## Main View ## Main View
## Unit Views ### Unit Overview
<img width="841" alt="image" src="https://user-images.githubusercontent.com/2926271/221394734-56089e71-15fc-4ede-a530-1759c0178be4.png">
The top left block in the unit overview is the reactor status. This include the status tag, core temperature, burn rate, and heating rate. Four horizontal bars show fuel fill, cooled coolant fill, heated coolant fill, and waste fill percentages (from top to bottom).
If boilers are in use, the boiler block connects to the reactor and shows its status tag, internal temperature, and boil rate. Four vertical bars show heated coolant fill, water fill, steam fill, and cooled coolant fill (from left to right).
The final block(s) to the right are for the turbines, which show their status tag, power generation rate, and flow rate.
<img width="748" alt="image" src="https://user-images.githubusercontent.com/2926271/221394890-17429b82-fad5-4b75-9f2f-f36bc13ad24f.png">
This display dynamically scales based on the number of boilers and turbines. The system in general supports a maximum of 2 boilers and 3 turbines, which is the amount of those required to run a max size reactor at the maximum safe burn rate. Examples of water cooled reactors are shown below.
<img width="904" alt="image" src="https://user-images.githubusercontent.com/2926271/221394934-574700af-3f79-4c20-a5ed-defbf36ec8f8.png">
<img width="905" alt="image" src="https://user-images.githubusercontent.com/2926271/221394936-fb27a4f9-9002-487a-b305-ff6d076cfecc.png">
#### Reactor Status Tags
* PLC OFF-LINE (yellow) → reactor PLC disconnected
* NOT FORMED (orange) → reactor not formed
* PLC FAULT (orange) → PPM fault on the reactor PLC
* DISABLED (gray) → reactor disabled, RPS not tripped or tripped manual
* ACTIVE (green) → reactor is running
* SCRAMMED (red) → RPS tripped
* FORCE DISABLED (red) → on servers with meltdowns disabled, the reactor is "force disabled" on meltdown
#### Boiler Status Tags
* OFF-LINE (yellow) → boiler disconnected
* NOT FORMED (orange) → boiler not formed
* RTU FAULT (orange) → PPM fault
* IDLE (gray) → boil rate zero
* ACTIVE (green) → boil rate non-zero
#### Turbine Status Tags
* OFF-LINE (yellow) → turbine disconnected
* NOT FORMED (orange) → turbine not formed
* RTU FAULT (orange) → PPM fault
* IDLE (gray) → flow rate < 100 mB/t
* ACTIVE (green) → flow rate ≥ 100 mB/t
* TRIP (red) → turbine trip
## Unit Detail Views