Updated System Setup (markdown)
parent
2eb7f3bdc2
commit
7c10c9d4d3
@ -48,13 +48,26 @@ Each computer requires one wireless (Ender) modem, not listed below.
|
|||||||
| Type | For | Quantity | Purpose |
|
| Type | For | Quantity | Purpose |
|
||||||
| --- | --- | --- | --- |
|
| --- | --- | --- | --- |
|
||||||
| Advanced Computer | Coordinator | 1 | Run the graphical user interface for controlling and monitoring the system. |
|
| Advanced Computer | Coordinator | 1 | Run the graphical user interface for controlling and monitoring the system. |
|
||||||
| Advanced Monitor | Coordinator | 3+ | Provide the graphical user interface for controlling and monitoring the system. Note: 3+ means 3+ assembled multi-blocks, which requires many more than 3 blocks. |
|
| Advanced Monitor | Coordinator | 3-6 | Provide the graphical user interface for controlling and monitoring the system. Note: 3-6 refers to assembled multi-blocks, which requires many more than 3-6 blocks. |
|
||||||
| Speaker | Coordinator | 1 | Play alarm tones in the control room. |
|
| Speaker | Coordinator | 1 | Play alarm tones in the control room. |
|
||||||
| Advanced Computer | Supervisor | 1 | Connect to all computers and manage the system with and without Coordinator instructions. |
|
| Advanced Computer | Supervisor | 1 | Connect to all computers and manage the system with and without Coordinator instructions. |
|
||||||
| Advanced Computer | Reactor PLC | 1-4 | Interface with a single Fission Reactor and enforce safe operation. |
|
| Advanced Computer | Reactor PLC | 1-4 | Interface with a single Fission Reactor and enforce safe operation. |
|
||||||
| Advanced Computer | RTU Gateway | 1+ | Connect to all other machines (besides the Fission Reactor) to the system and provide access to them to the Supervisor. |
|
| Advanced Computer | RTU Gateway | 1+ | Connect to all other machines (besides the Fission Reactor) to the system and provide access to them to the Supervisor. |
|
||||||
| Speaker | RTU | 0+ | Play alarm tones elsewhere outside the control room. |
|
| Speaker | RTU | 0+ | Play alarm tones elsewhere outside the control room. |
|
||||||
|
|
||||||
|
Below are the other devices supported/required. Quantity refers to per unit or per facility. For example, 1-3 turbines per unit means you can have a total of 12 turbines if you have 4 reactors, since you can have 3 turbines per reactor.
|
||||||
|
|
||||||
|
| Type | For | Quantity | Notes |
|
||||||
|
| --- | --- | --- | --- |
|
||||||
|
| Fission Reactor [Logic Adapter] | Unit | 1 |
|
||||||
|
| Industrial Turbine [Port] | Unit | 1-3 |
|
||||||
|
| Steam Boiler [Port] | Unit | 0-2 |
|
||||||
|
| Solar Neutron Activator | Unit | 0+ |
|
||||||
|
| Supercritical Phase Shifter | Facility | 1 |
|
||||||
|
| Induction Matrix | Facility | 1 |
|
||||||
|
| Environment Detector | Facility | 0+ | From the advanced peripherals mod. |
|
||||||
|
| Environment Detector | Unit | 0+ | From the advanced peripherals mod. |
|
||||||
|
|
||||||
### Coordinator Displays
|
### Coordinator Displays
|
||||||
|
|
||||||
1. There is one main system display, which will need to be the maximum monitor width of 8 monitor blocks. The height depends on the number of units configured, ranging from 4 to 6 blocks (see below table).
|
1. There is one main system display, which will need to be the maximum monitor width of 8 monitor blocks. The height depends on the number of units configured, ranging from 4 to 6 blocks (see below table).
|
||||||
|
|||||||
Loading…
x
Reference in New Issue
Block a user