From 17c9362a2f35ba3eb0daec8754a043e476f09e4c Mon Sep 17 00:00:00 2001 From: Mikayla Date: Sun, 26 Feb 2023 01:44:03 -0500 Subject: [PATCH] Updated System Views (markdown) --- System-Views.md | 29 ++++++++++++++++++++++++++--- 1 file changed, 26 insertions(+), 3 deletions(-) diff --git a/System-Views.md b/System-Views.md index 7add536..14bbf68 100644 --- a/System-Views.md +++ b/System-Views.md @@ -10,7 +10,7 @@ The top left block in the unit overview is the reactor status. This include the If boilers are in use, the boiler block connects to the reactor and shows its status tag, internal temperature, and boil rate. Four vertical bars show heated coolant fill, water fill, steam fill, and cooled coolant fill (from left to right). -The final block(s) to the right are for the turbines, which show their status tag, power generation rate, and flow rate. +The final block(s) to the right are for the turbines, which show their status tag, power generation rate, and flow rate. A vertical bar shows the steam fill percentage. image @@ -46,13 +46,36 @@ This display dynamically scales based on the number of boilers and turbines. The * ACTIVE (green) → flow rate ≥ 100 mB/t * TRIP (red) → turbine trip (here this only means energy fill is ≥ 99%) -### Process Control +### Facility and Process Control image + +Facility level SCRAM and alarm ACK (ack all alarms for all units) are to the left of the process controls, above the [facility annunciator](https://github.com/MikaylaFischler/cc-mek-scada/wiki/Annunciator-Panels#facility-annunciator-panel). Facility radiation is displayed below, and the count of all connected RTUs is displayed next to that. + image -Facility level SCRAM and alarm ACK (ack all alarms for all units) are to the left of the process controls, above the [facility annunciator](https://github.com/MikaylaFischler/cc-mek-scada/wiki/Annunciator-Panels#facility-annunciator-panel). +The three control target controls are at the top left of the process control. The burn target is a target burn rate that will be split amongst all the assigned units. The total burn rate of all assigned units is shown in the indicator in brown. The charge target is the induction matrix charge level in MFE to attempt to maintain with process control. The current charge of the induction matrix is shown in the indicator in brown. The generation target is the total induction matrix input rate to attempt to maintain. The current induction matrix input is shown in the indicator in brown. The selector for which mode is next to the burn target control. + +* Monitored Max Burn: Run all assigned units at their burn limit. This provides the advantage over manual control of including auto SCRAM safety checks ("Monitored"). +* Combined Burn Rate: Use all assigned units to attempt to meet the Burn Target. +* Charge Level: Use all assigned units to attempt to maintain the Charge Target. +* Generation Rate: Use all assigned units to attempt to maintain the Generation Target. + +All unit limits are below the mode selector. The current burn rates of the units is shown in brown. Unit status indicators are shown to the right, including the ready state (all unit devices are online, OK, not tripped, have builds, have statuses, etc) and the degraded state (unit devices faulted, disconnected, etc). ### Induction Matrix +image + +Most fields here are self-explanatory by their labels. Average charge is over 3 samples, and average inflow/outflows are over 6 samples. The tall vertical bar is charge, then the 'I' bar is input rate capacity and the 'O' bar is output rate capacity. + +#### Induction Matrix Status Tags + +* OFF-LINE (yellow) → matrix disconnected +* NOT FORMED (orange) → matrix not formed +* RTU FAULT (orange) → PPM fault +* ONLINE (green) → matrix connected, charge OK +* LOW CHARGE (yellow) → charge level low (≤ 1%) +* HIGH CHARGE (red) → charge level high (≥ 99%) + ## Unit Detail Views