines to dump excess steam -- set turbines to dump excess steam
for i = 1, #self.turbines do for i = 1, #self.turbines do
local session = self.turbines[i] local session = self.turbines[i]
@ -938,16 +954,33 @@ function logic.handle_redstone(self)
end end
end end
if annunc.EmergencyCoolant > 1 and not self.emcool_opened then if annunc.EmergencyCoolant > 1 and not self.em_cool_opened then
log.info(util.c("UNIT ", self.r_id, " emergency coolant valve opened")) log.info(util.c("UNIT ", self.r_id, " emergency coolant valve opened"))
log.info(util.c("UNIT ", self.r_id, " turbines set to dump excess steam")) log.info(util.c("UNIT ", self.r_id, " turbines set to dump excess steam"))
end end
self.emcool_opened = true self.em_cool_opened = true
end end
-- set valve state always -- set valve state always
if self.emcool_opened then self.valves.emer_cool.open() else self.valves.emer_cool.close() end if self.em_cool_opened then self.valves.emer_cool.open() else self.valves.emer_cool.close() end
-----------------------
-- Auxiliary Coolant --
-----------------------
if self.aux_coolant then
if self.enable_aux_cool and (not self.aux_cool_opened) then
log.info(util.c("UNIT ", self.r_id, " auxiliary coolant valve opened"))
self.aux_cool_opened = true
elseif (not self.enable_aux_cool) and self.aux_cool_opened then
log.info(util.c("UNIT ", self.r_id, " auxiliary coolant valve closed"))
self.aux_cool_opened = false
end
-- set valve state always
if self.aux_cool_opened then self.valves.aux_cool.open() else self.valves.aux_cool.close() end
end
end end
return logic return logic