@ -116,8 +116,25 @@ For all unit status messages, see the status message page.
|
||||
|
||||
This region includes reactor status information and controls. The four bars to the left are the fuel fill, coolant fill, heated coolant fill, and waste fill percentages (from left to right). The commanded burn rate (set burn rate) and burn rate (actual burn rate, which is 0 if inactive) are shown separately. If an environment detector is connected and assigned to this unit, the radiation level is shown here.
|
||||
|
||||
When not in auto control mode, the burn rate can be set manually by the operator using the spinbox control then pressing SET.
|
||||
When set to manual control (in auto control assignment), the burn rate can be set manually by the operator using the spinbox control then pressing SET.
|
||||
|
||||
<img width="500" alt="image" src="https://user-images.githubusercontent.com/2926271/221396809-f92bf634-fab9-4848-8479-a43b0e91821b.png">
|
||||
|
||||
The START and RESET buttons enable/disable depending on state. For example, if the reactor is running or in auto control, the start button is disabled (cannot be pressed, turns gray). If the RPS is tripped, the RESET button is enabled (can be pressed). The SCRAM and ACK buttons can always be pressed. SCRAM will trigger a manual RPS trip. ACK will acknowledge (mute) all [alarms](https://github.com/MikaylaFischler/cc-mek-scada/wiki/Alarms) for just this unit.
|
||||
|
||||
### Auto Control Assignment
|
||||
|
||||
<img width="142" alt="image" src="https://user-images.githubusercontent.com/2926271/221397090-a5fb3f1d-dd25-4f4f-9e2d-c11bd373daf2.png">
|
||||
|
||||
This panel is used to assign a unit to auto control groups. "Manual" allows for manual control of start/stop and the burn rate. All other modes lock out that operation and allow for auto process control of this unit. Press SET to change this mode, but this cannot be done if the reactor is actively running in auto mode. "Prio. Group" shows the acknowledged state of the control, which means it shows what the supervisor thinks its assignment is. "Ready" indicates if all unit devices are ready for auto control (not tripped, online, not faulted, has builds, has statuses, etc). "Standby" blinks white if the reactor is not active at the moment but it is part of a running process control loop.
|
||||
|
||||
### Waste Processing Routing
|
||||
|
||||
<img width="333" alt="image" src="https://user-images.githubusercontent.com/2926271/221397212-c12267d7-6df5-4dd7-9e10-d91599e8b19c.png">
|
||||
|
||||
Depending on redstone connections, this allows routing reactor waste to different production systems.
|
||||
|
||||
* Auto: NOT IMPLEMENTED YET
|
||||
* Pu: Plutonium pellet production
|
||||
* Po: Polonium pellet production
|
||||
* AM: Antimatter production
|
||||
|
||||