Updated Mekanism API Notes (markdown)
parent
d8b3300bcb
commit
f7a266776e
@ -1,104 +1 @@
|
||||
Mekanism Computer Integration: https://docs.google.com/spreadsheets/d/1sheh1BIeP_vSto881H6UtgXvxdbyJEfILM_uUW_UD7Q/
|
||||
|
||||
# API Functions for Machines in Use
|
||||
|
||||
## Reactor Logic Port
|
||||
|
||||
* activation
|
||||
* high temperature
|
||||
* excess waste
|
||||
* damage critical (100%+)
|
||||
* insufficient fuel
|
||||
|
||||
Mekanism logic:
|
||||
|
||||
* activate = isPowered() == 1
|
||||
* high temp = getTemperature() >= 1200
|
||||
* excess waste = getWasteNeeded() == 0
|
||||
* damaged = getDamagePercent() >= 100
|
||||
* depleted = getFuelFilledPercentage() == 0
|
||||
|
||||
## Fission Reactor (fissionReactor)
|
||||
|
||||
* getHeatCapacity
|
||||
* getFuelAssemblies
|
||||
* getFuelSurfaceArea
|
||||
* getFuelCapacity
|
||||
* getWasteCapacity
|
||||
* getCoolantCapacity
|
||||
* getHeatedCoolantCapacity
|
||||
* getStatus
|
||||
* getHeatingRate
|
||||
* getTemperature
|
||||
* getDamagePercent
|
||||
* getBoilEfficiency
|
||||
* getEnvironmentalLoss
|
||||
* getFuel
|
||||
* getFuelNeeded
|
||||
* getFuelFilledPercentage
|
||||
* getWaste
|
||||
* getWasteNeeded
|
||||
* getWasteFilledPercentage
|
||||
* getCoolant = ['name': mekanism:sodium, 'amount': 45000000]
|
||||
* getCoolantNeeded
|
||||
* getCoolantFilledPercentage
|
||||
* getHeatedCoolant
|
||||
* getHeatedCoolantNeeded
|
||||
* getHeatedCoolantFilledPercentage
|
||||
* getBurnRate
|
||||
* getActualBurnRate
|
||||
* getMaxBurnRate
|
||||
* scram
|
||||
* setBurnRate
|
||||
* activate
|
||||
|
||||
## Boiler (boiler)
|
||||
|
||||
* getSuperheaters
|
||||
* getBoilCapacity
|
||||
* getSteamCapacity
|
||||
* getWaterCapacity
|
||||
* getHeatedCoolantCapacity
|
||||
* getCooledCoolantCapacity
|
||||
* getTemperature
|
||||
* getEnvironmentalLoss
|
||||
* getBoilRate
|
||||
* getMaxBoilRate
|
||||
* getSteamNeeded
|
||||
* getSteam
|
||||
* getSteamFilledPercentage
|
||||
* getWater
|
||||
* getWaterNeeded
|
||||
* getWaterFilledPercentage
|
||||
* getHeatedCoolant
|
||||
* getHeatedCoolantNeeded
|
||||
* getHeatedCoolantFilledPercentage
|
||||
* getCooledCoolant
|
||||
* getCooledCoolantNeeded
|
||||
* getCooledCoolantFilledPercentage
|
||||
|
||||
## Turbine (turbine)
|
||||
|
||||
* getCoils
|
||||
* getBlades
|
||||
* getVents
|
||||
* getDispersers
|
||||
* getCondensers
|
||||
* getDumpingMode
|
||||
* getSteamCapacity
|
||||
* getProductionRate
|
||||
* getMaxProduction
|
||||
* getLastSteamInputRate
|
||||
* getFlowRate
|
||||
* getMaxFlowRate
|
||||
* getMaxWaterOutput
|
||||
* getSteam
|
||||
* getSteamNeeded
|
||||
* getSteamFilledPercentage
|
||||
|
||||
## Induction Matrix (generic mekanismMachine)
|
||||
|
||||
* getTotalEnergyFilledPercentage
|
||||
* getTotalEnergy
|
||||
* getTotalMaxEnergy
|
||||
* getTotalEnergyNeeded
|
||||