> Page is a work in progress
|
|
||||||
|
|
||||||
# Coolant and Waste Valve and Flow Screen
|
# Coolant and Waste Valve and Flow Screen
|
||||||
|
|
||||||
1. [Valve Brief](#valve-brief)
|
1. [Valve Brief](#valve-brief)
|
||||||
@ -45,8 +43,6 @@ The steam relief valves that the turbines have have a hashed icon to the right o
|
|||||||
|
|
||||||
The cooling loop display is reminiscent of the main unit overview on the main view screen, as it shows the reactor, the boilers, and the turbines. Due to space constraints, 1 to 2 boilers are displayed as one block, and the 1 to 3 turbines are displayed as another single block. For all the pipes flow rates, when there is more than device involved, the sum of all of those values is indicated. For example, if there are three turbines, the flow rate of water return is the sum of the flow rates of all three turbines.
|
The cooling loop display is reminiscent of the main unit overview on the main view screen, as it shows the reactor, the boilers, and the turbines. Due to space constraints, 1 to 2 boilers are displayed as one block, and the 1 to 3 turbines are displayed as another single block. For all the pipes flow rates, when there is more than device involved, the sum of all of those values is indicated. For example, if there are three turbines, the flow rate of water return is the sum of the flow rates of all three turbines.
|
||||||
|
|
||||||
> Note that in setups with one turbine, it will say "STEAM TURBINE GENERATOR", and in setups with two or three, it will say "STEAM TURBINE GENERATORS"
|
|
||||||
|
|
||||||
To assist in indicating the direction of flow, the blocks in the cooling loop contain arrow markings where pipes originate to indicate flow direction.
|
To assist in indicating the direction of flow, the blocks in the cooling loop contain arrow markings where pipes originate to indicate flow direction.
|
||||||
|
|
||||||
#### Water / Steam Loop
|
#### Water / Steam Loop
|
||||||
@ -85,6 +81,10 @@ The dynamic tanks on the screen begin with a status tag, similar to other blocks
|
|||||||
|
|
||||||
### Emergency Coolant Valves
|
### Emergency Coolant Valves
|
||||||
|
|
||||||
|
<img width="236" alt="image" src="https://github.com/MikaylaFischler/cc-mek-scada/assets/2926271/dcd565db-3796-4842-8d70-861ed103ba5b">
|
||||||
|
|
||||||
|
Emergency coolant valves enable flow from dynamic tanks to the water supply in a reactor cooling loop. Flow should be entering at the point of water return from the turbine(s), which then routes back into either the reactor or the boiler, depending on cooling type. The valves identifiers are as follows: unit 1 = `PV05-EMC`, unit 2 = `PV10-EMC`, unit 3 = `PV15-EMC`, and unit 4 = `PV20-EMC`.
|
||||||
|
|
||||||
## Waste Processing
|
## Waste Processing
|
||||||
|
|
||||||
### Waste Routing Valves and Flow
|
### Waste Routing Valves and Flow
|
||||||
|
|||||||