From 2eb7f3bdc25b1c3075062012b5dc3dcf4ca98fa6 Mon Sep 17 00:00:00 2001 From: Mikayla Date: Sat, 20 Apr 2024 13:46:39 -0400 Subject: [PATCH] Updated System Setup (markdown) --- System-Setup.md | 5 ++++- 1 file changed, 4 insertions(+), 1 deletion(-) diff --git a/System-Setup.md b/System-Setup.md index 0983285..c6ff927 100644 --- a/System-Setup.md +++ b/System-Setup.md @@ -48,9 +48,12 @@ Each computer requires one wireless (Ender) modem, not listed below. | Type | For | Quantity | Purpose | | --- | --- | --- | --- | | Advanced Computer | Coordinator | 1 | Run the graphical user interface for controlling and monitoring the system. | -| Advanced Monitors | Coordinator | 3+ | Provide the graphical user interface for controlling and monitoring the system. | +| Advanced Monitor | Coordinator | 3+ | Provide the graphical user interface for controlling and monitoring the system. Note: 3+ means 3+ assembled multi-blocks, which requires many more than 3 blocks. | | Speaker | Coordinator | 1 | Play alarm tones in the control room. | | Advanced Computer | Supervisor | 1 | Connect to all computers and manage the system with and without Coordinator instructions. | +| Advanced Computer | Reactor PLC | 1-4 | Interface with a single Fission Reactor and enforce safe operation. | +| Advanced Computer | RTU Gateway | 1+ | Connect to all other machines (besides the Fission Reactor) to the system and provide access to them to the Supervisor. | +| Speaker | RTU | 0+ | Play alarm tones elsewhere outside the control room. | ### Coordinator Displays